C.Cam
Catalogue number c.cam Gamma Camera System, listed by Ddd-Diagnostic A/S, Denmark, under System, Tomography, Computed, Emission. 4 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Beijing (1), Shanghai (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Neusoft Positron Medical Systems Co., Ltd. | Shen Yang | Liaoning | Manufacturer | 1 |
Record
| Listed by | Ddd-Diagnostic A/S, Denmark |
|---|---|
| FDA product code | KPS |
| Device type | System, Tomography, Computed, Emission |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1200 |
| 510(k) | K031825 |
| Record published | 2016-11-20 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | manufacturing date, serial number |
| Sizes | Weight 1350 kg; height 169 cm; depth 229 cm; width 244 cm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| c.cam Gamma Camera System | Weight 1350 kg | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| NeuroQ | Syntermed, Inc. | 11 |
| Emory Cardiac Toolbox | Syntermed, Inc. | 10 |
| Discovery | GE Medical Systems, L.L.C. | 7 |
| uMI | Shanghai United Imaging Healthcare Co., Ltd. | 7 |
| Brightonix | Brightonix Imaging Inc. | 6 |
| UltraSPECT | Ultraspect USA, LLC | 5 |
| Discovery | G E Medical Systems Israel Ltd. | 5 |
| Veriton CT | Spectrum Dynamics Medical Ltd. | 5 |
| Cardius 2 | Digirad Corp. | 4 |
| Encompass™ SRS Fibreplast™ System | Qfix | 4 |
| Veriton NM | Spectrum Dynamics Medical Ltd. | 3 |
| Cedars-Sinai Cardiac Suite | Cedars Sinai Medical Center | 3 |
Showing 12 of 172. All products under System, Tomography, Computed, Emission
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K161674 | 2016-10-20 |
| K140206 | 2014-05-08 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2007-09-17 | Not classified | Software design | Unintended Motion: A hardware fault in the c.cam system can cause the system to experience unintended motion, thereby causing a collision hazard. | 486 units | 2009-01-09 |
| Siemens Medical Solutions USA, Inc. | 510(k) number | 2007-04-30 | Not classified | Other | Chair Breakage: Under extreme load, the chair back of the c.cam emission computed tomography system may bend and eventually break. This could be caused by the accumulated stress from heavy patients seating or stretching themselves in the c | 413 cameras | 2009-01-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.