InSight 2
Catalogue number InSight 2, listed by Hologic, Inc., United States, under System, X-Ray, Fluoroscopic, Image-Intensified. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Beijing (2), Guangdong (2), Shanghai (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Ming FAI Enterprise International Co., Ltd. | Kowloon | Hong Kong | Exporter | 18 |
| Ming FAI Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 17 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Careray Digital Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Record
| Listed by | Hologic, Inc., United States |
|---|---|
| FDA product code | JAA |
| Device type | System, X-Ray, Fluoroscopic, Image-Intensified |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1650 |
| Establishment | Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K051025 |
| Record published | 2016-08-23 |
| Record revised | 2024-08-16 (version 5) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Handling environment temperature 16 to 30 °C; Storage environment temperature -20 to 50 °C |
| Distribution end date | 2020-01-01 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| InSight 2 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Preferred Medical Products, LLC | Preferred Medical Products, LLC | 324 |
| Unbranded | Advance Medical Designs, Inc. | 301 |
| N23 CCD System | Nical SPA | 57 |
| N33 CCD System | Nical SPA | 36 |
| Trinias | Shimadzu Corp. | 31 |
| Custom Cover | Advance Medical Designs, Inc. | 15 |
| Pulse | Nuvasive, Inc. | 15 |
| Sonialvision G4 | Shimadzu Corp. | 13 |
| LessRay | Nuvasive, Inc. | 13 |
| Micro Kover | Advance Medical Designs, Inc. | 11 |
| Stephanix | Stephanix | 10 |
| Snap Kover | Advance Medical Designs, Inc. | 9 |
Showing 12 of 169. All products under System, X-Ray, Fluoroscopic, Image-Intensified
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K051025 | 2005-05-13 |
| K974058 | 1998-01-12 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Hologic, Inc. | 510(k) number | 2013-04-25 | Class II | Software design | The audible alarm to alert the operator when cumulative irradiation time reaches five minutes is not accurate and the total cumulative irradiation time is not accurate. | 287 | 2014-08-21 |
| Hologic, Inc. | 510(k) number | 2013-04-25 | Class II | Software design | The audible alarm to alert the operator when cumulative irradiation time reaches five minutes is not accurate and the total cumulative irradiation time is not accurate. | 2780 | 2014-08-21 |
| Hologic, Inc. | 510(k) number | 2012-09-14 | Class II | Software design | InSight2, version 4.0 and 4.0.1 – DICOM images stored in PACS may be flipped 180around vertical axis. InSight FD, version 5.0.1 and 5.0.2 – DICOM images stored in PACS may be lipped 180 around vertical axis as well as 180 around a horizonta | 414 units | 2014-01-10 |
| Hologic, Inc. | 510(k) number | 2012-09-14 | Class II | Software design | Fluoroscan Mini C-Arm models -InSight2, version 4.0 and 4.0.1 – DICOM images stored in PACS may be flipped 180around vertical axis. InSight FD, version 5.0.1 and 5.0.2 – DICOM images stored in PACS may be lipped 180 around vertical axis as | 46 units | 2014-01-10 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2011-07-21 | Not classified | Nonconforming Material/Component | The Flex arm connector to C-arm can break and the C-arm that is supported by the flex arm may fall down | 540 units | 2012-06-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.