Echo BI-Metric Microplasty HIP Stem

4 catalogue numbers from 110025583, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
4catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code PBI
Manufacturer City Province Registered as Device types
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for Echo BI-Metric Microplasty HIP Stem
Listed by Biomet Orthopedics, United States
FDA product code PBI
Device type Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
Device class Class 2
Regulation 21 CFR 888.3310
510(k) K143009
Record published 2018-12-19
Record revised 2025-05-30 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Echo BI-Metric Microplasty HIP Stem
Catalogue number Size Status
110025583 SIZE 17 119MM In distribution
110025583 Size 17 X 119 mm In distribution
110025578 SIZE 12 106.5MM In distribution
110025755 Size 7-10 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
G7® Biomet Orthopedics 45
G7 Acetabular Liner Biomet Orthopedics 37
Arcos® One-Piece Revision System Biomet Orthopedics 17
G7® Acetabular System Biomet Orthopedics 13
G7 Osseoti Acetabular Shell Biomet Orthopedics 8
Sirius® Biomet Orthopedics 6
G7® Revision Acetabular System Zimmer, Inc. 5
G7 Provisional Neutral Liner Biomet Orthopedics 4
G7® Freedom® Vivacit-E® Zimmer, Inc. 4
Sirius HIP System Biomet Orthopedics 3
G7 Type 12 / 14 Provisional Head Biomet Orthopedics 3
Echo BI-Metric Microplasty HIP System Biomet Orthopedics 3

Showing 12 of 34. All products under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer