Mobilett XP Hybrid
Catalogue number 01818454, listed by Siemens Healthcare Limited, Canada, under System, X-Ray, Mobile. 5 manufacturers in China are registered for this product code.
5manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code
Who Else Makes It
Concentrated in Beijing (2), Shanghai (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| Suzhou Powersite Electric Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Record
| Listed by | Siemens Healthcare Limited, Canada |
|---|---|
| FDA product code | IZL |
| Device type | System, X-Ray, Mobile |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1720 |
| Establishment | Contract manufacturer, Manufacturer, Exporter |
| 510(k) | K033238 |
| Record published | 2016-09-24 |
| Record revised | 2021-11-18 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 01818454 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Siui | Shantou Institute OF Ultrasonic Instruments Co., Ltd. | 27 |
| AcuityPDR | RadmediX, LLC | 24 |
| Sedecal | Sedecal., Sa. | 20 |
| Drgem | Drgem Corporation | 10 |
| DRX-Revolution Mobile X-ray System | Carestream Health, Inc. | 7 |
| MinXray | Minxray, Inc. | 6 |
| System, X-Ray, Mobile | Ecotron Co., Ltd. | 6 |
| MobileDaRt Evolution | Shimadzu Corp. | 5 |
| Nomad MD™ handheld X-ray system | Aribex, Inc. | 5 |
| Portable X-ray Unit | Ajex Meditech., Ltd. | 5 |
| Diagnostic X-ray Unit | Poskom Co., Ltd. | 4 |
| FDR Aqro | Fujifilm Corporation | 4 |
Showing 12 of 75. All products under System, X-Ray, Mobile
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K032280 | 2003-09-10 |
| K781705 | 1978-10-24 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2014-05-09 | Class II | Component design/selection | There is a potential fire hazard of certain Lithium-Ion batteries in the computers used in the original manufacturing or as spare parts between October 2010 and April 2011 for the Siemens Mobilett XP Digital mobile X-ray System, which might | 10 | 2014-12-15 |
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2010-10-04 | Not classified | Device Design | Units not equipped with protective plastic cover over electronics. | 177 units | 2012-09-29 |
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2010-10-04 | Not classified | Other | battery fuse | 170 units | 2012-09-29 |
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2007-03-21 | Not classified | Other | Mounting bolts for tank fork assembly and collimator flange may become loose. | 186 units | 2007-08-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.