Viper
VIPER 2 SYSTEM ROD, PRE-LORDOSED 140mm
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (3), Shandong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| APS Materials Suzhou | Suzhou | Jiangsu | Contract manufacturer | 18 |
| Zibo Dante Co., Ltd. | Zibo | Shandong | Contract manufacturer | 17 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Shanghai Reach Medical Instrument Co., Ltd. | Shanghai | Shanghai | Manufacturer | 30 |
| Changzhou Geasure Medical Apparatus AND Instruments Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 25 |
| Double Medical Technology Inc. | Xiamen | Fujian | Contract manufacturer | 14 |
Showing 12 of 15. All 15 manufacturers in China registered for Thoracolumbosacral Pedicle Screw System
Record
| Listed by | Depuy Spine, Inc., United States |
|---|---|
| FDA product code | NKB |
| Device type | Thoracolumbosacral Pedicle Screw System |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3070 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K071860 |
| Record published | 2015-09-24 |
| Record revised | 2024-07-23 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 186789230 | In distribution | |
| 186788050 | In distribution | |
| 186789110 | In distribution | |
| 186789040 | In distribution | |
| 186789120 | In distribution | |
| 186788140 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| The Jasper Spinal Fixation System | Gbs Commonwealth Co., Ltd. | 32,491 |
| Invictus | Alphatec Spine, Inc. | 4,722 |
| Vital Spinal Fixation System | Highridge Medical, LLC | 4,422 |
| Innoverse Spinal System | CG MedTech Co., Ltd. | 4,240 |
| 4CIS® Chiron Spinal Fixation System | Alpha AI Co., Ltd. | 3,787 |
| LnK Spinal Fixation System | L&K Biomed Co., Ltd. | 3,522 |
| Hedjet System | Medyssey Co., Ltd. | 3,438 |
| Anax™ 5.5 Spinal System | CG MedTech Co., Ltd. | 3,424 |
| Mega Plus MIS Spine System | BK Meditech Co., Ltd. | 3,396 |
| ReLine | Nuvasive, Inc. | 2,882 |
| Nex-D2 | Next Orthosurgical | 2,765 |
| AnyPlus Spinal Fixation System | GS Medical Co., Ltd. | 2,386 |
Showing 12 of 1,490. All products under Thoracolumbosacral Pedicle Screw System
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K142185 | 2014-11-19 |
| K111136 | 2012-06-14 |
| K121020 | 2012-05-03 |
| K110216 | 2011-04-01 |
| K103133 | 2011-01-18 |
| K101993 | 2010-12-07 |
| K102701 | 2010-10-20 |
| K101933 | 2010-10-18 |
| K092473 | 2009-11-25 |
| K092626 | 2009-09-25 |
| K090648 | 2009-06-10 |
| K090799 | 2009-04-22 |
| K090230 | 2009-03-06 |
| K082942 | 2008-10-31 |
| K081898 | 2008-09-10 |
| K082195 | 2008-09-03 |
| K081252 | 2008-05-30 |
| K073562 | 2008-05-15 |
| K080313 | 2008-05-08 |
| K073364 | 2008-04-04 |
| K073126 | 2007-12-06 |
| K070387 | 2007-09-18 |
| K071860 | 2007-08-01 |
| K063772 | 2007-07-10 |
| K063741 | 2007-01-17 |
| K063156 | 2006-11-22 |
| K061520 | 2006-06-23 |
| K051024 | 2005-07-06 |
| K041801 | 2004-09-08 |
| K033901 | 2004-03-31 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Depuy Spine, Inc. | 510(k) number | 2015-04-21 | Class II | Process design | Device does not mate as intended. | 183 devices | 2018-10-03 |
Recalls
9 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 2013-12-24 | |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 36 units | 2013-12-24 |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 34 units | 2013-12-24 |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 23 units | 2013-12-24 |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the ilium. VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head. | 10 units | 2013-12-24 |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 34 uits | 2013-12-24 |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 2 units | 2013-12-24 |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 24 units | 2013-12-24 |
| 2012-11-07 | Class II | Component change control | Polyaxial screws 8x 80 and larger may disassociate when inserting in the Ilium., VIPER large diameter long screws in high-torque circumstances, the screw shank has the potential to separate from the polyaxial head | 6 units | 2013-12-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.