CardioMD

Catalogue number CardioMD Gamma Camera System, listed by Ddd-Diagnostic A/S, Denmark, under System, Tomography, Computed, Emission. 4 manufacturers in China are registered for this product code.

Registry build 21.09.26
4manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code

Who Else Makes It

Concentrated in Beijing (1), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code KPS
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
Neusoft Positron Medical Systems Co., Ltd. Shen Yang Liaoning Manufacturer 1

Record

Regulatory record for CardioMD
Listed by Ddd-Diagnostic A/S, Denmark
FDA product code KPS
Device type System, Tomography, Computed, Emission
Device class Class 2
Regulation 21 CFR 892.1200
510(k) K011611
Record published 2018-02-09
Record revised 2019-08-22 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number
Sizes Width 284 cm; depth 150 cm; height 150 cm; weight 815 kg
Distribution end date 2018-07-04

Catalogue Numbers

Catalogue numbers for CardioMD
Catalogue number Size Status
CardioMD Gamma Camera System Width 284 cm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
NeuroQ Syntermed, Inc. 11
Emory Cardiac Toolbox Syntermed, Inc. 10
Discovery GE Medical Systems, L.L.C. 7
uMI Shanghai United Imaging Healthcare Co., Ltd. 7
Brightonix Brightonix Imaging Inc. 6
UltraSPECT Ultraspect USA, LLC 5
Discovery G E Medical Systems Israel Ltd. 5
Veriton CT Spectrum Dynamics Medical Ltd. 5
Cardius 2 Digirad Corp. 4
Encompass™ SRS Fibreplast™ System Qfix 4
Veriton NM Spectrum Dynamics Medical Ltd. 3
Cedars-Sinai Cardiac Suite Cedars Sinai Medical Center 3

Showing 12 of 172. All products under System, Tomography, Computed, Emission

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K161674 2016-10-20
K140206 2014-05-08

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of CardioMD
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Adac Labs 510(k) number 2004-06-21 Not classified Other Software problems may cause the detector head to drift unexpectedly 482 units 2005-12-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer