Novation

Tapered Reamer, Zimmer Hudson, Novation 3°, Size 15

Registry build 21.09.26
14manufacturers in China registered for this device type
317catalogue numbers in this listing
8510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MEH
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Record

Regulatory record for Novation
Listed by Exactech, Inc., United States
FDA product code MEH
Device type Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K070479
Record published 2015-08-10
Record revised 2025-09-03 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number
Sizes Outer diameter 40 to 68 mm; length 115 to 190 mm; lumen/inner diameter 22 to 40 mm; angle 3 °
Distribution end date 2024-06-13

Catalogue Numbers

Catalogue numbers for Novation
Catalogue number Size Status
180-12-52 Group 2 In distribution
167-00-04 In distribution
160-20-18 Standard Offset In distribution
160-30-10 Standard Offset In distribution
160-21-14 Extended Offset In distribution
180-01-40 Group 00 In distribution
160-00-14 Standard Offset In distribution
138-32-53 10 degree face changing In distribution
180-10-54 Group 2 In distribution
180-10-58 Group 3 In distribution
160-20-17 Standard Offset In distribution
160-20-16 Standard Offset In distribution
160-01-18 Extended Offset In distribution
138-22-70 10 degree face changing In distribution
130-32-44 Size Group 4 In distribution
160-21-12 Extended Offset In distribution
160-32-15 STD OFFSET In distribution
180-03-62 Group 4 In distribution
180-10-64 Group 5 In distribution
180-13-66 Group 5 In distribution
167-00-02 In distribution
180-11-40 Group 00 In distribution
160-23-13 EXT OFFSET In distribution
180-12-64 Group 5 In distribution
180-14-54 Group 3 In distribution
180-00-64 Group 5 In distribution
160-21-13 Extended Offset In distribution
180-01-48 Group 1 In distribution
167-00-03 In distribution
164-02-15 Extended Offset In distribution
164-02-14 Extended Offset In distribution
164-11-11 Standard Offset In distribution
164-01-17 Standard Offset In distribution
160-11-15 Extended Offset In distribution
180-03-52 Group 2 In distribution
140-32-53 Size Group 3 In distribution
164-02-13 Extended Offset In distribution
180-10-44 Group 0 In distribution
160-23-15 EXT OFFSET In distribution
180-10-68 Group 5 In distribution
180-00-42 Group 00 In distribution
164-03-09 Standard Offset In distribution
180-01-64 Group 5 In distribution
180-10-50 Group 1 In distribution
164-01-14 Standard Offset In distribution
180-12-48 Group 1 In distribution
160-21-15 Extended Offset In distribution
167-02-00 In distribution
180-03-68 Group 5 In distribution
180-00-52 Group 2 In distribution
160-10-14 Standard Offset In distribution
160-32-13 STD OFFSET In distribution
164-03-11 Standard Offset In distribution
140-32-51 Size Group 1 In distribution
164-01-13 Standard Offset In distribution
160-10-09 Standard Offset In distribution
160-11-12 Extended Offset In distribution
160-21-09 Extended Offset In distribution
160-31-17 Extended Offset In distribution
167-00-00 In distribution
160-00-17 Standard Offset In distribution
160-11-10 Extended Offset In distribution
180-00-40 Group 00 In distribution
180-10-40 Group 00 In distribution
160-01-17 Extended Offset In distribution
160-01-11 Extended Offset In distribution
160-31-09 Extended Offset In distribution
160-30-12 Standard Offset In distribution
161-02-11 SIZE 11 In distribution
161-08-06 19/20 In distribution
164-13-12 Standard Offset In distribution
180-10-62 Group 4 In distribution
180-12-68 Group 5 In distribution
160-33-15 EXT OFFSET In distribution
180-00-50 Group 1 In distribution
160-20-11 Standard Offset In distribution
164-13-09 Standard Offset In distribution
180-13-68 Group 5 In distribution
164-02-08 Extended Offset In distribution
180-00-62 Group 4 In distribution
180-01-46 Group 0 In distribution
161-02-18 SIZE 18 In distribution
180-02-50 Group 1 In distribution
161-07-15 SIZE 17 In distribution
161-07-03 SIZE 15 In distribution
160-00-13 Standard Offset In distribution
160-30-18 Standard Offset In distribution
180-12-60 Group 4 In distribution
180-10-66 Group 5 In distribution
180-10-56 Group 3 In distribution
160-00-15 Standard Offset In distribution
160-11-18 Extended Offset In distribution
138-32-44 10 degree face changing In distribution
160-11-13 Extended Offset In distribution
160-30-15 Standard Offset In distribution
161-07-05 SIZE 17 In distribution
164-03-18 Standard Offset In distribution
160-23-17 EXT OFFSET In distribution
161-09-15 Reamer blade lead angle In distribution
180-01-60 Group 4 In distribution
161-08-09 Angle 3 ° In distribution
180-01-44 Group 0 In distribution
160-11-16 Extended Offset In distribution
164-13-10 Standard Offset In distribution
180-03-56 Group 3 In distribution
161-08-16 SIZE 16 In distribution
164-03-13 Standard Offset In distribution
160-31-11 Extended Offset In distribution
180-00-68 Group 5 In distribution
136-32-44 +5 Lateralized In distribution
136-22-70 +5 Lateralized In distribution
160-00-16 Standard Offset In distribution
180-01-58 Group 3 In distribution
164-13-08 Standard Offset In distribution
140-36-55 Size Group 5 In distribution
160-33-11 EXT OFFSET In distribution
160-10-12 Standard Offset In distribution
164-01-09 Standard Offset In distribution
160-01-16 Extended Offset In distribution
140-28-51 Size Group 1 In distribution
180-03-54 Group 2 In distribution
136-28-52 +5 Lateralized In distribution
160-21-10 Extended Offset In distribution
164-12-11 Extended Offset In distribution
160-30-17 Standard Offset In distribution
160-10-16 Standard Offset In distribution
160-11-11 Extended Offset In distribution
160-20-09 Standard Offset In distribution
180-13-52 Group 2 In distribution
180-01-54 Group 2 In distribution
167-00-02 In distribution
164-01-12 Standard Offset In distribution
164-12-08 Extended Offset In distribution
180-11-42 Group 00 In distribution
160-10-17 Standard Offset In distribution
160-01-12 Extended Offset In distribution
180-10-48 Group 1 In distribution
180-00-56 Group 3 In distribution
140-36-53 Size Group 3 In distribution
164-13-11 Standard Offset In distribution
180-03-64 Group 5 In distribution
180-12-54 Group 2 In distribution
164-03-10 Standard Offset In distribution
164-02-18 Extended Offset In distribution
180-01-62 Group 4 In distribution
180-13-64 Group 5 In distribution
160-30-11 Standard Offset In distribution
138-32-55 10 degree face changing In distribution
180-03-66 Group 5 In distribution
160-31-15 Extended Offset In distribution
136-28-50 +5 Lateralized In distribution
180-12-56 Group 3 In distribution
180-10-60 Group 4 In distribution
160-31-13 Extended Offset In distribution
160-31-12 Extended Offset In distribution
164-11-12 Standard Offset In distribution
180-12-58 Group 3 In distribution
164-01-08 Standard Offset In distribution
180-00-44 Group 0 In distribution
180-00-46 Group 0 In distribution
160-32-11 STD OFFSET In distribution
180-04-54 Group 3 In distribution
160-31-16 Extended Offset In distribution
164-12-10 Extended Offset In distribution
164-03-17 Standard Offset In distribution
161-01-03 In distribution
160-10-15 Standard Offset In distribution
160-11-14 Extended Offset In distribution
138-28-50 10 degree face changing In distribution
180-01-66 Group 5 In distribution
164-02-12 Extended Offset In distribution
167-01-00 In distribution
132-32-44 Lipped In distribution
SPI-051234 In distribution
180-01-56 Group 3 In distribution
160-20-13 Standard Offset In distribution
160-01-14 Extended Offset In distribution
164-02-09 Extended Offset In distribution
164-03-16 Standard Offset In distribution
167-00-04 In distribution
180-13-58 Group 3 In distribution
160-20-14 Standard Offset In distribution
180-01-52 Group 2 In distribution
160-11-17 Extended Offset In distribution
142-28-51 Lipped In distribution
161-08-11 Angle 3 ° In distribution
160-01-15 Extended Offset In distribution
160-20-12 Standard Offset In distribution
167-00-03 In distribution
164-12-12 Extended Offset In distribution
160-22-13 STD OFFSET In distribution
180-13-54 Group 2 In distribution
180-02-52 Group 2 In distribution
160-31-10 Extended Offset In distribution
180-01-50 Group 1 In distribution
138-36-43 10 degree face changing In distribution
160-22-15 STD OFFSET In distribution
160-10-18 Standard Offset In distribution
161-07-01 SIZE 13 In distribution
160-01-13 Extended Offset In distribution
164-11-09 Standard Offset In distribution
160-00-09 Standard Offset In distribution
160-20-10 Standard Offset In distribution
164-03-14 Standard Offset In distribution
180-03-60 Group 4 In distribution
160-32-17 STD OFFSET In distribution
164-02-10 Extended Offset In distribution
161-05-02 SIZE 2 In distribution
180-01-42 Group 00 In distribution
180-00-48 Group 1 In distribution
180-13-62 Group 4 In distribution
160-00-12 Standard Offset In distribution
164-01-10 Standard Offset In distribution
160-01-09 Extended Offset In distribution
160-30-09 Standard Offset In distribution
160-33-13 EXT OFFSET In distribution
138-36-45 10 degree face changing In distribution
167-01-00 In distribution
180-12-50 Group 1 In distribution
160-30-13 Standard Offset In distribution
164-01-16 Standard Offset In distribution
140-40-54 Size Group 4 In distribution
160-31-14 Extended Offset In distribution
164-02-17 Extended Offset In distribution
164-01-15 Standard Offset In distribution
160-33-17 EXT OFFSET In distribution
180-13-56 Group 3 In distribution
140-22-70 Size Group 00 In distribution
160-00-11 Standard Offset In distribution
180-10-52 Group 2 In distribution
180-12-66 Group 5 In distribution
164-03-15 Standard Offset In distribution
180-03-58 Group 3 In distribution
164-02-11 Extended Offset In distribution
164-11-08 Standard Offset In distribution
180-12-62 Group 4 In distribution
180-02-48 Group 1 In distribution
138-32-42 10 degree face changing In distribution
164-12-09 Extended Offset In distribution
160-31-18 Extended Offset In distribution
160-30-14 Standard Offset In distribution
160-10-13 Standard Offset In distribution
180-13-60 Group 4 In distribution
161-08-18 Reamer blade lead angle In distribution
160-10-10 Standard Offset In distribution
160-21-17 Extended Offset In distribution
164-02-16 Extended Offset In distribution
160-00-18 Standard Offset In distribution
160-30-16 Standard Offset In distribution
164-01-11 Standard Offset In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alteon Exactech, Inc. 326
Pinnacle Depuy Orthopaedics, Inc. 305
SP-CL Hip Stem Waldemar Link GmbH & Co. KG 219
Emperion Smith & Nephew, Inc. 201
MobileLink Acetabular Cup System Waldemar Link GmbH & Co. KG 154
Instrument Howmedica Osteonics Corp 145
Restoration Howmedica Osteonics Corp 144
Mfinity Femoral System Medacta International SA 138
Echelon Smith & Nephew, Inc. 134
Trinity Acetabular Hip System Corin Limited 128
Redapt Smith & Nephew, Inc. 127
Esop® Fournitures Hospitalieres Industrie 120

Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K243839 2025-03-10
K162732 2017-04-26
K153649 2016-08-31
K113320 2012-03-16
K080980 2008-05-06
K040613 2004-06-04
K000242 2000-02-16
K990197 1999-02-04

Recalls Naming This Product

30 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Novation
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Exactech, Inc. 510(k) number 2024-12-31 Class II Nonconforming Material/Component Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer. 42
Exactech, Inc. 510(k) number 2024-12-31 Class II Nonconforming Material/Component Due to the lack of the Ethylene Vinyl Alcohol (EVOH) barrier layer. 87
Exactech, Inc. 510(k) number 2023-11-21 Class II Packaging change control Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.
Exactech, Inc. 510(k) number 2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 58158 devices
Exactech, Inc. 510(k) number 2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 3793 devices
Exactech, Inc. 510(k) number 2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 17929 units
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2021-06-29 Class II Unknown/Undetermined by firm Risk of edge-loading and premature prosthesis wear is possible in a specific subset of patients with certain implant configurations and surgical implant positioning. 89,050 total
Exactech, Inc. 510(k) number 2016-11-07 Class II Under Investigation by firm Products were labeled with incorrect Global Trade Item Numbers. The GTIN on the label identifies the devices as another. 79 units 2019-08-05
Exactech, Inc. 510(k) number 2016-05-26 Class II Under Investigation by firm Labeled with the incorrect Global Trade Item Number (GTIN). The GTIN on the label identifies the devices as another. 8 units 2019-07-26
Exactech, Inc. 510(k) number 2016-05-26 Class II Under Investigation by firm Labeled with the incorrect Global Trade Item Number (GTIN). The GTIN on the label identifies the devices as another. 14 2019-07-26
Exactech, Inc. 510(k) number 2015-09-23 Class II Under Investigation by firm Eight (8) pieces did not receive the specified Hydroxyapatite (HA) coating. 8 2017-03-01
Exactech, Inc. 510(k) number 2012-11-05 Class II Labeling mix-ups Recall of Novation Crown Cup Connection GXL Neutral Liners Catalog No. (130-32-53) and Novation Crown Cup Connection GXL + 5mm Lateralized Liners Catalog No. (136-32-53). Exactech discovered the device labeling was inadvertently transposed 26 Units 2013-12-24
Exactech, Inc. 510(k) number 2012-11-05 Class II Labeling mix-ups Recall of Novation Crown Cup Connection GXL Neutral Liners Catalog No. (130-32-53) and Novation Crown Cup Connection GXL + 5mm Lateralized Liners Catalog No. (136-32-53). Exactech discovered the device labeling was inadvertently transposed 26 Units 2013-12-24

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-08-11 Class II Process control Specific GXL acetabular polyethylene liners, packaged in non-conforming bags, may adversely impact the device and contribute to accelerated wear. 136 devices
2017-10-09 Class II Error in labeling Wrong device description of the label identifying the implant 34 2019-08-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer