Acumatch a Series
11 catalogue numbers from 144-32-10, listed by Exactech, Inc., United States, under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (2), Zhejiang (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Exactech, Inc., United States |
|---|---|
| FDA product code | KWZ |
| Device type | Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3310 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K040601 |
| Record published | 2015-08-10 |
| Record revised | 2025-08-28 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | expiry date, serial number |
| Sizes | Outer diameter 32 mm |
| Distribution end date | 2024-06-13 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 144-32-10 | Size K | Withdrawn |
| 144-02-08 | Size H | Withdrawn |
| 144-02-09 | Size J | Withdrawn |
| 144-32-07 | Size G | Withdrawn |
| 144-02-07 | Size G | Withdrawn |
| 144-02-06 | Size F | Withdrawn |
| 144-32-08 | Size H | Withdrawn |
| 144-02-10 | Size K | Withdrawn |
| 144-32-05 | Size E | Withdrawn |
| 144-32-06 | Size F | Withdrawn |
| 144-32-09 | Size J | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DJO Surgical | Encore Medical, L.P. | 159 |
| Instrument | Howmedica Osteonics Corp | 139 |
| ZMR® | Zimmer, Inc. | 103 |
| Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer | Zimmer, Inc. | 69 |
| Arcos Modular Revision System | Biomet Orthopedics | 66 |
| Pinnacle | Depuy Orthopaedics, Inc. | 52 |
| System 12 | Howmedica Osteonics Corp | 47 |
| Restoration | Howmedica Osteonics Corp | 46 |
| Redapt | Smith & Nephew, Inc. | 43 |
| R3 | Smith & Nephew, Inc. | 41 |
| Trident | Howmedica Osteonics Corp | 38 |
| Arcos Modular Revision Hip System | Biomet Orthopedics | 37 |
Showing 12 of 165. All products under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K071676 | 2007-07-19 |
| K040601 | 2004-10-04 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Exactech, Inc. | 510(k) number | 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 1017 devices |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2023-11-21 | Class II | Packaging change control | Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag. | |
| 2022-08-11 | Class II | Process control | Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. | 2319 devices |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P960054 | 1997-06-19 | S-ROM POLY-DIAL CONSTRAINED LINER | Depuy, A Johnson & Johnson Co. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.