System, X-Ray, Mobile
Digital Upgrade Kit, no Detector
5manufacturers in China registered for this device type
1catalogue number
Who Else Makes It
Concentrated in Beijing (2), Shanghai (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Shantou Institute OF Ultrasonic Instruments Co., Ltd. | Shantou | Guangdong | Contract manufacturer | 8 |
| Suzhou Powersite Electric Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Record
| Listed by | GE Medical Systems, L.L.C. |
|---|---|
| FDA product code | IZL |
| Device type | System, X-Ray, Mobile |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1720 |
| 510(k) | K142383 |
| Record published | 2016-08-01 |
| Record revised | 2026-02-16 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5421698 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Siui | Shantou Institute OF Ultrasonic Instruments Co., Ltd. | 27 |
| AcuityPDR | RadmediX, LLC | 24 |
| Sedecal | Sedecal., Sa. | 20 |
| Drgem | Drgem Corporation | 10 |
| DRX-Revolution Mobile X-ray System | Carestream Health, Inc. | 7 |
| MinXray | Minxray, Inc. | 6 |
| System, X-Ray, Mobile | Ecotron Co., Ltd. | 6 |
| MobileDaRt Evolution | Shimadzu Corp. | 5 |
| Nomad MD™ handheld X-ray system | Aribex, Inc. | 5 |
| Portable X-ray Unit | Ajex Meditech., Ltd. | 5 |
| Diagnostic X-ray Unit | Poskom Co., Ltd. | 4 |
| FDR Aqro | Fujifilm Corporation | 4 |
Showing 12 of 75. All products under System, X-Ray, Mobile
Recalls Naming This Product
8 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Medical Systems, LLC | 510(k) number | 2026-06-05 | Class II | Process control | GE HealthCare has become aware that in certain Optima XR200/220/240amx systems that have had a column replacement completed, functional testing of the safety pawl may not have been performed to confirm proper assembly. If a failure of the i | 4 units | |
| GE Medical Systems, LLC | 510(k) number | 2026-06-05 | Class II | Process control | GE HealthCare has become aware that in certain Optima XR200/220/240amx systems that have had a column replacement completed, functional testing of the safety pawl may not have been performed to confirm proper assembly. If a failure of the i | 38 units | |
| GE Medical Systems, LLC | 510(k) number | 2024-11-25 | Class II | Component design/selection | GE HealthCare has become aware that in certain Optima XR200/220/240amx systems that have had a column replacement performed, some bolts used in the Column Safety mechanism can be missing. If these bolts are missing and a failure of the inte | 53 units | |
| GE Medical Systems, LLC | 510(k) number | 2024-11-25 | Class II | Component design/selection | GE HealthCare has become aware that in certain Optima XR200/220/240amx systems that have had a column replacement performed, some bolts used in the Column Safety mechanism can be missing. If these bolts are missing and a failure of the inte | 281 units | |
| GE Medical Systems, LLC | 510(k) number | 2015-12-23 | Class II | Device Design | Potential safety latch mechanism failure. The safety latch, within the column that supports the horizontal arm, is a backup in the unlikely event the primary safety cable breaks. A fall of the arm assembly could result in bodily harm to a | 2389 | 2016-09-07 |
| GE Medical Systems, LLC | 510(k) number | 2015-12-23 | Class II | Device Design | Potential safety latch mechanism failure. The safety latch, within the column that supports the horizontal arm, is a backup in the unlikely event the primary safety cable breaks. A fall of the arm assembly could result in bodily harm to a | 895 | 2016-09-07 |
| GE Medical Systems, LLC | 510(k) number | 2014-12-19 | Class II | Radiation Control for Health and Safety Act | An issue was identified with the mAs accuracy check performed on the system that could result in inaccuracies in the 10% to 20% range for exposure times longer than 15 msec. | 6 units in US | 2015-04-29 |
| GE Medical Systems, LLC | 510(k) number | 2014-12-19 | Class II | Radiation Control for Health and Safety Act | An issue was identified with the mAs accuracy check performed on the system that could result in inaccuracies in the 10% to 20% range for exposure times longer than 15 msec. | 6 units in US | 2015-04-29 |