DRX Revolution Nano Mobile X-Ray System

DRX Revolution Nano is a mobile X-ray system for radiographic examinations of pediatric and adult patients throughout treatment areas. It provides diagnostic image acquisition outside a…

Registry build 21.09.26

DRX Revolution Nano is a mobile X-ray system for radiographic examinations of pediatric and adult patients throughout treatment areas. It provides diagnostic image acquisition outside a fixed X-ray room.

The self-contained system combines an X-ray generator, image receptors, display and acquisition software. It supports digital radiography and can also expose computed-radiography storage-phosphor plates or film cassettes.

Listed Item

DRX-Revolution Nano Mobile X-RAY System

Imaging Configuration

The modified system uses a 5.3 kW generator with corresponding X-ray tube and embedded-software changes. Its mobile configuration brings the acquisition equipment to the patient treatment area.

5manufacturers in China registered for this device type
1catalogue number
7510(k) clearances naming this product code
13recalls on this code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code IZL
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
Suzhou Powersite Electric Co., Ltd. Suzhou Jiangsu Manufacturer 2

Record

Regulatory record for DRX Revolution Nano Mobile X-ray System
Listed by Carestream Health, Inc., United States
FDA product code IZL
Device type System, X-Ray, Mobile
Device class Class 2
Regulation 21 CFR 892.1720
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K173924
Record published 2018-03-07
Record revised 2018-07-06 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for DRX Revolution Nano Mobile X-ray System
Catalogue number Size Status
DRX Revolution Nano Mobile X-ray System In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 27
AcuityPDR RadmediX, LLC 24
Sedecal Sedecal., Sa. 20
Drgem Drgem Corporation 10
DRX-Revolution Mobile X-ray System Carestream Health, Inc. 7
MinXray Minxray, Inc. 6
System, X-Ray, Mobile Ecotron Co., Ltd. 6
MobileDaRt Evolution Shimadzu Corp. 5
Nomad MD™ handheld X-ray system Aribex, Inc. 5
Portable X-ray Unit Ajex Meditech., Ltd. 5
Diagnostic X-ray Unit Poskom Co., Ltd. 4
FDR Aqro Fujifilm Corporation 4

Showing 12 of 75. All products under System, X-Ray, Mobile

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253185 2026-03-11
K241505 2024-12-10
K213568 2022-03-23
K191025 2019-05-17
K173924 2018-02-05
K170755 2017-06-21
K120062 2012-04-13

Recalls

13 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-10-02 Class II Component design/selection There is a potential for unexpected failure of the electrical components within the Carestream Health Inc. generator installed in your DRX-Revolution Mobile X-ray System(s). This can lead to temporary and self contained thermal overload wit 2402 systems
2023-10-02 Class II Component design/selection Unexpected failure of electrical components within the CPI generator. 3,961 units
2017-05-25 Class II Process control Carestream found a single unit where four screws in the assembly were not applied in the manufacturing process. This could result in separation of the tube and yoke assembly. Domestic: 1449 units; Foreign: 1416 units 2018-06-13
2017-01-12 Class II Device Design The firm received a complaint alleging that a DRX Revolution System could not be stopped when applying the brake. The Revolution crashed into an elevator. US: 1403 units; Foreign: 1370 units 2018-06-13
2014-11-25 Class II Device Design While servicing a unit at a customer site, a field engineer discovered a broken bolt from the carriage assembly. Carestream has identified an issue related to the DRX-Revolution Mobile X-Ray System in which bolts that secure the x-ray tube 629 units (Domestic: 358 units; Foreign: 271 units) 2016-06-06
2013-11-25 Class II Nonconforming Material/Component Carestream Health Inc. has issued a recall for the Carestream DRX-Evolution (FF WS and CSJ WS) and the Kodak DirectView DR 7500 System due to the potential for unexpected device movement. 493 units Total (107 units domestically & 386 units internat 2016-06-30
2013-11-25 Class II Nonconforming Material/Component Carestream Health Inc. has issued a recall for the Carestream DRX-Evolution (FF WS and CSJ WS) and the Kodak DirectView DR 7500 System due to the potential for unexpected device movement. 840 units Total (181 units domestically & 659 units internat 2016-06-30
2013-11-25 Class II Nonconforming Material/Component Carestream Health Inc. has issued a recall for the Carestream DRX-Evolution (FF WS and CSJ WS) and the Kodak DirectView DR 7500 System due to the potential for unexpected device movement. 675 units Total (145 units domestically & 530 units internat 2016-06-30
2013-08-29 Class II Software design Carestream Health Inc. has conducted a voluntary field action which includes the installation of a software patch on the following: DRX-Revolution Mobile X-Ray, DRX-Mobile and DRX Transportable Systems with DirectView Version 5.5 and 5.6 co 190 units 2016-06-28
2013-08-29 Class II Radiation Control for Health and Safety Act It was discovered that Carestream received a report from a customer that 2 different patients were re-exposed due to the fact that the processed images were not able to be found in the system. 310 systerms domestically 2015-11-18
2013-07-26 Class II Software design During an audit, Carestream discovered a DRX-1 System that captured an image which displayed an artifact. This issue was discovered in manufacturing. It occurs when the DRX product console software is updated to v5.6b software and the det 23 units installed total (11 domestically & 12 international 2016-05-25
2013-06-19 Class II Device Design Carestream Health Inc. is conducting a recall for the Column end Cover present on the DRX Revolution Mobile X-Ray System due to the cover dislodging from the column. 331 units 2016-05-20
2013-06-06 Class II Device Design Carestream Health Inc. is recalling the power plug on their DRX-Revolution Mobile X-Ray System due to the item generating sparks and becoming warm to touch. 180 units 2016-05-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer