Ringloc RX90-2 HIP System
26 catalogue numbers from 11-105963, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (5), Shanghai (2), Zhejiang (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Lincotek (Wuxi) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 7 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | KWZ |
| Device type | Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3310 |
| 510(k) | K042989 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 11-105963 | 32MM HEAD SIZE 43 LINER SIZE | In distribution |
| 11-105973 | 32MM HEAD SIZE 43 LINER SIZE | In distribution |
| 11-105967 | 32MM HEAD SIZE 47 LINER SIZE | In distribution |
| XL-129072 | 32MM HEAD SIZE 42 LINER SIZE | In distribution |
| 11-105977 | 32mm Head Size 47 Liner Size | In distribution |
| 11-105968 | 32MM HEAD SIZE 48 LINER SIZE | In distribution |
| 11-105954 | 28MM HEAD SIZE 44 LINER SIZE | In distribution |
| XL-129052 | 28MM HEAD SIZE 42 LINER SIZE | In distribution |
| 11-105964 | 32mm Head Size 44 Liner Size | In distribution |
| XL-104947 | 28mm Head Size 47 Liner Size | In distribution |
| 11-105974 | 32MM HEAD SIZE 44 LINER SIZE | In distribution |
| 12-105933 | 28MM HEAD SIZE 43 LINER SIZE | In distribution |
| 12-105938 | 28MM HEAD SIZE 48 LINER SIZE | In distribution |
| 11-105946 | 28MM HEAD SIZE 46 LINER SIZE | In distribution |
| XL-106954 | 28mm Head Size 44 Liner Size | In distribution |
| 11-105953 | 28mm Head Size 43 Liner Size | In distribution |
| 11-105975 | 32mm Head Size 45 Liner Size | In distribution |
| XL-104943 | 28MM HEAD SIZE 43 LINER SIZE | In distribution |
| 10-129057 | 28MM HEAD SIZE 47 LINER SIZE | In distribution |
| 11-105944 | 28mm Head Size 44 Liner Size | In distribution |
| XL-129055 | 28mm Head Size 45 Liner Size | In distribution |
| 11-105958 | 28MM HEAD SIZE 48 LINER SIZE | In distribution |
| 12-105946 | 32MM HEAD SIZE 46 LINER SIZE | In distribution |
| XL-129078 | 32MM HEAD SIZE 48 LINER SIZE | In distribution |
| XL-104941 | 28MM HEAD SIZE 41 LINER SIZE | In distribution |
| 11-105958 | 28mm Head Size 48 Liner Size | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DJO Surgical | Encore Medical, L.P. | 159 |
| Instrument | Howmedica Osteonics Corp | 139 |
| ZMR® | Zimmer, Inc. | 103 |
| Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer | Zimmer, Inc. | 69 |
| Arcos Modular Revision System | Biomet Orthopedics | 66 |
| Pinnacle | Depuy Orthopaedics, Inc. | 52 |
| System 12 | Howmedica Osteonics Corp | 47 |
| Restoration | Howmedica Osteonics Corp | 46 |
| Redapt | Smith & Nephew, Inc. | 43 |
| R3 | Smith & Nephew, Inc. | 41 |
| Trident | Howmedica Osteonics Corp | 38 |
| Arcos Modular Revision Hip System | Biomet Orthopedics | 37 |
Showing 12 of 165. All products under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K021661 | 2002-10-25 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2017-02-17 | Class II | Process design | Endotoxin levels higher than process maximum limits were discovered in the identified polyethylene components. | 28,253 in total | 2018-01-29 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P960054 | 1997-06-19 | S-ROM POLY-DIAL CONSTRAINED LINER | Depuy, A Johnson & Johnson Co. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.