Instrument

Restoration Modular Inst SYS Distal Stem Impactor / Reaming Post

Registry build 21.09.26
18manufacturers in China registered for this device type
18catalogue numbers in this listing
7recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (4), Shandong (2). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HWA
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
Guangzhou Aquila Precise Tools Limited Guangzhou Guangdong Contract manufacturer 28
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Xinhua Surgical Instrument Co., Ltd. Zibo Shandong Manufacturer 222
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53

Showing 12 of 18. All 18 manufacturers in China registered for Impactor

Record

Regulatory record for Instrument
Listed by Howmedica Osteonics Corp, United States
FDA product code HWA
Device type Impactor
Device class Class 1
Regulation 21 CFR 888.4540
Establishment Contract manufacturer, Contract steriliser, Specification developer, Manufacturer
Premarket notification Exempt
Record published 2017-11-13
Record revised 2026-02-09 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Instrument
Catalogue number Size Status
6541-4-812 In distribution
I-K2032FI00 In distribution
6541-7-811 In distribution
6543-4-600 In distribution
7000-5529 In distribution
I-K3047IM30 In distribution
6541-4-813 In distribution
7000-5525 In distribution
6278-1-300 In distribution
6541-4-811 In distribution
5650-4-811 In distribution
5650-4-812 In distribution
6543-6-129 In distribution
7004-0100 In distribution
7000-5526 In distribution
I-K0598PI00 In distribution
6543-6-128 In distribution
I-K3506KPIS In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
R3 Smith & Nephew, Inc. 153
Conserve® Microport Orthopedics Inc. 76
DJO Surgical Encore Medical, L.P. 73
Impactor Synthes Gmbh 56
Innomed, Inc. Innomed, Inc. 53
Impactor Zimmer, Inc. 50
Impactor Zimmer Trabecular Metal Technology, Inc. 43
iNSitu™ Hip System Nextstep Arthropedix 41
Apex Knee System Omni Life Science, Inc. 40
DJO Surgical DJO, LLC 36
Evolution® Microport Orthopedics Inc. 35
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 35

Showing 12 of 825. All products under Impactor

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-08-18 Class II Nonconforming Material/Component Stryker Orthopaedics has received reports of the thread length protruding past the dome of the acetabular trial or implant for the Trident Universal Impactor/Positioner. 3,768 units 2018-08-01
2013-09-30 Class II Device Design Stryker has received complaints associated with cracks and/or fracture of the Ball Impactor Tip and Rim Impactor Tip Instruments. 1,024 units 2016-10-19
2013-09-30 Class II Device Design Stryker has received complaints associated with cracks and/or fracture of the Ball Impactor Tip and Rim Impactor Tip Instruments. 1,690 units 2016-10-19
2008-07-02 Not classified Component design/selection Stryker Orthopaedics became aware that there is a potential inability to release the Scorpio Series 7000 Tibial Impactor/Extractor from a tibial baseplate during use. 5126 2012-08-17
2006-04-27 Not classified Nonconforming Material/Component The Lateral Decubitus Alignment Guide either did not assemble to its mating part, the Curved Impaction Handle, or partially engages the handle, but does not fully lock. 61 units 2009-10-15
2005-02-23 Not classified Device Design Insertion/Removal Difficulties: The Baseplate Impactor/Extractor may not assemble/disassemble easily to the baseplate. 293 total units 2008-05-30
2003-04-28 Not classified Other The ball retaining sleeve on the Trident Insert Impactor can possibly disassemble. 1758 2003-11-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer