Intelli-C Left Side Suspended Table
The Intelli-C X-ray device is a multi-purpose - also sometimes known as a universal C-arm fluoroscopy system, designed for diagnostic medical imaging examinations, from barium studies to…
The Intelli-C X-ray device is a multi-purpose – also sometimes known as a universal C-arm fluoroscopy system, designed for diagnostic medical imaging examinations, from barium studies to interventional and angiography studies.
Who Else Makes It
Concentrated in Beijing (2), Guangdong (2), Shanghai (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Ming FAI Enterprise International Co., Ltd. | Kowloon | Hong Kong | Exporter | 18 |
| Ming FAI Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 17 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Careray Digital Medical Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
Record
| Listed by | Nrt – Nordisk Røntgen Teknik A/S |
|---|---|
| FDA product code | JAA |
| Device type | System, X-Ray, Fluoroscopic, Image-Intensified |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1650 |
| 510(k) | K173631 |
| Record published | 2019-06-01 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 03400010 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Preferred Medical Products, LLC | Preferred Medical Products, LLC | 324 |
| Unbranded | Advance Medical Designs, Inc. | 301 |
| N23 CCD System | Nical SPA | 57 |
| N33 CCD System | Nical SPA | 36 |
| Trinias | Shimadzu Corp. | 31 |
| Custom Cover | Advance Medical Designs, Inc. | 15 |
| Pulse | Nuvasive, Inc. | 15 |
| Sonialvision G4 | Shimadzu Corp. | 13 |
| LessRay | Nuvasive, Inc. | 13 |
| Micro Kover | Advance Medical Designs, Inc. | 11 |
| Stephanix | Stephanix | 10 |
| Snap Kover | Advance Medical Designs, Inc. | 9 |
Showing 12 of 169. All products under System, X-Ray, Fluoroscopic, Image-Intensified
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| NRT X-RAY A/S | 510(k) number | 2024-04-17 | Class II | Device Design | X-ray system C-arm may experience uncontrolled motion if 1) AC motor controller firmware has a faulty setting, 2) the Motor/gear assembly is worn, 3) CAT movement is driven at maximum speed and angulated more than 75 deg. from vertical, and | 35 |
| NRT X-RAY A/S | 510(k) number | 2023-04-27 | Class II | Device Design | There is a potential that the drive shaft in the detector up/down (IDE) movement of the X-Ray machine may break which causes the detector to move until it is stopped by the movement end-stop. | 32 units |
| NRT X-RAY A/S | 510(k) number | 2023-04-27 | Class II | Device Design | There is a potential that the drive shaft in the detector up/down (IDE) movement of the X-Ray machine may break which causes the detector to move until it is stopped by the movement end-stop. | 13 units |
| NRT X-RAY A/S | 510(k) number | 2022-01-21 | Class II | Process control | Friction rubber block in the clamping mechanism was missing in the Footrest. It may slip down along the patient table while in use with a patient. This accessory is designed to use with Intelli-C, Right and Intelli-C, Left. | 72 units |