Z1™ Hip System
17 catalogue numbers from 611202040, listed by Zimmer, Inc., United States, under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (2), Zhejiang (2). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Xian Airfoil Technology Co., Ltd. | Xian | Shaanxi | Contract manufacturer | 8 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
Record
| Listed by | Zimmer, Inc., United States |
|---|---|
| FDA product code | LWJ |
| Device type | Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3360 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K233476 |
| Record published | 2024-09-09 |
| Record revised | 2026-02-04 (version 2) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 611202040 | Size 4 | In distribution |
| 612202020 | Size 2 | In distribution |
| 611889110 | Size 11 | In distribution |
| 611101060 | Size 6 | In distribution |
| 611889100 | Size 10 | In distribution |
| 612101050 | Size 5 | In distribution |
| 611777612 | In distribution | |
| 611103030 | Size 3 | In distribution |
| 611202070 | Size 7 | In distribution |
| 611203110 | Size 11 | In distribution |
| 611201110 | Size 11 | In distribution |
| 612202030 | Size 3 | In distribution |
| 611103060 | Size 6 | In distribution |
| 611777220 | Size 0-9 Short | In distribution |
| 611203010 | Size 1 | In distribution |
| 611102050 | Size 5 | In distribution |
| 611202020 | Size 2 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Iconacy i-Hip | Iconacy Orthopedic Implants, LLC | 154 |
| ZMR® | Zimmer, Inc. | 129 |
| Instrument | Howmedica Osteonics Corp | 120 |
| Restoration | Howmedica Osteonics Corp | 66 |
| U2 Hip Stem | United Orthopedic Corp. | 60 |
| Trinity Acetabular Hip System | Corin Limited | 58 |
| Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented | Exactech, Inc. | 51 |
| Omnifit | Howmedica Osteonics Corp | 48 |
| Novation | Exactech, Inc. | 48 |
| Endo-Model SL Knee Prosthesis System | Waldemar Link GmbH & Co. KG | 46 |
| Trident | Howmedica Osteonics Corp | 43 |
| Kinectiv® | Zimmer, Inc. | 41 |
Showing 12 of 131. All products under Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K961378 | 1996-10-08 |
| K952776 | 1996-02-14 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Zimmer, Inc. | 510(k) number | 2025-02-12 | Class II | Under Investigation by firm | There is a potential design issue with the Z1 Offset Stem Inserter leading to fracturing of the distal tip. | 35 units |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-10-11 | Class II | Packaging | Zimmer recently conducted a review of all historic packaging validations at its Zimmer Manufacturing B.V. (ZMBV) facility in Ponce, Puerto Rico. Based on this review, it was determined that the packaging operations conducted in the Building | 7,044,680 total | 2017-04-14 |
| 2009-05-15 | Not classified | Process control | The threads on the screw are incomplete/non-functional. | 10 | 2009-11-12 |
| 2006-08-02 | Not classified | Other | Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. | 181 of all devices | 2007-05-04 |
| 2006-08-02 | Not classified | Other | Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. | 181 of all devices | 2007-05-04 |
| 2006-08-02 | Not classified | Other | Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. | 181 of all devices | 2007-05-04 |
| 2006-08-02 | Not classified | Other | Lack of assurance of proper metal fatigue strength due to a metal grain structure anomaly. | 181 of all devices | 2007-05-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.