Philips

Intended for use by a qualified/trained doctor or technologist on both adult and pediatric patients for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen,…

Registry build 21.09.26

Intended for use by a qualified/trained doctor or technologist on both adult and pediatric patients for taking diagnostic radiographic exposures of the skull, spinal column, chest, abdomen, extremities, and other body parts. Applications can be performed with patient sitting, standing or lying in the prone or supine positions. Not for mammography

5manufacturers in China registered for this device type
1catalogue number
17510(k) clearances naming this product code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code IZL
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Shantou Institute OF Ultrasonic Instruments Co., Ltd. Shantou Guangdong Contract manufacturer 8
Suzhou Powersite Electric Co., Ltd. Suzhou Jiangsu Manufacturer 2

Record

Regulatory record for Philips
Listed by Sedecal., Sa., Spain
FDA product code IZL
Device type System, X-Ray, Mobile
Device class Class 2
Regulation 21 CFR 892.1720
Record published 2019-08-09

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment atmospheric pressure 700 to 1060 millibar; Handling environment humidity 30 to 75 % RH; Handling environment temperature 10 to 35 °C; Storage environment atmospheric pressure 700 to 1060 millibar; Storage environment humidity 20 to 90 % RH; Storage environment temperature -10 to 40 °C

Catalogue Numbers

Catalogue numbers for Philips
Catalogue number Size Status
MobileDiagnost wDR 2.2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Siui Shantou Institute OF Ultrasonic Instruments Co., Ltd. 27
AcuityPDR RadmediX, LLC 24
Sedecal Sedecal., Sa. 20
Drgem Drgem Corporation 10
DRX-Revolution Mobile X-ray System Carestream Health, Inc. 7
MinXray Minxray, Inc. 6
System, X-Ray, Mobile Ecotron Co., Ltd. 6
MobileDaRt Evolution Shimadzu Corp. 5
Nomad MD™ handheld X-ray system Aribex, Inc. 5
Portable X-ray Unit Ajex Meditech., Ltd. 5
Diagnostic X-ray Unit Poskom Co., Ltd. 4
FDR Aqro Fujifilm Corporation 4

Showing 12 of 75. All products under System, X-Ray, Mobile

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K232185 2023-08-21
K222951 2022-11-21
K221803 2022-07-18
K212291 2021-09-14
K192936 2019-11-15
K192011 2019-09-25
K191813 2019-08-02
K173299 2018-01-26
K161345 2016-07-06
K141895 2014-09-18
K121410 2012-08-02
K101517 2011-08-05
K111725 2011-07-19
K103522 2011-01-26
K090322 2009-03-17
K043002 2004-11-18
K020436 2002-02-22

Recalls Naming This Product

3 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of Philips
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Sedecal S.A. UDI-DI 2025-06-10 Class II Device Design Sedecal sent an email to its consignees to remind the users that the equipment is not water-resistant and must be cleaned strictly according to the instructions in the manual, clearly outlining the possible consequences of improper cleaning 1198 units
Sedecal S.A. UDI-DI 2024-01-22 Class II Component design/selection Potential interference with the anti-fall system. 636 devices
Sedecal S.A. UDI-DI 2021-10-14 Class II Use error While cleaning or disinfecting the system, if the process is not followed as described in the manual and excessive liquid is used or sprayed directly on the system, it could cause a short circuit of the fine positioning control button. Thi 851 devices

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer