Response 5.5/6.0 Cannulated Screw System

RESPONSE 5.5/6.0 Cannulated Screw System adds guidewire-compatible pedicle screws to the RESPONSE spinal fixation construct. The screws anchor to bone and connect with the previously…

Registry build 21.09.26

RESPONSE 5.5/6.0 Cannulated Screw System adds guidewire-compatible pedicle screws to the RESPONSE spinal fixation construct. The screws anchor to bone and connect with the previously established rods and connectors to stabilize the posterior, non-cervical spine.

The hollow screws pass over a guidewire during insertion. Cannulated drivers engage their hexalobe interface, and the screw range covers diameters from 6 to 9 mm with lengths varying by diameter.

Listed Item

5.5/6.0 Cannulated Polyaxial Reduction Screw, 6.5mm x 50mm

Construct and Supply

System implant materials include titanium alloy, cobalt-chromium alloy and commercially pure titanium. Components are supplied nonsterile. The screws are used with the RESPONSE 5.5/6.0 Spine System as an adjunct to fusion in adults and for specified pediatric scoliosis procedures; pediatric fixation is posterior only.

15manufacturers in China registered for this device type
55catalogue numbers in this listing
5510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Shandong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NKB
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Shanghai Reach Medical Instrument Co., Ltd. Shanghai Shanghai Manufacturer 30
Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. Changzhou Jiangsu Contract manufacturer 25
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14

Showing 12 of 15. All 15 manufacturers in China registered for Thoracolumbosacral Pedicle Screw System

Record

Regulatory record for Response 5.5/6.0 Cannulated Screw System
Listed by Orthopediatrics, Corp, United States
FDA product code NKB
Device type Thoracolumbosacral Pedicle Screw System
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K222105
Record published 2023-03-31
Record revised 2024-09-11 (version 4)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Response 5.5/6.0 Cannulated Screw System
Catalogue number Size Status
00-1301-2780 In distribution
00-1301-2750 In distribution
00-1301-3670 In distribution
00-1301-3710 In distribution
00-1301-3660 In distribution
00-1301-3960 In distribution
00-1301-2990 In distribution
00-1301-7665 In distribution
00-1301-3740 In distribution
00-1301-3975 In distribution
00-1301-2875 In distribution
00-1301-2910 In distribution
00-1301-2980 In distribution
00-1301-2845 In distribution
00-1301-3990 In distribution
00-1301-2840 In distribution
00-1301-3770 In distribution
00-1301-3850 In distribution
00-1301-2860 In distribution
00-1301-2660 In distribution
00-1301-2640 In distribution
00-1301-2755 In distribution
00-1301-3950 In distribution
00-1301-2675 In distribution
00-1301-3755 In distribution
00-1301-2950 In distribution
00-1301-2680 In distribution
00-1301-3980 In distribution
00-1301-3880 In distribution
00-1301-9650 In distribution
00-1301-3940 In distribution
00-1301-7690 In distribution
00-1301-7650 In distribution
00-1301-9655 In distribution
00-1301-3945 In distribution
00-1301-2865 In distribution
00-1301-2645 In distribution
00-1301-9670 In distribution
00-1301-3855 In distribution
00-1301-2960 In distribution
00-1301-2855 In distribution
00-1301-2650 In distribution
00-1301-7645 In distribution
00-1301-2880 In distribution
00-1301-7675 In distribution
00-1301-3665 In distribution
00-1301-7680 In distribution
00-1301-3870 In distribution
00-1301-2790 In distribution
00-1301-2765 In distribution
00-1301-3640 In distribution
00-1301-3775 In distribution
00-1301-2710 In distribution
00-1301-3680 In distribution
00-1301-3765 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
The Jasper Spinal Fixation System Gbs Commonwealth Co., Ltd. 32,491
Invictus Alphatec Spine, Inc. 4,722
Vital Spinal Fixation System Highridge Medical, LLC 4,422
Innoverse Spinal System CG MedTech Co., Ltd. 4,240
4CIS® Chiron Spinal Fixation System Alpha AI Co., Ltd. 3,787
LnK Spinal Fixation System L&K Biomed Co., Ltd. 3,522
Hedjet System Medyssey Co., Ltd. 3,438
Anax™ 5.5 Spinal System CG MedTech Co., Ltd. 3,424
Mega Plus MIS Spine System BK Meditech Co., Ltd. 3,396
ReLine Nuvasive, Inc. 2,882
Nex-D2 Next Orthosurgical 2,765
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 2,386

Showing 12 of 1,490. All products under Thoracolumbosacral Pedicle Screw System

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K222105 2023-03-23
K193100 2020-03-24
K181390 2018-09-18
K160466 2016-03-23
K150600 2015-05-22

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-07-06 Class II Under Investigation by firm Product may have incorrect laser etched alignment lines, the non-conforming laser etch may have compromised strength, lead to unintended fracture of the device 73 units
2015-11-10 Class II Process change control Response Spine UniAxial Pedicle & UniAxial Reduction Pedicle Screws may have been manufactured incorrectly, thus preventing the driver from fully engaging into the hexagonal drive feature of the screw. 102 2016-05-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer