CombiDiagnost R90

The CombiDiagnost R90 is a multi-functional general Radiography/Fluoroscopy (R/F) system.that includes - Adjustable Straps for Patient Support; - Adult headrest; - Ankle Clamps; - Arm…

Registry build 21.09.26

The CombiDiagnost R90 is a multi-functional general Radiography/Fluoroscopy (R/F) system.that includes – Adjustable Straps for Patient Support; – Adult headrest; – Ankle Clamps; – Arm Support; – Babix holder vertical stand; – Compression Belt (singles. pull); – Console trolles; – Detector Holder for Patient Bed; – Extra Stitching Ruler; – Hand grips (Pair of); – Handle; – Infusion bottle holder; – Leg Supports (Pair of); – Mattress GXR Systems; – Mobile Detector Holder; – Monitor Ceiling Suspension(Family); – Monitor CS for1 Monitor; – Monitor CS for2 Monitors; – Monitor CS for3 Monitors; – Monitor Trolley Family: – Monitor Trolley for 1 Monitor assembly; – Monitor Trolley for 2 Monitors assembly; – Patient Support for Stitching; – Rotable stool for footrest; – Shoulder supports (Pair of); – Side Bar; – Stretch Grip for VS/VM Stand

9manufacturers in China registered for this device type
2catalogue numbers in this listing
5510(k) clearances naming this product code
9recalls on this code

Who Else Makes It

Concentrated in Beijing (2), Guangdong (2), Shanghai (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code JAA
Manufacturer City Province Registered as Device types
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Ming FAI Enterprise International Co., Ltd. Kowloon Hong Kong Exporter 18
Ming FAI Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 17
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
Careray Digital Medical Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2

Record

Regulatory record for CombiDiagnost R90
Listed by Philips Medical Systems DMC GmbH, Germany
FDA product code JAA
Device type System, X-Ray, Fluoroscopic, Image-Intensified
Device class Class 2
Regulation 21 CFR 892.1650
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2021-02-04
Record revised 2026-05-22 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Latex Labelled latex-free
Label carries serial number
Storage Storage environment temperature -25 to 70 °C; Storage environment humidity 5 to 95 % RH; Storage environment atmospheric pressure 70 to 110 KiloPascal

Catalogue Numbers

Catalogue numbers for CombiDiagnost R90
Catalogue number Size Status
709031 In distribution
709030 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Preferred Medical Products, LLC Preferred Medical Products, LLC 324
Unbranded Advance Medical Designs, Inc. 301
N23 CCD System Nical SPA 57
N33 CCD System Nical SPA 36
Trinias Shimadzu Corp. 31
Custom Cover Advance Medical Designs, Inc. 15
Pulse Nuvasive, Inc. 15
Sonialvision G4 Shimadzu Corp. 13
LessRay Nuvasive, Inc. 13
Micro Kover Advance Medical Designs, Inc. 11
Stephanix Stephanix 10
Snap Kover Advance Medical Designs, Inc. 9

Showing 12 of 169. All products under System, X-Ray, Fluoroscopic, Image-Intensified

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K233945 2024-01-11
K232910 2023-10-19
K212837 2021-09-21
K203087 2020-12-03
K163210 2017-01-31

Recalls Naming This Product

5 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of CombiDiagnost R90
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Philips Medical Systems DMC GmbH UDI-DI 2025-10-01 Class II Device Design Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024
through June 2025 may be difficult to move vertically (i.e. additional force/physical exertion required
for manual movement) due to potenti
17 units
Philips North America LLC UDI-DI 2023-09-21 Class II Under Investigation by firm Potential for units suspended on the ceiling to fail and fall. 46 units
Philips Medical Systems Technologies Ltd UDI-DI 2022-02-11 Class II Software design While performing a fluoroscopy examination, there is a potential that the Radio Fluoroscopy (RF) viewer will also display a previous patient’s radiography images. If the issue occurs, there will be differences in image content, image format 86 units
Philips Medical Systems Technologies Ltd UDI-DI 2022-02-11 Class II Software design While performing a fluoroscopy examination, there is a potential that the Radio Fluoroscopy (RF) viewer will also display a previous patient’s radiography images. If the issue occurs, there will be differences in image content, image format 130 units
Philips North America LLC UDI-DI 2021-10-21 Class II Device Design If the system experiences an overvoltage / power surge it can cause a short circuit condition within the Main- cabinet. If this issue occurs, the user may experience an electrical fire within the cabinet, see or smell smoke emitting from th 512 units

Recalls

7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-10-01 Class II Device Design Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024
through June 2025 may be difficult to move vertically (i.e. additional force/physical exertion required
for manual movement) due to potenti
42 units
2025-10-01 Class II Device Design Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024
through June 2025 may be difficult to move vertically (i.e. additional force/physical exertion required
for manual movement) due to potenti
41 units
2021-05-19 Class II Radiation Control for Health and Safety Act Following a system restart where the Table Height 2 (TH2) is the default setting and then switched to Wallstand VS2, operators will see an incorrect orientation of image on the first examination due to an issue in the firmware of the Wallst 140 systems in total, (Updated 1/30/2023).
2020-07-22 Class II Radiation Control for Health and Safety Act Philips has become aware of a software issue, where the kV and mA values are not locked immediately but change when the collimator shutter position is changed directly after the Lock-In command. This software issue leads to an over or under 322 systems; 66 in US
2019-12-19 Class II Software design When using the Table Up/Down button, the system may experience Error 80, which locks the geometry in that specific state, requiring the intervention of a service Engineer. Additionally, the thermos switch, which handles power down of the un 116 2020-06-18
2019-12-19 Class II Software design When using the Table Up/Down button, the system may experience Error 80, which locks the geometry in that specific state, requiring the intervention of a service Engineer. Additionally, the thermos switch, which handles power down of the un 131 2020-06-18
2018-11-07 Class II Software design (manufacturing process) kV/mA lockin not functioning as specified which may result in the patient receiving an increased radiation dose. 146 2020-09-02
2012-03-09 Not classified Software design Underexposed image due to lag in switching between
auxiliaries
88 units 2013-05-23

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer