Equinoxe

Special Glenosphere Inserter with Rotational Control Feature

Registry build 21.09.26
6manufacturers in China registered for this device type
336catalogue numbers in this listing
4510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (2), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code KWT
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34

Record

Regulatory record for Equinoxe
Listed by Exactech, Inc., United States
FDA product code KWT
Device type Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
Device class Class 2
Regulation 21 CFR 888.3650
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K063569
Record published 2022-08-18
Record revised 2019-08-28 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date, serial number
Sizes Outer diameter 2 to 53 mm; lumen/inner diameter 36 to 46 mm; length 12.5 to 200 mm; angle 8 to 135 °; circumference 6 to 46 mm; height 5 to 15 mm

Catalogue Numbers

Catalogue numbers for Equinoxe
Catalogue number Size Status
321-09-42 Outer Diameter 42 mm In distribution
321-52-33 In distribution
321-45-42 Outer Diameter 42 mm In distribution
308-08-12 Size Extra Small In distribution
315-29-42 In distribution
321-01-20 In distribution
321-50-42 Outer Diameter 42 mm In distribution
315-98-57 In distribution
324-44-10 Angle 135 ° In distribution
300-30-08 Circumference 8 mm In distribution
324-46-00 46mm In distribution
321-01-32 In distribution
315-57-08 In distribution
321-09-10 In distribution
315-31-43 In distribution
315-17-10 In distribution
SPI-009731 In distribution
321-16-35 In distribution
321-01-51 In distribution
301-30-09 Outer Diameter 9 mm In distribution
321-10-35 In distribution
301-16-38 Height 0 In distribution
320-01-42 Outer Diameter 42 mm In distribution
301-10-38 Outer Diameter 38 mm In distribution
331-25-15 EXTRA LARGE In distribution
315-55-13 MEDIUM In distribution
321-03-42 RIGHT In distribution
321-15-09 In distribution
321-03-46 Circumference 46 mm In distribution
314-01-15 extra-large (size) In distribution
315-51-03 MEDIUM In distribution
320-44-03 2.5mm offset In distribution
321-98-00 In distribution
315-29-44 In distribution
320-35-02 10 degree superior augment In distribution
324-10-00 0mm offset In distribution
SPI-009733 In distribution
315-59-09 In distribution
315-54-04 LARGE In distribution
321-07-46 Outer Diameter 46 mm In distribution
321-19-34 In distribution
321-55-38 Outer Diameter 38 mm In distribution
315-98-32 In distribution
SPI-007865 In distribution
315-27-45 In distribution
321-15-00 In distribution
304-21-07 Left In distribution
321-01-29 In distribution
315-31-45 In distribution
315-98-33 In distribution
315-56-03 MEDIUM In distribution
315-52-64 In distribution
320-01-36 Outer Diameter 36 mm In distribution
320-15-10 Low Profile In distribution
315-27-43 In distribution
321-01-31 In distribution
320-55-03 Angle 8 ° In distribution
321-15-07 Outer Diameter 3.2 mm In distribution
301-10-05 In distribution
321-01-10 In distribution
321-17-43 In distribution
315-15-10 In distribution
321-50-38 Outer Diameter 38 mm In distribution
320-15-01 In distribution
SPI-045525 In distribution
321-01-05 In distribution
324-36-10 36mm In distribution
330-46-03 46mm + 2.5mm In distribution
321-50-01 In distribution
321-03-38 Circumference 38 mm In distribution
320-35-04 8 degree posterior augment In distribution
321-15-36 In distribution
310-22-41 Outer Diameter 41 mm In distribution
301-10-53 Outer Diameter 53 mm In distribution
321-98-07 Outer Diameter 46 mm In distribution
321-19-15 In distribution
321-05-38 Outer Diameter 38 mm In distribution
321-15-31 In distribution
331-27-62 In distribution
321-15-06 Outer Diameter 2 mm In distribution
321-19-05 In distribution
324-38-13 38mm In distribution
322-40-03 +2.5mm In distribution
309-07-08 In distribution
305-07-20 In distribution
320-42-00 0mm offset In distribution
330-46-13 46mm + 2.5mm Constrained In distribution
321-98-01 Outer Diameter 38 mm In distribution
322-46-10 Constrained In distribution
321-01-26 In distribution
315-31-42 In distribution
315-05-04 LARGE In distribution
315-55-05 EXTRA LARGE In distribution
321-19-35 In distribution
300-21-45 4.5mm offset In distribution
321-16-66 In distribution
305-21-00 In distribution
SPI-013425 In distribution
320-20-38 Outer Diameter 4.5 mm In distribution
300-21-00 0mm offset In distribution
315-25-12 SMALL In distribution
321-16-06 In distribution
315-52-60 In distribution
SPI-043320 In distribution
SPI-043622 In distribution
320-46-10 constrained In distribution
SPI-044993 In distribution
SPI-006665 In distribution
315-07-04 LARGE In distribution
324-42-10 Constrained In distribution
331-27-02 In distribution
301-99-32 MEDIUM In distribution
321-01-30 In distribution
320-42-03 Lumen/Inner Diameter 42 mm In distribution
321-01-25 In distribution
321-55-01 In distribution
322-42-00 +0mm In distribution
320-20-30 Outer Diameter 4.5 mm In distribution
SPI-040698 In distribution
304-22-13 Outer Diameter 12.5 mm In distribution
321-17-42 In distribution
322-46-00 46mm In distribution
320-55-04 Right In distribution
310-22-47 Outer Diameter 47 mm In distribution
321-98-06 Outer Diameter 42 mm In distribution
321-15-34 In distribution
321-05-46 Outer Diameter 46 mm In distribution
SPI-044393 In distribution
320-20-18 Length 18 mm In distribution
320-31-42 Outer Diameter 42 mm In distribution
320-31-46 Outer Diameter 46 mm In distribution
315-50-03 MEDIUM In distribution
321-01-28 In distribution
322-38-00 38mm In distribution
321-16-05 Height 5 mm In distribution
321-15-05 In distribution
321-15-33 In distribution
SPI-044394 In distribution
321-07-38 Outer Diameter 38 mm In distribution
315-35-11 EXTRA SMALL In distribution
315-26-11 In distribution
321-01-57 In distribution
321-02-42 LEFT In distribution
321-19-11 In distribution
315-59-02 In distribution
320-46-00 0mm offset In distribution
320-42-13 Lumen/Inner Diameter 42 mm In distribution
300-30-10 Circumference 10 mm In distribution
322-44-00 +0mm In distribution
321-35-23 In distribution
310-23-53 Outer Diameter 53 mm In distribution
320-01-38 Outer Diameter 38 mm In distribution
321-15-03 In distribution
320-20-50 Length 50 mm In distribution
320-38-10 constrained In distribution
321-35-00 In distribution
320-31-38 Outer Diameter 38 mm In distribution
301-30-11 Outer Diameter 11 mm In distribution
304-24-07 Outer Diameter 6.5 mm In distribution
SPI-044391 In distribution
321-07-10 In distribution
321-98-02 Outer Diameter 42 mm In distribution
321-07-42 Outer Diameter 42 mm In distribution
301-10-41 Outer Diameter 41 mm In distribution
331-10-30 In distribution
321-17-44 In distribution
320-42-10 constrained In distribution
300-30-14 Circumference 14 mm In distribution
320-38-13 Lumen/Inner Diameter 38 mm In distribution
304-22-11 Right In distribution
315-25-00 In distribution
301-16-37 1.5/4.5 Height In distribution
321-15-13 In distribution
320-20-46 Outer Diameter 4.5 mm In distribution
304-21-11 Left In distribution
321-50-46 In distribution
322-42-13 42mm In distribution
321-05-21 In distribution
320-32-38 Outer Diameter 38 mm In distribution
315-31-44 In distribution
321-02-38 Circumference 38 mm In distribution
321-02-16 In distribution
321-52-67 8, 10, 8/10 Degree In distribution
321-60-46 In distribution
SPI-044392 In distribution
SPI-044440 In distribution
320-10-10 10mm offset In distribution
321-52-07 Outer Diameter 3.2 mm In distribution
321-19-14 In distribution
321-10-40 In distribution
320-15-02 10 degree superior augment In distribution
SPI-040194 In distribution
321-52-66 0 Degree In distribution
321-19-04 In distribution
SPI-047577 In distribution
321-45-38 Outer Diameter 38 mm In distribution
320-55-98 In distribution
315-03-02 In distribution
319-27-00 In distribution
315-37-12 In distribution
321-15-04 In distribution
320-44-13 Constrained In distribution
331-27-05 In distribution
305-99-12 Height 12 mm In distribution
321-98-03 Outer Diameter 46 mm In distribution
322-46-13 Constrained In distribution
321-09-38 Outer Diameter 38 mm In distribution
310-23-47 Outer Diameter 47 mm In distribution
311-07-06 In distribution
320-02-42 Outer Diameter 42 mm In distribution
321-20-00 In distribution
321-35-16 In distribution
321-03-10 In distribution
305-07-20 In distribution
320-35-07 Left In distribution
320-11-38 Outer Diameter 38 mm In distribution
315-45-15 EXTRA LARGE In distribution
301-13-41 Outer Diameter 41 mm In distribution
SPI-040164 In distribution
SPI-046468 In distribution
321-01-33 In distribution
331-25-00 In distribution
321-01-52 In distribution
320-46-13 Lumen/Inner Diameter 46 mm In distribution
331-10-31 In distribution
SPI-005672 In distribution
320-38-00 0mm offset In distribution
321-15-30 In distribution
320-15-04 8 degree posterior augment In distribution
320-40-10 Constrained In distribution
310-23-41 Outer Diameter 41 mm In distribution
321-15-11 In distribution
SPI-005668 In distribution
315-37-12 Angle 8 ° In distribution
315-35-14 LARGE In distribution
320-20-42 Length 42 mm In distribution
SPI-047576 In distribution
310-21-47 Outer Diameter 47 mm In distribution
315-57-17 In distribution
315-29-43 In distribution
331-27-07 In distribution
304-22-07 Right In distribution
315-98-03 MEDIUM In distribution
SPI-040192 In distribution
SPI-045324 In distribution
320-20-00 In distribution
321-02-46 Circumference 46 mm In distribution
310-11-44 short (height) In distribution
321-15-02 In distribution
320-15-05 In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
SMR Shoulder Limacorporate 289
Tornier Perform Humeral System Tornier Inc. 119
Bigliani/Flatow® Zimmer, Inc. 119
Trabecular Metal® Zimmer, Inc. 115
Jarvis Glenoid Rerverse Shoulder Prosthesis Fournitures Hospitalieres Industrie 103
Comprehensive® Shoulder System Biomet Orthopedics 86
Alliance® Zimmer, Inc. 68
Anatomical Shoulder™ Zimmer, Inc. 54
Aetos Shoulder System Smith & Nephew, Inc. 53
Perform™ Humeral System Tornier Inc. 47
Bio-Modular® Shoulder System Biomet Orthopedics 43
Catalyst CSR Shoulder System Catalyst Orthoscience Inc 39

Showing 12 of 164. All products under Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250713 2025-12-01
K162903 2017-02-27
K143659 2015-04-09
K110706 2011-05-17

Recalls Naming This Product

45 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Equinoxe
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Exactech, Inc. 510(k) number 2025-09-05 Class II Release of Material/Component prior to receiving test results Due to products that have not completed design updates and performance testing being released/distributed. Products may not conform to design and performance criteria. 1
Exactech, Inc. 510(k) number 2025-09-05 Class II Release of Material/Component prior to receiving test results Due to products that have not completed design updates and performance testing being released/distributed. Products may not conform to design and performance criteria. 1
Exactech, Inc. 510(k) number 2025-09-05 Class II Release of Material/Component prior to receiving test results Due to products that have not completed design updates and performance testing being released/distributed. Products may not conform to design and performance criteria. 1
Exactech, Inc. 510(k) number 2025-08-15 Class II Process design Reverse Shoulder humeral liners have an articular surface position outside of the dimensional specification within the labeling. 61,334 UNITS
Exactech, Inc. 510(k) number 2025-08-15 Class II Process design Reverse Shoulder humeral liners have an articular surface position outside of the dimensional specification within the labeling. 11,542 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 2077 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 2008 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 6678 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 6840 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 11031 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 12643 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 3436 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 4007 units
Exactech, Inc. UDI-DI 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 11863 units
Exactech, Inc. UDI-DI 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 826 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 66646 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 7213 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 2806 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 447 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 24303 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 3648 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 1970 units
Exactech, Inc. 510(k) number 2024-03-06 Class II Nonconforming Material/Component The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer cons 591 units
Exactech, Inc. 510(k) number 2023-11-21 Class II Packaging change control Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.
Exactech, Inc. 510(k) number 2021-05-11 Class II Device Design The HAT trial contains a retaining ring that has shown the potential to disengage during use. 36 devices
Exactech, Inc. 510(k) number 2020-11-09 Class II Employee error Potential for incorrect Instructions For Use (IFU) included with an Equinoxe Humeral Stem, Primary, Press Fit, 11mm package. 14 devices
Exactech, Inc. 510(k) number 2020-10-06 Class II Packaging process control The product may be mislabeled. 69 devices 2023-11-13
Exactech, Inc. 510(k) number 2020-10-06 Class II Packaging process control The product may be mislabeled. 40 devices 2023-11-13
Exactech, Inc. 510(k) number 2020-09-25 Class II Process control The device may be incorrectly laser marked as a right stem, when it should have been laser marked as a left stem. 25 devices 2023-05-01
Exactech, Inc. 510(k) number 2020-09-25 Class II Process control The device may be incorrectly laser marked as a right stem, when it should have been laser marked as a left stem. 12 devices 2023-05-01
Exactech, Inc. 510(k) number 2020-08-24 Class II Labeling Change Control Exactech is recalling the Equinoxe Reverse Shoulder Compression Screw/Locking Cap Kit, because it may contain a incorrect length screw. 125 devices 2023-05-01
Exactech, Inc. 510(k) number 2020-08-24 Class II Labeling Change Control Exactech is recalling the Equinoxe Reverse Shoulder Compression Screw/Locking Cap Kit, because it may contain a incorrect length screw. 149 devices 2023-05-01
Exactech, Inc. 510(k) number 2019-12-03 Class II Under Investigation by firm Labels with incorrect translations were identified by Exactech is a distributor in the Netherlands. The translations on the outer labels include the word ” long” in all languages other than the original English version. The implants are 2,910 devices 2022-10-11
Exactech, Inc. 510(k) number 2019-12-03 Class II Under Investigation by firm Labels with incorrect translations were identified by Exactech is a distributor in the Netherlands. The translations on the outer labels include the word ” long” in all languages other than the original English version. The implants are 2022-10-11
Exactech, Inc. 510(k) number 2018-12-05 Class II Packaging Possibility that the Equinoxe Preserve Humeral Stem, 8mm, was inadvertently packaged with an Optetrak Knee System instructions for use (IFU) rather than the Equinoxe Preserve Humeral Stem IFU as intended. 40 devices 2021-04-29
Exactech, Inc. 510(k) number 2018-08-21 Class II Under Investigation by firm The Equinoxe Reverse Drill Bit Kits may contain two 2mm diameter drill bits instead of one 2mm diameter drill bit and one 3.2mm diameter drill bit as intended. 2 units
Exactech, Inc. 510(k) number 2017-08-31 Class II Under Investigation by firm Potentially mislabeled. 30 2019-08-06
Exactech, Inc. 510(k) number 2017-08-31 Class II Under Investigation by firm Potentially mislabeled. 30 2019-08-06
Exactech, Inc. 510(k) number 2016-10-25 Class II Component design/selection Disengaged screw head could potentially not be retained in the Torque Defining Screwdriver. 2,278 units 2019-07-26
Exactech, Inc. 510(k) number 2015-02-13 Class II Labeling mix-ups Incorrectly packaged. Outer and inner labeling may incorrectly identify the size of the enclosed device. 112 devices 2016-09-29

Showing 40 of 45.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer