The Cardiac Toolbox™ 4.2 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies…
The Cardiac Toolbox™ 4.2 is used to display gated wall motion and for quantifying parameters of left-ventricular perfusion and function from gated SPECT & PET myocardial perfusion studies and for the evaluation of dynamic PET studies. These parameters are: perfusion, ejection fraction, end-diastolic volume, end-systolic volume, myocardial mass, transient ischemic dilatation (TID), analysis of coronary blood flow and coronary flow reserve, and assessment of cardiac mechanic dyssynchrony. In addition, the program offers the capability of providing the following diagnostic information: computer assisted visual scoring, prognostic information, and expert system image interpretation. The program can also be used for the 3D alignment of coronary artery models from CT coronary angiography onto the left ventricular 3D epicardial surface and for generation of the short axis, vertical, and horizontal long axis tomograms from the SPECT raw data using either filtered backprojection (FBP) or iterative reconstruction (MLEM/OSEM). The Emory Cardiac Toolbox can be used with any of the following Myocardial SPECT Protocols: Same Day and Two Day Sestamibi, Dual-Isotope (Tc-99m/Tl-201), Tetrofosmin, and Thallium, Rubidium-82, Rubidium-82 with CT-based attenuation correction, N-13-ammonia, FDG protocols, and user defined normal databases. This program was developed to run in the.NET operating system environment which can be executed on any PC, any nuclear medicine computer system, or through a web browser. In addition, the program can be used for the decision support in interpretation and automatic structured reporting of the study. The program processes the studies automatically, however, user verification of output is required and manual processing capability is provided.
Who Else Makes It
Concentrated in Beijing (1), Shanghai (1), Guangdong (1).
Record
Regulatory record for Cardiac Toolbox | Listed by | Syntermed, Inc., United States |
| FDA product code | KPS |
| Device type | System, Tomography, Computed, Emission |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1200 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| Record published | 2026-07-02 |
Specifications
Specifications | MRI safety | Labeling does not contain MRI Safety Information |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.