Discovery NM 530c

UFC Gantry Final Assembly

Registry build 21.09.26
4manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Beijing (1), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code KPS
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
Neusoft Positron Medical Systems Co., Ltd. Shen Yang Liaoning Manufacturer 1

Record

Regulatory record for Discovery NM 530c
Listed by G E Medical Systems Israel Ltd.
FDA product code KPS
Device type System, Tomography, Computed, Emission
Device class Class 2
Regulation 21 CFR 892.1200
510(k) K080124
Record published 2016-08-01
Record revised 2026-01-30 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Discovery NM 530c
Catalogue number Size Status
H3000SA In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
NeuroQ Syntermed, Inc. 11
Emory Cardiac Toolbox Syntermed, Inc. 10
Discovery GE Medical Systems, L.L.C. 7
uMI Shanghai United Imaging Healthcare Co., Ltd. 7
Brightonix Brightonix Imaging Inc. 6
UltraSPECT Ultraspect USA, LLC 5
Discovery G E Medical Systems Israel Ltd. 5
Veriton CT Spectrum Dynamics Medical Ltd. 5
Cardius 2 Digirad Corp. 4
Encompass™ SRS Fibreplast™ System Qfix 4
Veriton NM Spectrum Dynamics Medical Ltd. 3
Cedars-Sinai Cardiac Suite Cedars Sinai Medical Center 3

Showing 12 of 172. All products under System, Tomography, Computed, Emission

Recalls Naming This Product

3 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Discovery NM 530c
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems, LLC UDI-DI 2022-06-02 Class II Error in labeling As a result of unclear guidance in the service manual, the table can drop during a specific service activity if the wrong screws are removed by the service personnel without the appropriate table supports in place resulting in injury to ser 24,843 tables
GE Medical Systems, LLC 510(k) number 2018-11-30 Class II Other GE Healthcare has identified that a small number of Nuclear Medicine systems are operating without currently updated software. In a recent event, a patient s finger was injured during the Unload process while the automatic Unload feature wa 526 total units
GE Medical Systems, LLC 510(k) number 2013-01-09 Class II Device Design GE Healthcare has recently become aware of an incident which caused a patient injury during an unload following an exam on a Ventri scanner. During a patient unload following a scan, the patients fingers may be pinched between the moving cr 556 2013-08-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer