Profemur®
"profemur® R" Grit Blasted Prox Body STD 1 V4
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (2), Zhejiang (2). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Microport Orthopedics Inc., United States |
|---|---|
| FDA product code | LWJ |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3360 |
| Establishment | Contract manufacturer, Reprocessor, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2015-10-20 |
| Record revised | 2018-03-29 (version 2) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Sizes | Length 135 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PPW39102 | In distribution | |
| PPW39104 | In distribution | |
| PHAC1232 | In distribution | |
| PRTL0023 | In distribution | |
| PRTL0029 | In distribution | |
| PPW39110 | In distribution | |
| PRTL0025 | In distribution | |
| PRTL0027 | In distribution | |
| PPW39112 | In distribution | |
| PHAC1242 | In distribution | |
| PRTL0021 | In distribution | |
| PRTL0031 | In distribution | |
| PPW39108 | In distribution | |
| PPW38000 | Length 135 mm | In distribution |
| PPW38058 | In distribution | |
| PPW39106 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Iconacy i-Hip | Iconacy Orthopedic Implants, LLC | 154 |
| ZMR® | Zimmer, Inc. | 129 |
| Instrument | Howmedica Osteonics Corp | 120 |
| Restoration | Howmedica Osteonics Corp | 66 |
| U2 Hip Stem | United Orthopedic Corp. | 60 |
| Trinity Acetabular Hip System | Corin Limited | 58 |
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented | Exactech, Inc. | 51 |
| Omnifit | Howmedica Osteonics Corp | 48 |
| Novation | Exactech, Inc. | 48 |
| Endo-Model SL Knee Prosthesis System | Waldemar Link GmbH & Co. KG | 46 |
| Trident | Howmedica Osteonics Corp | 43 |
| Kinectiv® | Zimmer, Inc. | 41 |
Showing 12 of 131. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
Recalls
2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2020-07-31 | Class I | Device Design | MicroPort Orthopedics Inc. states that there have been reports of fractures of the long and extra-long Titanium modular femoral neck component after implantation. Worldwide there were 680 Long and X-Long PROFEMUR Titanium modular neck frac | 556 units | 2024-04-16 |
| 2020-07-31 | Class II | Labeling Change Control | MicroPort Orthopedics Inc. is voluntarily recalling any existing inventory of PROFEMUR Titanium and Cobalt Chrome modular necks with previous package insert versions to replace the PROFEMUR Hip System Package Insert with the most recent rev | 12,348 units | |
| 2020-07-31 | Class I | Device Design | MicroPort Orthopedics Inc. states that there have been reports of fractures of the long and extra-long Titanium modular femoral neck component after implantation. Worldwide there were 680 Long and X-Long PROFEMUR Titanium modular neck frac | 123,284 units | 2024-04-16 |
| 2016-06-30 | Class II | Error in labeling | Profemur(R) neck, Item Number PHA01222 (Short AR VV2 Ti Neck) was labeled as Item Number PHA01212 (Short AR VV1 Ti Neck). | 14 units | 2017-01-21 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.