G7 Type 12 / 14 Provisional Head

3 catalogue numbers from 010002537, listed by Biomet Orthopedics, United States, under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
3catalogue numbers in this listing

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code PBI
Manufacturer City Province Registered as Device types
APS Materials Suzhou Suzhou Jiangsu Contract manufacturer 18
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54

Record

Regulatory record for G7 Type 12 / 14 Provisional Head
Listed by Biomet Orthopedics, United States
FDA product code PBI
Device type Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
Device class Class 2
Regulation 21 CFR 888.3310
510(k) K121874
Record published 2016-10-26
Record revised 2025-05-30 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number, manufacturing date

Catalogue Numbers

Catalogue numbers for G7 Type 12 / 14 Provisional Head
Catalogue number Size Status
010002537 32MM, -4MM NECK LENGTH In distribution
010002534 32MM, +8MM NECK LENGTH In distribution
010002539 36MM, +4MM NECK LENGTH In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
G7® Biomet Orthopedics 45
G7 Acetabular Liner Biomet Orthopedics 37
Arcos® One-Piece Revision System Biomet Orthopedics 17
G7® Acetabular System Biomet Orthopedics 13
G7 Osseoti Acetabular Shell Biomet Orthopedics 8
Sirius® Biomet Orthopedics 6
G7® Revision Acetabular System Zimmer, Inc. 5
G7 Provisional Neutral Liner Biomet Orthopedics 4
Echo BI-Metric Microplasty HIP Stem Biomet Orthopedics 4
G7® Freedom® Vivacit-E® Zimmer, Inc. 4
Sirius HIP System Biomet Orthopedics 3
Echo BI-Metric Microplasty HIP System Biomet Orthopedics 3

Showing 12 of 34. All products under Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive

Recalls Naming This Product

3 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of G7 Type 12 / 14 Provisional Head
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer, Inc. 510(k) number 2022-08-25 Class II Under Investigation by firm The outer sterile package cavity has a corner wall thickness that is below the specification. The thin corner wall could potentially crack during transit. Potential risks include non-clinically or clinically significant extension of surgery 56 US
Biomet, Inc. 510(k) number 2014-05-07 Class II Use error Guide rod may fracture during impaction of the acetabular shell and be retained in the inserter or the patient and could result in a delay in surgery. 1047 total 2015-10-30
Biomet, Inc. 510(k) number 2014-05-07 Class II Use error Guide rod may fracture during impaction of the acetabular shell and be retained in the inserter or the patient and could result in a delay in surgery. 1047 total 2015-10-30

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer