DR 100s

Mobile DR

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
5recalls on this code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code IZL
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
Suzhou Powersite Electric Co., Ltd. Suzhou Jiangsu Manufacturer 2

Record

Regulatory record for DR 100s
Listed by Agfa Healthcare Inc., Canada
FDA product code IZL
Device type System, X-Ray, Mobile
Device class Class 2
Regulation 21 CFR 892.1720
Establishment Specification developer, Manufacturer
510(k) K191884
Record published 2019-09-14
Record revised 2023-07-18 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for DR 100s
Catalogue number Size Status
6013/100 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 27
AcuityPDR RadmediX, LLC 24
Sedecal Sedecal., Sa. 20
Drgem Drgem Corporation 10
DRX-Revolution Mobile X-ray System Carestream Health, Inc. 7
MinXray Minxray, Inc. 6
System, X-Ray, Mobile Ecotron Co., Ltd. 6
MobileDaRt Evolution Shimadzu Corp. 5
Nomad MD™ handheld X-ray system Aribex, Inc. 5
Portable X-ray Unit Ajex Meditech., Ltd. 5
Diagnostic X-ray Unit Poskom Co., Ltd. 4
FDR Aqro Fujifilm Corporation 4

Showing 12 of 75. All products under System, X-Ray, Mobile

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-01-20 Class II Other The DX-D100 User Manual already contained information about to move a DX-D100 mobile unit manually by using an Allen wrench, but did not indicate where the Allen wrench should be stored. 308 2017-04-10
2015-05-29 Class II Other When using the DX-D 100 unit, sporadic unintended movements caused by an electrostatic discharge of the unit to the ground may occur. 233 units 2017-01-18
2014-06-06 Class II Use error When liquid comes in contact with the DX-D 100 touch screen, the device may incorrectly recognize this as user input altering device settings. 216 units 2016-06-27
2014-05-13 Class III Labeling mix-ups Unit was mislabeled with a factory label showing 32 KW output power. 1 2014-08-13
2013-05-15 Class II Under Investigation by firm Customers could potentially experience intermittent, unintended and illogical movement when using the product. 104 2014-12-31

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker