Discovery NM 530c
UFC Gantry Final Assembly
4manufacturers in China registered for this device type
1catalogue number
Who Else Makes It
Concentrated in Beijing (1), Shanghai (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Neusoft Positron Medical Systems Co., Ltd. | Shen Yang | Liaoning | Manufacturer | 1 |
Record
| Listed by | G E Medical Systems Israel Ltd. |
|---|---|
| FDA product code | KPS |
| Device type | System, Tomography, Computed, Emission |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1200 |
| 510(k) | K080124 |
| Record published | 2016-08-01 |
| Record revised | 2026-01-30 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| H3000SA | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| NeuroQ | Syntermed, Inc. | 11 |
| Emory Cardiac Toolbox | Syntermed, Inc. | 10 |
| Discovery | GE Medical Systems, L.L.C. | 7 |
| uMI | Shanghai United Imaging Healthcare Co., Ltd. | 7 |
| Brightonix | Brightonix Imaging Inc. | 6 |
| UltraSPECT | Ultraspect USA, LLC | 5 |
| Discovery | G E Medical Systems Israel Ltd. | 5 |
| Veriton CT | Spectrum Dynamics Medical Ltd. | 5 |
| Cardius 2 | Digirad Corp. | 4 |
| Encompass™ SRS Fibreplast™ System | Qfix | 4 |
| Veriton NM | Spectrum Dynamics Medical Ltd. | 3 |
| Cedars-Sinai Cardiac Suite | Cedars Sinai Medical Center | 3 |
Showing 12 of 172. All products under System, Tomography, Computed, Emission
Recalls Naming This Product
3 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| GE Medical Systems, LLC | UDI-DI | 2022-06-02 | Class II | Error in labeling | As a result of unclear guidance in the service manual, the table can drop during a specific service activity if the wrong screws are removed by the service personnel without the appropriate table supports in place resulting in injury to ser | 24,843 tables | |
| GE Medical Systems, LLC | 510(k) number | 2018-11-30 | Class II | Other | GE Healthcare has identified that a small number of Nuclear Medicine systems are operating without currently updated software. In a recent event, a patient s finger was injured during the Unload process while the automatic Unload feature wa | 526 total units | |
| GE Medical Systems, LLC | 510(k) number | 2013-01-09 | Class II | Device Design | GE Healthcare has recently become aware of an incident which caused a patient injury during an unload following an exam on a Ventri scanner. During a patient unload following a scan, the patients fingers may be pinched between the moving cr | 556 | 2013-08-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.