Screw
2 catalogue numbers from 6290-7-065, listed by Howmedica Osteonics Corp, United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (2), Zhejiang (2). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Howmedica Osteonics Corp, United States |
|---|---|
| FDA product code | LWJ |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3360 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Manufacturer |
| Record published | 2015-09-24 |
| Record revised | 2025-02-06 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Sizes | Length 12 to 65 mm |
| Distribution end date | 2019-09-19 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 6290-7-065 | Diameter: 6.2 Millimeter | In distribution |
| 6290-7-012 | Length 12.0 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Iconacy i-Hip | Iconacy Orthopedic Implants, LLC | 154 |
| ZMR® | Zimmer, Inc. | 129 |
| Instrument | Howmedica Osteonics Corp | 120 |
| Restoration | Howmedica Osteonics Corp | 66 |
| U2 Hip Stem | United Orthopedic Corp. | 60 |
| Trinity Acetabular Hip System | Corin Limited | 58 |
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented | Exactech, Inc. | 51 |
| Omnifit | Howmedica Osteonics Corp | 48 |
| Novation | Exactech, Inc. | 48 |
| Endo-Model SL Knee Prosthesis System | Waldemar Link GmbH & Co. KG | 46 |
| Trident | Howmedica Osteonics Corp | 43 |
| Kinectiv® | Zimmer, Inc. | 41 |
Showing 12 of 131. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K023692 | 2003-03-20 |
| K993601 | 1999-11-16 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2023-12-01 | Class II | Nonconforming Material/Component | Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties. | ||
| 2023-12-01 | Class II | Nonconforming Material/Component | Product manufactured using UHMWPE raw material over 5 years of age has the potential for elevated levels of oxidation. Oxidation within UHMWPE can have an impact on its material properties. | ||
| 2009-06-18 | Not classified | Process control | Sterilization issue: During post-sterilization inspection of the outer blister packaging of the affected lots, it was determined that the outer blister did not meet the required minimum seal width. | 13 total, both products. | 2012-08-27 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.