Micro-X

The device is designed to perform radiographic x-ray examinations on pediatric and adult patients, in all patient treatment areas

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code
10recalls on this code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code IZL
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
Suzhou Powersite Electric Co., Ltd. Suzhou Jiangsu Manufacturer 2

Record

Regulatory record for Micro-X
Listed by Micro-X Ltd, Australia
FDA product code IZL
Device type System, X-Ray, Mobile
Device class Class 2
Regulation 21 CFR 892.1720
Establishment Contract manufacturer, Manufacturer
510(k) K201488
Record published 2020-08-31

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment atmospheric pressure 70 to 106 KiloPascal; Handling environment humidity 30 to 60 % RH; Handling environment temperature 10 to 30 °C; Storage environment atmospheric pressure 50 to 106 KiloPascal; Storage environment humidity 10 to 86 % RH; Storage environment temperature -20 to 55 °C

Catalogue Numbers

Catalogue numbers for Micro-X
Catalogue number Size Status
Rover In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 27
AcuityPDR RadmediX, LLC 24
Sedecal Sedecal., Sa. 20
Drgem Drgem Corporation 10
DRX-Revolution Mobile X-ray System Carestream Health, Inc. 7
MinXray Minxray, Inc. 6
System, X-Ray, Mobile Ecotron Co., Ltd. 6
MobileDaRt Evolution Shimadzu Corp. 5
Nomad MD™ handheld X-ray system Aribex, Inc. 5
Portable X-ray Unit Ajex Meditech., Ltd. 5
Diagnostic X-ray Unit Poskom Co., Ltd. 4
FDR Aqro Fujifilm Corporation 4

Showing 12 of 75. All products under System, X-Ray, Mobile

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K211423 2021-05-21
K201488 2020-07-17

Recalls

10 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-03-27 Class II Component design/selection X-Ray generator may malfunction resulting in the X-Ray being inoperable. 32 units
2025-04-04 Class II Device Design Potential for internal fastening mechanism within generator of mobile x-Ray to fail. 13 units
2025-04-04 Class II Device Design Potential for internal fastening mechanism within generator of mobile x-Ray to fail. 5 units
2025-03-28 Class II Device Design Potential for early life x-ray tube failure for mobile x-ray system due to excessive thermal load on the anode. 31 units
2025-03-28 Class II Device Design Potential for early life x-ray tube failure for mobile x-ray system due to excessive thermal load on the anode. 20 units
2024-10-23 Class II Device Design During internal testing it was found that if the system is Ready to expose and the hand switch is then dropped into the stowage unit such that it lands on the prep/expose switch, the prep switch can be activated for a very short time such t 23
2024-10-22 Class II Environmental control Mobile x-ray system receiving/storage(operation) requirements to be followed: Temp:14 to 131(50 to 86) degrees F, RH:10% to 86%(30% to 60%) allow condensation dry time, Atmospheric Pressure:50kPa to 106 kPa(70kPa to 106kPa), Altitude:-102ft 6
2023-11-28 Class II Device Design Mobile x-ray system can report and deliver a lower post-exposure mAs value than what set by the operator. 18
2023-05-31 Class II Software design Shots were terminated by the mAs integrator; however, the 4 ms exposure time did not allow enough tolerance to achieve diagnostic exposures due to variations in hardware and how different timers are started. 5
2022-08-31 Class II Process control Software calibration error with product equip with a Dose Area Product (DAP) meter. This results in the product displaying the incorrect DAP meter values which may impede radiation exposure management decisions 42 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.