#REF!

4.75 x 115 mm CoCr-Standard Curved Rod

Registry build 21.09.26
15manufacturers in China registered for this device type
53catalogue numbers in this listing
1510(k) clearance
4recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Shandong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NKB
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Shanghai Reach Medical Instrument Co., Ltd. Shanghai Shanghai Manufacturer 30
Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. Changzhou Jiangsu Contract manufacturer 25
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14

Showing 12 of 15. All 15 manufacturers in China registered for Thoracolumbosacral Pedicle Screw System

Record

Regulatory record for #REF!
Listed by Highridge Medical, LLC, United States
FDA product code NKB
Device type Thoracolumbosacral Pedicle Screw System
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Specification developer, Manufacturer
Record published 2025-11-21

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization

Catalogue Numbers

Catalogue numbers for #REF!
Catalogue number Size Status
14-587611CH Device Size Text, specify—4.75 X 110 MM COCR-HIGH CURVED ROD In distribution
14-587912CL Device Size Text, specify—4.75 X 125 MM COCR-LOW CURVED ROD In distribution
14-587604CS Device Size Text, specify—4.75 X 40 MM COCR-STANDARD CURVED ROD In distribution
14-587904CL Device Size Text, specify—4.75 X 45 MM COCR-LOW CURVED ROD In distribution
14-587606CL Device Size Text, specify—4.75 X 60 MM COCR-LOW CURVED ROD In distribution
14-587911CS Device Size Text, specify—4.75 X 115 MM COCR-STANDARD CURVED ROD In distribution
14-587606CH Device Size Text, specify—4.75 X 60 MM COCR-HIGH CURVED ROD In distribution
14-587903CS Device Size Text, specify—4.75 X 35 MM COCR-STANDARD CURVED ROD In distribution
14-587904CS Device Size Text, specify—4.75 X 45 MM COCR-STANDARD CURVED ROD In distribution
14-587603CH Device Size Text, specify—4.75 X 30 MM COCR-HIGH CURVED ROD In distribution
14-587603CS Device Size Text, specify—4.75 X 30 MM COCR-STANDARD CURVED ROD In distribution
14-587611CL Device Size Text, specify—4.75 X 110 MM COCR-LOW CURVED ROD In distribution
14-587904T Device Size Text, specify—4.75 x 45 mm Ti Alloy Curved Rod In distribution
14-587912CS Device Size Text, specify—4.75 X 125 MM COCR-STANDARD CURVED ROD In distribution
14-587613T Device Size Text, specify—4.75 x 130 mm Ti Alloy Curved Rod In distribution
14-587910CH Device Size Text, specify—4.75 X 105 MM COCR-HIGH CURVED ROD In distribution
14-587612CS Device Size Text, specify—4.75 X 120 MM COCR-STANDARD CURVED ROD In distribution
14-587613CH Device Size Text, specify—4.75 X 130 MM COCR-HIGH CURVED ROD In distribution
14-587613CL Device Size Text, specify—4.75 X 130 MM COCR-LOW CURVED ROD In distribution
14-587605CL Device Size Text, specify—4.75 X 50 MM COCR-LOW CURVED ROD In distribution
14-587905CS Device Size Text, specify—4.75 X 55 MM COCR-STANDARD CURVED ROD In distribution
14-587912T Device Size Text, specify—4.75 x 125 mm Ti Alloy Curved Rod In distribution
14-587605T Device Size Text, specify—4.75 x 50 mm Ti Alloy Curved Rod In distribution
14-587611CS Device Size Text, specify—4.75 X 110 MM COCR-STANDARD CURVED ROD In distribution
14-587903CH Device Size Text, specify—4.75 X 35 MM COCR-HIGH CURVED ROD In distribution
14-587612CH Device Size Text, specify—4.75 X 120 MM COCR-HIGH CURVED ROD In distribution
14-587911T Device Size Text, specify—4.75 x 115 mm Ti Alloy Curved Rod In distribution
14-587911CL Device Size Text, specify—4.75 X 115 MM COCR-LOW CURVED ROD In distribution
14-587610T Device Size Text, specify—4.75 x 100 mm Ti Alloy Curved Rod In distribution
14-587905CH Device Size Text, specify—4.75 X 55 MM COCR-HIGH CURVED ROD In distribution
14-587904CH Device Size Text, specify—4.75 X 45 MM COCR-HIGH CURVED ROD In distribution
14-587612CL Device Size Text, specify—4.75 X 120 MM COCR-LOW CURVED ROD In distribution
14-587605CH Device Size Text, specify—4.75 X 50 MM COCR-HIGH CURVED ROD In distribution
14-587603CL Device Size Text, specify—4.75 X 30 MM COCR-LOW CURVED ROD In distribution
14-587911CH Device Size Text, specify—4.75 X 115 MM COCR-HIGH CURVED ROD In distribution
14-587603T Device Size Text, specify—4.75 x 30 mm Ti Alloy Curved Rod In distribution
14-587611T Device Size Text, specify—4.75 x 110 mm Ti Alloy Curved Rod In distribution
14-587604CH Device Size Text, specify—4.75 X 40 MM COCR-HIGH CURVED ROD In distribution
14-587912CH Device Size Text, specify—4.75 X 125 MM COCR-HIGH CURVED ROD In distribution
14-587910CS Device Size Text, specify—4.75 X 105 MM COCR-STANDARD CURVED ROD In distribution
14-587905T Device Size Text, specify—4.75 x 55 mm Ti Alloy Curved Rod In distribution
14-587610CL Device Size Text, specify—4.75 X 100 MM COCR-LOW CURVED ROD In distribution
14-587605CS Device Size Text, specify—4.75 X 50 MM COCR-STANDARD CURVED ROD In distribution
14-587604CL Device Size Text, specify—4.75 X 40 MM COCR-LOW CURVED ROD In distribution
14-587910T Device Size Text, specify—4.75 x 105 mm Ti Alloy Curved Rod In distribution
14-587903CL Device Size Text, specify—4.75 X 35 MM COCR-LOW CURVED ROD In distribution
14-587610CH Device Size Text, specify—4.75 X 100 MM COCR-HIGH CURVED ROD In distribution
14-587612T Device Size Text, specify—4.75 x 120 mm Ti Alloy Curved Rod In distribution
14-587610CS Device Size Text, specify—4.75 X 100 MM COCR-STANDARD CURVED ROD In distribution
14-587903T Device Size Text, specify—4.75 x 35 mm Ti Alloy Curved Rod In distribution
14-587604T Device Size Text, specify—4.75 x 40 mm Ti Alloy Curved Rod In distribution
14-587905CL Device Size Text, specify—4.75 X 55 MM COCR-LOW CURVED ROD In distribution
14-587613CS Device Size Text, specify—4.75 X 130 MM COCR-STANDARD CURVED ROD In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
The Jasper Spinal Fixation System Gbs Commonwealth Co., Ltd. 32,491
Invictus Alphatec Spine, Inc. 4,722
Vital Spinal Fixation System Highridge Medical, LLC 4,422
Innoverse Spinal System CG MedTech Co., Ltd. 4,240
4CIS® Chiron Spinal Fixation System Alpha AI Co., Ltd. 3,787
LnK Spinal Fixation System L&K Biomed Co., Ltd. 3,522
Hedjet System Medyssey Co., Ltd. 3,438
Anax™ 5.5 Spinal System CG MedTech Co., Ltd. 3,424
Mega Plus MIS Spine System BK Meditech Co., Ltd. 3,396
ReLine Nuvasive, Inc. 2,882
Nex-D2 Next Orthosurgical 2,765
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 2,386

Showing 12 of 1,490. All products under Thoracolumbosacral Pedicle Screw System

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253093 2025-12-17

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-10-16 Class II Nonconforming Material/Component Spinal fixation system 7.5mmx 50mm screws are packaged with the correct labeling, but the screws themselves were laser marked with an incorrect size description of 7.5 x 40; use of incorrect screws could lead to screw perforation and indent 3
2018-07-30 Class II Nonconforming Material/Component The Vitality Shear-off Set Screw is not threading properly with the mating tulip head of the Vitality screws, hooks and connectors due to a manufacturing issue.These devices are indicated as an adjunct to fusion for various indications 16,429 devices (Thoracolumbosacral pedicle screw system,Spin 2021-04-28
2012-11-30 Class II Process control Biomet Spine LLC is recalling the Set Screw 5.5 mm Rod due to the set screw being out of specification 1999 2015-05-22
2011-12-19 Class II Device Design The Telluride Percutaneous Rod Inserter Long does not contain a feature that locks the Rod in place during use. There is a potential for the Rod to disengage from the Inserter during insertion, and could lead to harm to the patient. 10 2015-03-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer