Firebird Sfs;sfs;sfs LE
25MM Fixed Cross Connector
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Shandong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Shanghai Reach Medical Instrument Co., Ltd. | Shanghai | Shanghai | Manufacturer | 30 |
| Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 25 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
Showing 12 of 15. All 15 manufacturers in China registered for Thoracolumbosacral Pedicle Screw System
Record
| Listed by | Orthofix US LLC, United States |
|---|---|
| FDA product code | NKB |
| Device type | Thoracolumbosacral Pedicle Screw System |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3070 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K180179 |
| Record published | 2019-03-12 |
| Record revised | 2026-02-20 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 57-5325 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| The Jasper Spinal Fixation System | Gbs Commonwealth Co., Ltd. | 32,491 |
| Invictus | Alphatec Spine, Inc. | 4,722 |
| Vital Spinal Fixation System | Highridge Medical, LLC | 4,422 |
| Innoverse Spinal System | CG MedTech Co., Ltd. | 4,240 |
| 4CIS® Chiron Spinal Fixation System | Alpha AI Co., Ltd. | 3,787 |
| LnK Spinal Fixation System | L&K Biomed Co., Ltd. | 3,522 |
| Hedjet System | Medyssey Co., Ltd. | 3,438 |
| Anax™ 5.5 Spinal System | CG MedTech Co., Ltd. | 3,424 |
| Mega Plus MIS Spine System | BK Meditech Co., Ltd. | 3,396 |
| ReLine | Nuvasive, Inc. | 2,882 |
| Nex-D2 | Next Orthosurgical | 2,765 |
| AnyPlus Spinal Fixation System | GS Medical Co., Ltd. | 2,386 |
Showing 12 of 1,490. All products under Thoracolumbosacral Pedicle Screw System
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-09-19 | Class II | Process change control | Polyaxial screws do not meet performance standards. | 624 units | |
| 2017-08-02 | Class II | Nonconforming Material/Component | The plastic core of the Decorticating Planer was found to be missing, which could result in scoring of the bone screw neck if used at or beyond a 23 degree angle. | 6 planers | 2018-05-04 |
| 2015-05-18 | Class II | Unknown/Undetermined by firm | The Firebird Spinal Fixation System 6.5 mm x 55 mm Bone Screw, Self-Tapping is currently mislabeled at the distal tip of the bone screw showing a length measurement of 50 mm instead of 55 mm. | 45 units | 2015-10-30 |
| 2011-04-01 | Not classified | Device Design | Upon reaching torque limit, there is a possibility the product may jam or exhibit a ratchet direction switch from forward to reverse. | 287 units | 2012-03-23 |
| 2010-10-22 | Not classified | Other | There is a possibility that certain Anti-Splay Caps may not mate properly during assembly of the construct to the Screw Body with Multi-Axial Reduction Screw Assemblies. | 166 Units | 2011-04-25 |
| 2010-10-22 | Not classified | Other | There is a possibility that certain Multi-Axial Screws have spherical heads measuring less than the allowable tolerance. | 27 (19 of 77-7630) (8 of 77-8630) | 2011-05-31 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.