Omnifit

Acetabular Cup

Registry build 21.09.26
10manufacturers in China registered for this device type
21catalogue numbers in this listing
4510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (2), Zhejiang (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWZ
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Omnifit
Listed by Howmedica Osteonics Corp, United States
FDA product code KWZ
Device type Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3310
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
510(k) K803192
Record published 2015-09-24
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Lumen/inner diameter 22 to 32 mm; outer diameter 40 to 61 mm

Catalogue Numbers

Catalogue numbers for Omnifit
Catalogue number Size Status
61-2861 Lumen/Inner Diameter 28.0 mm In distribution
61-2852 Outer Diameter 52.0 mm In distribution
61-2252 Outer Diameter 52.0 mm In distribution
61-3258 Outer Diameter 58.0 mm In distribution
61-3256 Lumen/Inner Diameter 32.0 mm In distribution
61-2858 Lumen/Inner Diameter 28.0 mm In distribution
61-2261 Lumen/Inner Diameter 22.0 mm In distribution
61-3252 Lumen/Inner Diameter 32.0 mm In distribution
61-3254 Lumen/Inner Diameter 32.0 mm In distribution
61-2856 Outer Diameter 56.0 mm In distribution
61-3248 Lumen/Inner Diameter 32.0 mm In distribution
61-2244 Lumen/Inner Diameter 22.0 mm In distribution
61-2240 Lumen/Inner Diameter 22.0 mm In distribution
61-2248 Outer Diameter 48.0 mm In distribution
61-2854 Outer Diameter 54.0 mm In distribution
61-2846 Outer Diameter 46.0 mm In distribution
61-3261 Outer Diameter 61.0 mm In distribution
61-2844 Outer Diameter 44.0 mm In distribution
61-2848 Outer Diameter 48.0 mm In distribution
61-2850 Lumen/Inner Diameter 28.0 mm In distribution
61-2256 Lumen/Inner Diameter 22.0 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
DJO Surgical Encore Medical, L.P. 159
Instrument Howmedica Osteonics Corp 139
ZMR® Zimmer, Inc. 103
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer Zimmer, Inc. 69
Arcos Modular Revision System Biomet Orthopedics 66
Pinnacle Depuy Orthopaedics, Inc. 52
System 12 Howmedica Osteonics Corp 47
Restoration Howmedica Osteonics Corp 46
Redapt Smith & Nephew, Inc. 43
R3 Smith & Nephew, Inc. 41
Trident Howmedica Osteonics Corp 38
Arcos Modular Revision Hip System Biomet Orthopedics 37

Showing 12 of 165. All products under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K063445 2007-03-08
K063550 2007-03-08
K063552 2007-03-08
K061654 2006-07-07

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Omnifit
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Howmedica Osteonics Corp UDI-DI 2026-07-30 Not classified Process change control Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to 12,156 US

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P960054 1997-06-19 S-ROM POLY-DIAL CONSTRAINED LINER Depuy, A Johnson & Johnson Co.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer