Z1™ Hip System

24 catalogue numbers from 611102120, listed by Zimmer, Inc., United States, under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer. 10 manufacturers in China are registered for this product code.

Registry build 21.09.26
10manufacturers in China registered for this device type
24catalogue numbers in this listing
4510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (2), Zhejiang (2). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code KWZ
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Z1™ Hip System
Listed by Zimmer, Inc., United States
FDA product code KWZ
Device type Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3310
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K233476
Record published 2024-09-09
Record revised 2026-02-04 (version 2)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Z1™ Hip System
Catalogue number Size Status
611102120 Size 12 In distribution
611103050 Size 5 In distribution
611203050 Size 5 In distribution
611201030 Size 3 In distribution
611201040 Size 4 In distribution
611203000 Size 0 In distribution
611203070 Size 7 In distribution
611102010 Size 1 In distribution
611103100 Size 10 In distribution
611889010 Size 1 In distribution
611101030 Size 3 In distribution
611201080 Size 8 In distribution
611202050 Size 5 In distribution
612201040 Size 4 In distribution
611202060 Size 6 In distribution
611889080 Size 8 In distribution
611201090 Size 9 In distribution
612102030 Size 3 In distribution
611103110 Size 11 In distribution
611777240 Size 10-12 Long In distribution
611103020 Size 2 In distribution
612202120 Size 12 In distribution
611203060 Size 6 In distribution
611201050 Size 5 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
DJO Surgical Encore Medical, L.P. 159
Instrument Howmedica Osteonics Corp 139
ZMR® Zimmer, Inc. 103
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer Zimmer, Inc. 69
Arcos Modular Revision System Biomet Orthopedics 66
Pinnacle Depuy Orthopaedics, Inc. 52
System 12 Howmedica Osteonics Corp 47
Restoration Howmedica Osteonics Corp 46
Redapt Smith & Nephew, Inc. 43
R3 Smith & Nephew, Inc. 41
Trident Howmedica Osteonics Corp 38
Arcos Modular Revision Hip System Biomet Orthopedics 37

Showing 12 of 165. All products under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K101730 2010-12-03
K072121 2008-01-07
K071718 2007-07-13
K021826 2002-12-20

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Z1™ Hip System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Zimmer, Inc. 510(k) number 2025-02-12 Class II Under Investigation by firm There is a potential design issue with the Z1 Offset Stem Inserter leading to fracturing of the distal tip. 35 units

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2012-08-27 Class II Labeling Change Control Trilogy Longevity Constrained Liner devices were packaged in incorrect cartons. The product is packaged in the incorrect carton. Product labels and patient labels are correct, matching the product inside the carton. 1 2013-08-27

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P960054 1997-06-19 S-ROM POLY-DIAL CONSTRAINED LINER Depuy, A Johnson & Johnson Co.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer