Streamline TL Spinal Fixation System

STREAMLINE TL, Ø7.5MM DL CANNULATED PEDICLE REDUCTION SCREW ASSEMBLY, 100mm

Registry build 21.09.26
15manufacturers in China registered for this device type
138catalogue numbers in this listing
1510(k) clearance
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (3), Shandong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code NKB
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zibo Dante Co., Ltd. Zibo Shandong Contract manufacturer 17
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Shanghai Reach Medical Instrument Co., Ltd. Shanghai Shanghai Manufacturer 30
Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. Changzhou Jiangsu Contract manufacturer 25
Double Medical Technology Inc. Xiamen Fujian Contract manufacturer 14

Showing 12 of 15. All 15 manufacturers in China registered for Thoracolumbosacral Pedicle Screw System

Record

Regulatory record for Streamline TL Spinal Fixation System
Listed by Xtant Medical Holdings, Inc., United States
FDA product code NKB
Device type Thoracolumbosacral Pedicle Screw System
Device class Class 2
Regulation 21 CFR 888.3070
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K192800
Record published 2026-04-21
Record revised 2025-11-20 (version 11)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Distribution end date 2025-05-09

Catalogue Numbers

Catalogue numbers for Streamline TL Spinal Fixation System
Catalogue number Size Status
01-PA-C-45-40 In distribution
01-RS-C-75-35 In distribution
01-PA-C-65-40 In distribution
01-PA-65-20 In distribution
01-RS-C-85-35 In distribution
01-PA-C-45-45 In distribution
01-PA-65-100 In distribution
01-PA-55-25 In distribution
01-RS-C-75-70 In distribution
01-RS-C-55-30 In distribution
01-PA-C-85-45 In distribution
01-PA-105-55 In distribution
01-RS-65-60 In distribution
01-PA-C-65-60 In distribution
01-PA-C-75-80 In distribution
01-PA-65-95 In distribution
01-PA-75-55 In distribution
01-PA-C-85-70 In distribution
01-PA-105-90 In distribution
01-FXL-25 In distribution
01-PA-C-55-35 In distribution
01-PA-65-70 In distribution
01-RS-C-75-75 In distribution
01-PA-C-45-30 In distribution
10-55-PR-RL-100 5.5mm(D)x 100mm(L) In distribution
01-PA-65-30 In distribution
01-FX-75-100 In distribution
01-PA-95-35 In distribution
01-LOCO-15 In distribution
01-PA-95-40 In distribution
01-PA-C-85-30 In distribution
01-RS-C-75-60 In distribution
10-55-PR-RL-70 5.5mm(D)x 70mm(L) In distribution
01-PA-C-45-25 In distribution
01-PA-C-85-60 In distribution
01-PA-75-95 In distribution
10-55-PR-RL-140 5.5mm(D)x 140mm(L) In distribution
01-FX-65-85 In distribution
01-FX-75-30 In distribution
01-PA-115-45 In distribution
01-PA-55-55 In distribution
01-FXL-34 In distribution
01-RS-55-60 In distribution
10-55-PR-RL-110 5.5mm(D)x 110mm(L) In distribution
01-RS-C-85-60 In distribution
01-PA-55-50 In distribution
01-PA-85-75 In distribution
01-PA-95-80 In distribution
01-RS-C-55-40 In distribution
10-55-PR-RL-95 5.5mm(D)x 95mm(L) In distribution
01-RS-C-45-30 In distribution
10-55-PR-RL-45 5.5mm(D)x 45mm(L) In distribution
10-55-RHC-600 In distribution
01-PA-65-60 In distribution
01-PA-C-45-20 In distribution
01-FX-65-70 In distribution
01-PA-55-35 In distribution
01-PA-70-45 In distribution
01-RS-75-95 In distribution
01-PA-C-55-45 In distribution
01-RS-C-75-100 In distribution
01-PA-55-45 In distribution
01-PA-85-85 In distribution
01-PA-65-80 In distribution
10-55-PR-RL-60 5.5mm(D)x 60mm(L) In distribution
01-PA-C-75-60 In distribution
01-RS-C-55-55 In distribution
01-PA-75-90 In distribution
01-PA-C-65-90 In distribution
01-PA-75-65 In distribution
01-PA-C-55-55 In distribution
01-PA-105-45 In distribution
01-PA-C-65-65 In distribution
01-PA-C-55-30 In distribution
01-PA-115-50 In distribution
01-PA-75-40 In distribution
10-55-PR-RL-90 5.5mm(D)x 90mm(L) In distribution
10-55-PR-110 In distribution
01-FX-65-40 In distribution
10-55-RR-60 In distribution
01-PA-85-80 In distribution
01-RS-C-75-30 In distribution
01-PA-65-45 In distribution
01-RS-C-45-20 In distribution
01-LOCO-20 In distribution
01-RS-75-30 In distribution
01-PA-C-85-40 In distribution
01-VXL-SM In distribution
10-55-RR-50 In distribution
01-RS-55-40 In distribution
01-RS-C-85-40 In distribution
01-RS-C-85-55 In distribution
10-55-PR-125 In distribution
01-PA-C-85-55 In distribution
01-PA-105-40 In distribution
01-PA-C-65-95 In distribution
01-FXL-22 In distribution
01-PA-55-20 In distribution
01-PA-85-35 In distribution
01-PA-C-55-50 In distribution
01-FX-55-40 In distribution
01-RS-75-35 In distribution
01-FXL-31 In distribution
01-RS-C-75-40 In distribution
01-PA-85-20 In distribution
01-FX-65-65 In distribution
01-FX-55-35 In distribution
10-55-RH-600 In distribution
01-PA-45-30 In distribution
01-PA-C-65-30 In distribution
01-PA-C-85-35 In distribution
01-FX-45-35 In distribution
01-PA-75-100 In distribution
01-PA-C-75-45 In distribution
01-PA-45-35 In distribution
01-PA-C-65-35 In distribution
01-PA-C-75-40 In distribution
01-RS-C-75-45 In distribution
01-FX-55-30 In distribution
01-PA-C-45-35 In distribution
01-PA-C-65-75 In distribution
01-PA-95-45 In distribution
01-FX-75-60 In distribution
01-RS-C-65-60 In distribution
10-55-PR-RL-105 5.5mm(D)x 105mm(L) In distribution
01-PA-75-30 In distribution
01-PA-65-35 In distribution
01-PA-95-100 In distribution
01-FXL-28 In distribution
01-PA-115-70 In distribution
10-55-PR-150 In distribution
10-55-PR-70 In distribution
01-PA-C-75-30 In distribution
10-55-PR-RL-50 5.5mm(D)x 50mm(L) In distribution
01-VXL-SM Withdrawn
01-RS-C-95-90 Withdrawn
01-SETSCREW Withdrawn
01-RS-C-95-80 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
The Jasper Spinal Fixation System Gbs Commonwealth Co., Ltd. 32,491
Invictus Alphatec Spine, Inc. 4,722
Vital Spinal Fixation System Highridge Medical, LLC 4,422
Innoverse Spinal System CG MedTech Co., Ltd. 4,240
4CIS® Chiron Spinal Fixation System Alpha AI Co., Ltd. 3,787
LnK Spinal Fixation System L&K Biomed Co., Ltd. 3,522
Hedjet System Medyssey Co., Ltd. 3,438
Anax™ 5.5 Spinal System CG MedTech Co., Ltd. 3,424
Mega Plus MIS Spine System BK Meditech Co., Ltd. 3,396
ReLine Nuvasive, Inc. 2,882
Nex-D2 Next Orthosurgical 2,765
AnyPlus Spinal Fixation System GS Medical Co., Ltd. 2,386

Showing 12 of 1,490. All products under Thoracolumbosacral Pedicle Screw System

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241892 2024-08-02

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-08-21 Class II Process change control Spinal fixation system implant screws marked “DNI” are not intended to be implanted and may not have been manufactured in accordance with released manufacturing specifications, and if implanted the screws may not have adequate strength or p 330
2023-11-28 Class II Process control Spinal fixation screws labeled as 8.5 mm diameter, 50 mm length were manufactured using an incorrect screw shank component, and so the labeling is incorrect because the affected screws are in fact 5.5 diameter, 45 mm length screws, which if 6

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker