Restoration

Calcar Replacement Hip Stem

Registry build 21.09.26
14manufacturers in China registered for this device type
144catalogue numbers in this listing
19510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (8), Shanghai (2), Zhejiang (2). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code MEH
Manufacturer City Province Registered as Device types
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Xian Airfoil Technology Co., Ltd. Xian Shaanxi Contract manufacturer 8
Lincotek (Wuxi) Co., Ltd. Wuxi Jiangsu Contract manufacturer 7
b-ONE Medical (Beijing) Co., Ltd. Beijing Beijing Contract manufacturer 7
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Showing 12 of 14. All 14 manufacturers in China registered for Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

Record

Regulatory record for Restoration
Listed by Howmedica Osteonics Corp, United States
FDA product code MEH
Device type Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
Device class Class 2
Regulation 21 CFR 888.3353
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
510(k) K993077
Record published 2015-09-24
Record revised 2026-01-26 (version 10)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number
Sizes Length 15 to 60 mm; outer diameter 48 to 62 mm; lumen/inner diameter 22.2 mm

Catalogue Numbers

Catalogue numbers for Restoration
Catalogue number Size Status
6276-6-419 Distal Diameter: 19.0 Millimeter In distribution
2080-0040 Length 40.0 mm In distribution
6522-0814 Neck Length: 30.0 Millimeter In distribution
6522-0612 Stem Length: 145.0 Millimeter In distribution
6523-0511 Stem Length: 175.0 Millimeter In distribution
6524-1016R Taper Connection: C-TPR In distribution
6276-1-231 Diameter: 31.0 Millimeter In distribution
6276-6-012 Stem Length: 127.0 Millimeter In distribution
S-2651-0915 Stem Length: 155.0 Millimeter In distribution
S-2652-1420 Taper Connection: C-TPR In distribution
S-2652-1418 Neck Length: 40.0 Millimeter In distribution
2080-0035 Diameter: 6.5 Millimeter In distribution
6528-0915 Neck Length: 35.0 Millimeter In distribution
6276-8-625 Distal Diameter: 25.0 Millimeter In distribution
6524-0511L Neck Length: 25.0 Millimeter In distribution
6276-7-121 Stem Length: 195.0 Millimeter In distribution
6276-7-028 Stem Length: 155.0 Millimeter In distribution
6012-1014 Size: 10 In distribution
6529-0612 Size: 6 In distribution
6522-0511 Neck Length: 25.0 Millimeter In distribution
6012-0915 Taper Connection: C-TPR In distribution
6522-0711 Stem Length: 145.0 Millimeter In distribution
S-2652-0812 Neck Length: 30.0 Millimeter In distribution
6529-1117 Taper Connection: C-TPR In distribution
6528-0612 Stem Length: 175.0 Millimeter In distribution
6276-6-424 Stem Length: 217.0 Millimeter In distribution
6276-6-621 Stem Length: 317.0 Millimeter In distribution
2080-0060 Diameter: 6.5 Millimeter In distribution
6276-6-418 Distal Diameter: 18.0 Millimeter In distribution
6276-5-021 Stem Length: 127.0 Millimeter In distribution
6523-0610 Taper Connection: C-TPR In distribution
6528-1016 Stem Length: 175.0 Millimeter In distribution
6013-0913 Stem Length: 205.0 Millimeter In distribution
6523-1115 Size: 11 In distribution
6276-8-515 Stem Length: 267.0 Millimeter In distribution
6276-8-523 Distal Diameter: 23.0 Millimeter In distribution
6528-0511 Taper Connection: C-TPR In distribution
S-2652-0913 Taper Connection: C-TPR In distribution
6523-1014 Taper Connection: C-TPR In distribution
2080-0020 Length 20.0 mm In distribution
6276-7-328 Stem Length: 235.0 Millimeter In distribution
6276-5-217 Distal Diameter: 17.0 Millimeter In distribution
6523-0509 Taper Connection: C-TPR In distribution
S-2652-0915 Taper Connection: C-TPR In distribution
2080-0030 Length 30.0 mm In distribution
6012-0913 Taper Connection: C-TPR In distribution
6522-1014 Taper Connection: C-TPR In distribution
6012-1216 Neck Length: 45.0 Millimeter In distribution
6276-5-513 Distal Diameter: 13.0 Millimeter In distribution
6524-0612L Size: 6 In distribution
6276-7-420 Stem Length: 115.0 Millimeter In distribution
6529-1016 Size: 10 In distribution
6276-6-120 Stem Length: 167.0 Millimeter In distribution
6018-0814 Stem Length: 205.0 Millimeter In distribution
6276-1-331 Body Height: 30.0 Millimeter In distribution
S-2652-1422 Neck Length: 40.0 Millimeter In distribution
6529-0915 Size: 9 In distribution
6260-6-416 Size: 4 In distribution
6276-8-213 Distal Diameter: 13.0 Millimeter In distribution
S-2652-1216 Neck Length: 40.0 Millimeter In distribution
6012-1117 Size: 11 In distribution
6523-0915 Neck Length: 35.0 Millimeter In distribution
6276-4-123 Body Height: 10.0 Millimeter In distribution
6523-0812 Stem Length: 175.0 Millimeter In distribution
6522-0913 Taper Connection: C-TPR In distribution
6523-0612 Stem Length: 175.0 Millimeter In distribution
S-2651-1115 Stem Length: 155.0 Millimeter In distribution
6522-1117 Neck Length: 40.0 Millimeter In distribution
6524-0713R Neck Length: 30.0 Millimeter In distribution
6524-1016L Size: 10 In distribution
6529-0713 Stem Length: 175.0 Millimeter In distribution
6528-1117 Stem Length: 175.0 Millimeter In distribution
6524-0713L Stem Length: 205.0 Millimeter In distribution
6523-0711 Taper Connection: C-TPR In distribution
6276-6-211 Stem Length: 167.0 Millimeter In distribution
S-2652-0814 Stem Length: 205.0 Millimeter In distribution
6013-1218 Neck Length: 45.0 Millimeter In distribution
6276-7-223 Distal Diameter: 23.0 Millimeter In distribution
6524-0612R Neck Length: 25.0 Millimeter In distribution
6018-0915 Taper Connection: C-TPR In distribution
6524-0915R Neck Length: 35.0 Millimeter In distribution
6528-0814 Stem Length: 175.0 Millimeter In distribution
6523-0713 Stem Length: 175.0 Millimeter In distribution
6276-6-615 Stem Length: 317.0 Millimeter In distribution
6523-0913 Neck Length: 35.0 Millimeter In distribution
6523-0814 Taper Connection: C-TPR In distribution
S-2651-1117 Neck Length: 40.0 Millimeter In distribution
6276-1-121 Diameter: 21.0 Millimeter In distribution
2080-0045 Length 45.0 mm In distribution
6012-0713 Neck Length: 35.0 Millimeter In distribution
6013-1216 Size: 12 In distribution
6018-1218 Stem Length: 205.0 Millimeter In distribution
6276-7-317 Stem Length: 235.0 Millimeter In distribution
6012-1218 Size: 12 In distribution
6276-7-217 Distal Diameter: 17.0 Millimeter In distribution
6260-8-315 Distal Diameter: 15.0 Millimeter In distribution
6524-0814L Size: 8 In distribution
S-2652-1117 Size: 11 In distribution
6012-1016 Taper Connection: C-TPR In distribution
6522-0610 Stem Length: 145.0 Millimeter In distribution
6018-1117 Stem Length: 205.0 Millimeter In distribution
2080-0055 Diameter: 6.5 Millimeter In distribution
6013-1117 Taper Connection: C-TPR In distribution
6522-0509 Taper Connection: C-TPR In distribution
6276-6-018 Stem Length: 127.0 Millimeter In distribution
6276-8-525 Stem Length: 267.0 Millimeter In distribution
S-2651-0814 Stem Length: 155.0 Millimeter In distribution
2080-0050 Length 50.0 mm In distribution
6276-5-620 Stem Length: 317.0 Millimeter In distribution
6529-0814 Size: 8 In distribution
6523-1016 Neck Length: 35.0 Millimeter In distribution
6524-1117R Neck Length: 40.0 Millimeter In distribution
6522-0812 Stem Length: 145.0 Millimeter In distribution
6522-0713 Stem Length: 145.0 Millimeter In distribution
6276-7-118 Distal Diameter: 18.0 Millimeter In distribution
6260-6-517 Distal Diameter: 17.0 Millimeter In distribution
6524-0814R Taper Connection: C-TPR In distribution
6524-0511R Taper Connection: C-TPR In distribution
6018-1016 Taper Connection: C-TPR In distribution
2080-0025 Diameter: 6.5 Millimeter In distribution
6276-6-219 Stem Length: 167.0 Millimeter In distribution
6523-1117 Stem Length: 175.0 Millimeter In distribution
6528-0713 Neck Length: 30.0 Millimeter In distribution
6276-2-125 Diameter: 25.0 Millimeter In distribution
6522-0915 Neck Length: 35.0 Millimeter In distribution
6276-7-419 Distal Diameter: 19.0 Millimeter In distribution
6276-8-414 Distal Diameter: 14.0 Millimeter In distribution
6524-0915L Taper Connection: C-TPR In distribution
6276-8-216 Stem Length: 167.0 Millimeter In distribution
6276-1-129 Diameter: 29.0 Millimeter In distribution
6529-0511 Size: 5 In distribution
6018-1319 Size: 13 In distribution
S-2652-1014 Taper Connection: C-TPR In distribution
6276-1-027 Body Height: 0.0 Millimeter In distribution
6276-5-119 Distal Diameter: 19.0 Millimeter In distribution
6260-8-111 Stem Length: 203.0 Millimeter In distribution
6522-1115 Size: 11 In distribution
6276-6-113 Stem Length: 167.0 Millimeter In distribution
2080-0015 Length 15.0 mm In distribution
1235-2-254 Alpha Code: G In distribution
6524-1117L Size: 11 In distribution
1235-2-621 Side: RIGHT In distribution
6276-7-414 Distal Diameter: 14.0 Millimeter In distribution
6522-1016 Size: 10 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alteon Exactech, Inc. 326
Novation Exactech, Inc. 317
Pinnacle Depuy Orthopaedics, Inc. 305
SP-CL Hip Stem Waldemar Link GmbH & Co. KG 219
Emperion Smith & Nephew, Inc. 201
MobileLink Acetabular Cup System Waldemar Link GmbH & Co. KG 154
Instrument Howmedica Osteonics Corp 145
Mfinity Femoral System Medacta International SA 138
Echelon Smith & Nephew, Inc. 134
Trinity Acetabular Hip System Corin Limited 128
Redapt Smith & Nephew, Inc. 127
Esop® Fournitures Hospitalieres Industrie 120

Showing 12 of 805. All products under Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K122853 2013-02-01
K112556 2011-09-28
K093644 2009-12-18
K092406 2009-11-04
K092561 2009-10-20
K091161 2009-06-16
K082892 2008-12-29
K081044 2008-06-03
K072020 2007-10-18
K032300 2003-10-09
K023102 2002-10-09
K020615 2002-05-13
K020572 2002-03-04
K013676 2001-12-05
K001448 2000-08-04
K994366 2000-03-16
K993768 2000-01-21
K993077 1999-10-08
K992025 1999-08-13

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Restoration
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Howmedica Osteonics Corp 510(k) number 2002-12-02 Not classified Other Product mix-up. 16mm stem in a 18mm package. 6 2003-08-01

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-30 Not classified Process change control Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to 12,156 US
2014-12-15 Class II Process control Five customer complaints were received for the same batch of Trident PSL Shells (part number 540-11-50E lot 49073501) alleging that when the packages were opened there were no dome holes plugs present. seven units 2016-09-22
2014-02-03 Class II Error in labeling Stryker received a report from the field indicating that a citation TMZF HA 132 degrees neck angle V40 Hip Stem – Left Size # 4
was identified in a packaging associated with a citation TMZF HA 132 degrees Neck Angle V40 Hip Stem – Right S
48 units 2014-12-02
2012-10-23 Class II Labeling mix-ups Stryker has received a report that single size 3.5 stem was packaged as size 2.5 stem resulting in a possible product mix. 6021-2530- four units; 6021-3535- 2013-09-11
2012-04-30 Class II Device Design Stryker has updated the instruction for use (IFU) (product correction)for the ABGII Modular and Rejuvenate Modular Hip Systems. This is based on a reported rate of less than one percent for revisions potentially associated with fretting an 9003 units
2012-04-30 Class II Device Design Stryker has updated the instruction for use (IFU) (product correction)for the ABGII Modular and Rejuvenate Modular Hip Systems. This is based on a reported rate of less than one percent for revisions potentially associated with fretting an (NLS/NLV) – 23193 units and (SPT) – 20,743 units
2011-10-27 Not classified Error in labeling An incorrect laser mark was noted on specific lots of product, incorrectly implying a stem size of 9, when the product is actually size 8. 31 Units 2013-08-22
2011-09-06 Not classified Packaging As part of Stryker’s quality process, a packaging discrepancy was identified in specific lots of Stryker’s Duration packaging. 39,483 units 2015-11-17
2011-07-14 Not classified Mixed-up of materials/components Stryker Orthopaedics has become aware that a size 3 Accolade stem was in a box labeled as a size 5 Accolade stem. 21 units 2013-11-15
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-08-02 Not classified Device Design Stryker Orthopaedics determined that specific lots of the Omnifit Acetabular Shells may have a screw hole wall thickness that falls above the design specification. 2012-11-09
2010-01-21 Not classified Other The Restoration ADM Trial Cup Holder may not have been assembled correctly. 5 units 2012-06-20
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-06-26 Not classified Nonconforming Material/Component Raw material supplied by a third party used to manufacture various medical devices does not comply with metallurgical requirements outlines in ASTM standard for titanium surgical implants. 51,113 total – all sizes. 2010-07-27
2009-01-14 Not classified Device Design Stryker Orthopaedics became aware that there may be difficulty in mating stem to implantation/extraction instrument. 786 total stems 2012-07-18
2009-01-14 Not classified Device Design Stryker Orthopaedics became aware that there may be difficulty in mating stem to implantation/extraction instrument. 786 total stems 2012-07-18
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25
2009-01-06 Not classified Process control Product deviation : Specific lots of sprayed HA hip stems did not meet Stryker’s Internal Material Specification for tensile bond strength and crystallinity. 1,628 total stems, all varieties. 2012-06-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer