Rounded Burr

2 catalogue numbers from Ø4.1 X 15 mm - Stem lenght 60 mm, listed by BRM Extremities SRL, Italy, under Burr, Orthopedic. 3 manufacturers in China are registered for this product code.

Femoral Head Remover

2 catalogue numbers from 425420, listed by Biomet Orthopedics, United States, under Extractor. 15 manufacturers in China are registered for this product code.

10mm PPK Flex/Ext Gap Checker

Catalogue number SSI005367, listed by Biomet Orthopedics, United States, under Template. 21 manufacturers in China are registered for this product code.

BI-Polar Modular

7 catalogue numbers from 31-401132, listed by Biomet Orthopedics, United States, under Template. 21 manufacturers in China are registered for this product code.

Bayonet Drill Ø4.5 X 50 Mm

2 catalogue numbers from T2282, listed by MPS Micro Precision Systems AG, Switzerland, under Bit, Drill. 27 manufacturers in China are registered for this product code.

Pilling

5 catalogue numbers from IPN020014, listed by Teleflex Medical LLC, United States, under Awl. 13 manufacturers in China are registered for this product code.

Rigid Drill

11 catalogue numbers from 78202417, listed by implantcast GmbH, Germany, under Reamer. 23 manufacturers in China are registered for this product code.

Large Qwix®

The hexagonal cannulated screwdriver axis, with a 6.0mm diameter tri shank attachment, is used to implant or explant the 7.5mm screws.

Remedy Stem Size 12 Template

Catalogue number 112-34-1012, listed by Signature Orthopaedics PTY Limited, Australia, under Template. 21 manufacturers in China are registered for this product code.

Driver Shaft

Catalogue number 192-072-003, listed by Signature Orthopaedics PTY Limited, Australia, under Bit, Drill. 27 manufacturers in China are registered for this product code.

ACE Acetabular Reamer 37mm

Catalogue number 50141037, listed by Incipio Devices, United States, under Reamer. 23 manufacturers in China are registered for this product code.

Modular

2 catalogue numbers from 31-475629, listed by Biomet Orthopedics, United States, under Reamer. 23 manufacturers in China are registered for this product code.

CPT®

3 catalogue numbers from 8334-65-04, listed by Zimmer, Inc., United States, under Awl. 13 manufacturers in China are registered for this product code.

Caliper

3 catalogue numbers from 3895, listed by Zimmer, Inc., United States, under Caliper. 8 manufacturers in China are registered for this product code.

Parallel Wire / Drill Guide

Catalogue number 13509, listed by Biomet Orthopedics, United States, under Bit, Drill. 27 manufacturers in China are registered for this product code.

80mm Tib Drill

Catalogue number 122-22-0908, listed by Signature Orthopaedics PTY Limited, Australia, under Bit, Drill. 27 manufacturers in China are registered for this product code.

MP Monoblock – Instruments

Catalogue number 136-203/00, listed by Waldemar Link GmbH & Co. KG, Germany, under Screwdriver. 18 manufacturers in China are registered for this product code.

Template

Radiographic Transparency FOR Biomet 3I Parallel Walled Implants

SLX Insertion Tool

Catalogue number 6004, listed by Interventional Spine, Inc., United States, under Screwdriver. 18 manufacturers in China are registered for this product code.

Burr Fine 15MM

Catalogue number 19761, listed by Biopro, Inc., United States, under Burr, Orthopedic. 3 manufacturers in China are registered for this product code.

Drill Bit

Catalogue number 111-165, listed by Jeil Medical Corporation, South Korea, under Reamer. 23 manufacturers in China are registered for this product code.

VersiTomic Cannulated Drill, 2.4mm

Catalogue number 4732, listed by T.A.G Medical Products Agricultural Cooperative Association, under Reamer. 23 manufacturers in China are registered for this product code.

Unipolar Head

Catalogue number 01.08000.038, listed by Zimmer, Inc., United States, under Template. 21 manufacturers in China are registered for this product code.

Retaining Cap

Catalogue number 192-072-004, listed by Signature Orthopaedics PTY Limited, Australia, under Bit, Drill. 27 manufacturers in China are registered for this product code.

Lateralizer

Catalogue number 0806, listed by Advanced Orthopaedic Solutions, Inc., United States, under Orthopedic Manual Surgical Instrument. 53 manufacturers in China are registered for this product code.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer