Mariner Deformity

Mariner Deformity is a spinal fixation range that extends the Mariner pedicle screw platform for adult deformity applications. It combines implants with instruments for placement,…

Registry build 21.09.26

Mariner Deformity is a spinal fixation range that extends the Mariner pedicle screw platform for adult deformity applications. It combines implants with instruments for placement, adjustment, correction and final locking of the fixation construct.

The implant options include pre-contoured or constrained rods, uni-planar and fenestrated screws, hooks, lateral connectors and modular screw heads. Across the platform, implant materials include titanium alloy and cobalt-chromium alloys.

Listed Item

Mariner Deformity Extended Tab Uni-Planar Screw Caddy

Instruments and Storage

Placement and correction instruments serve different roles from the single-use implants. The range also includes trays and screw caddies that organize and protect components before and during steam sterilization; a caddy is part of this support equipment.

15manufacturers in China registered for this device type
171catalogue numbers in this listing
14510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Shandong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NKB
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Shanghai Reach Medical Instrument Co., Ltd. Shanghai Shanghai Manufacturer 30
Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. Changzhou Jiangsu Contract manufacturer 25
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14

Showing 12 of 15. All 15 manufacturers in China registered for Thoracolumbosacral Pedicle Screw System

Record

Regulatory record for Mariner Deformity
Listed by Seaspine Orthopedics Corporation, United States
FDA product code NKB
Device type Thoracolumbosacral Pedicle Screw System
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K211606
Record published 2021-08-25
Record revised 2025-10-24 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Mariner Deformity
Catalogue number Size Status
MD1-586063 In distribution
MD1-218570 In distribution
MD1-300011-12 In distribution
MD1-238560 In distribution
MD1-565542 In distribution
MD1-556041 In distribution
MF3-100003 In distribution
MD1-116535 In distribution
MF3-100007 In distribution
MD2-002002 In distribution
MD3-205011 In distribution
MF1-265055 In distribution
MD1-116545 In distribution
MD1-125555 In distribution
MD3-005008 In distribution
MD1-115530 In distribution
MF1-285055 In distribution
MD1-625600 In distribution
MD1-248560 In distribution
MD1-576043 In distribution
MD1-100002 In distribution
MD1-545543 In distribution
MD1-576041 In distribution
MD1-136555 In distribution
MD1-566043 In distribution
MF1-245050 In distribution
MD2-002004 In distribution
MD1-545541 In distribution
MD3-006008 In distribution
MD1-125545 In distribution
MD1-127540 In distribution
MF3-100006 In distribution
MD3-203004 In distribution
MD1-226560 In distribution
MD1-115535 In distribution
MD3-201005 In distribution
MD1-137550 In distribution
MD1-545563 In distribution
MD1-135545 In distribution
MF1-155055 In distribution
MD2-101014 In distribution
MD1-137555 In distribution
MD3-004002 In distribution
MD1-115525 In distribution
MD2-213085 In distribution
MF1-185045 In distribution
MD1-585541 In distribution
MD1-656450 In distribution
MD1-566061 In distribution
MD3-205009 In distribution
MF1-155040 In distribution
MD1-256560 In distribution
MD3-006025 In distribution
MD1-526061 In distribution
MD3-002002 In distribution
MD1-525563 In distribution
MD3-203001 In distribution
MD1-345530 In distribution
MD3-203002 In distribution
MD2-002010 In distribution
MF1-255060 In distribution
MD1-236570 In distribution
MF1-185060 In distribution
MD3-001002 In distribution
MF1-255040 In distribution
MD1-576061 In distribution
MD1-636450 In distribution
MD3-205005 In distribution
MD1-536061 In distribution
MD1-556062 In distribution
MF3-100009 In distribution
MD2-102001 In distribution
MD3-005006 In distribution
MD3-006003 In distribution
MD1-645600 In distribution
MD1-616600 In distribution
MD1-127535 In distribution
MD1-625250 In distribution
MF1-155035 In distribution
MD1-635600 In distribution
MD1-228560 In distribution
MD1-228580 In distribution
MD1-516041 In distribution
MD1-546053 In distribution
MF3-100001 In distribution
MD3-002004 In distribution
MD1-116540 In distribution
MF1-145045 In distribution
MD1-325545 In distribution
MD1-136545 In distribution
MF1-255055 In distribution
MD2-213070 In distribution
MF1-265035 In distribution
MD1-545562 In distribution
MD1-226570 In distribution
MD1-565563 In distribution
MD3-006004 In distribution
99-9017 In distribution
MD1-575543 In distribution
MD1-555562 In distribution
MF1-165040 In distribution
MF1-185040 In distribution
MD1-116530 In distribution
MD1-126540 In distribution
MD1-246570 In distribution
MF1-155045 In distribution
MD1-525561 In distribution
MD1-227570 In distribution
MD1-536062 In distribution
MD3-210001 In distribution
MD1-127545 In distribution
MD3-005010 In distribution
MD1-266580 In distribution
MD3-006026 In distribution
MD1-545542 In distribution
MD1-114540 In distribution
MD1-137535 In distribution
MD1-626600 In distribution
MD1-526051 In distribution
MD1-565543 In distribution
MF1-265060 In distribution
MF1-285035 In distribution
MD3-202002 In distribution
MD1-576042 In distribution
MD2-213120 In distribution
MD1-546042 In distribution
MD2-102010 In distribution
MD1-565561 In distribution
MD3-205022 In distribution
MD1-237570 In distribution
MF1-275050 In distribution
MD1-134545 In distribution
MD2-213095 In distribution
MD1-125535 In distribution
MD3-204001 In distribution
MD1-645450 In distribution
MD1-515551 In distribution
MD2-003013 In distribution
MD3-005009 In distribution
MD3-205013 In distribution
MD1-516061 In distribution
MD3-006011 In distribution
MD1-237560 In distribution
MD2-003024 In distribution
MD3-006015 In distribution
MD1-100026 In distribution
MD1-248570 In distribution
MD3-202003 In distribution
MD1-136550 In distribution
MD1-526063 In distribution
MD2-102015 In distribution
MD1-625450 In distribution
MD1-516063 In distribution
MF1-285045 In distribution
MD3-205010 In distribution
MD1-585542 In distribution
MD1-125540 In distribution
MD1-257560 In distribution
MD1-576063 In distribution
MD1-575541 In distribution
MD1-525542 In distribution
MD1-515562 In distribution
MD1-135540 In distribution
MD3-005005 In distribution
MD1-656600 In distribution
MD3-006028 In distribution
MD3-205008 In distribution
MD3-006006 In distribution
MD3-204004 In distribution
MD1-345545 In distribution
MF1-275060 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
The Jasper Spinal Fixation System Gbs Commonwealth Co., Ltd. 32,491
Invictus Alphatec Spine, Inc. 4,722
Vital Spinal Fixation System Highridge Medical, LLC 4,422
Innoverse Spinal System CG MedTech Co., Ltd. 4,240
4CIS® Chiron Spinal Fixation System Alpha AI Co., Ltd. 3,787
LnK Spinal Fixation System L&K Biomed Co., Ltd. 3,522
Hedjet System Medyssey Co., Ltd. 3,438
Anax™ 5.5 Spinal System CG MedTech Co., Ltd. 3,424
Mega Plus MIS Spine System BK Meditech Co., Ltd. 3,396
ReLine Nuvasive, Inc. 2,882
Nex-D2 Next Orthosurgical 2,765
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 2,386

Showing 12 of 1,490. All products under Thoracolumbosacral Pedicle Screw System

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250908 2025-06-18
K232566 2024-04-19
K222110 2022-09-07
K212692 2021-09-21
K211606 2021-06-23
K200381 2020-02-28
K191648 2019-07-19
K183639 2019-05-23
K180686 2018-05-14
K180176 2018-02-20
K173882 2018-02-06
K163604 2017-03-09
K161535 2016-09-08
K160902 2016-05-26

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Mariner Deformity
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Seaspine Orthopedics Corporation 510(k) number 2026-05-28 Class II Process change control Due to manufacturing error, polyaxial head may popoff from the screw intraoperatively following insertion. 796 units
Seaspine Orthopedics Corporation 510(k) number 2024-02-28 Class II Nonconforming Material/Component Screw heads, of pedicle screw systems, have partial thread within the screw head that pose a risk of intraoperative cross-threading within the locking cap/screw head interface. 444 Screw Heads
Seaspine Orthopedics Corporation 510(k) number 2024-02-15 Class II Nonconforming Material/Component Screw heads, of pedicle screw systems, have thin lead-in thread that pose a risk of intraoperative cross-threading within the locking cap/screw head interface. 1579 Screw Heads

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-10-29 Class II Nonconforming Material/Component Due to manufacturing defects observed on Locking Caps that affect the ability for components to mate. 191 devices
2024-10-29 Class II Nonconforming Material/Component Due to manufacturing defects observed on Locking Caps that affect the ability for components to mate. 92 devices

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer