Nmct

NM CT 860 Gantry Final

Registry build 21.09.26
4manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Beijing (1), Shanghai (1), Guangdong (1).

Chinese manufacturers registered for FDA product code KPS
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8
Neusoft Positron Medical Systems Co., Ltd. Shen Yang Liaoning Manufacturer 1

Record

Regulatory record for Nmct
Listed by G E Medical Systems Israel Ltd.
FDA product code KPS
Device type System, Tomography, Computed, Emission
Device class Class 2
Regulation 21 CFR 892.1200
510(k) K173816
Record published 2018-04-23
Record revised 2026-01-30 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Nmct
Catalogue number Size Status
860 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
NeuroQ Syntermed, Inc. 11
Emory Cardiac Toolbox Syntermed, Inc. 10
Discovery GE Medical Systems, L.L.C. 7
uMI Shanghai United Imaging Healthcare Co., Ltd. 7
Brightonix Brightonix Imaging Inc. 6
UltraSPECT Ultraspect USA, LLC 5
Discovery G E Medical Systems Israel Ltd. 5
Veriton CT Spectrum Dynamics Medical Ltd. 5
Cardius 2 Digirad Corp. 4
Encompass™ SRS Fibreplast™ System Qfix 4
Veriton NM Spectrum Dynamics Medical Ltd. 3
Cedars-Sinai Cardiac Suite Cedars Sinai Medical Center 3

Showing 12 of 172. All products under System, Tomography, Computed, Emission

Recalls Naming This Product

10 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Nmct
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
GE Medical Systems Israel, Functional Imaging 510(k) number 2022-12-19 Class I Process control A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury. 380 units
GE Medical Systems, LLC 510(k) number 2021-02-07 Class II Device Design GE Healthcare has become aware of a potential issue on 800 family NM/CT
Scanners that could cause a shift in CT radiation exposure range of up to 5cm compared to the intended radiation exposure range of the planned scan under specific workf
242 in total (17 units US)
GE Medical Systems, LLC 510(k) number 2021-02-07 Class II Device Design GE Healthcare has become aware of a potential issue on 800 family NM/CT
Scanners that could cause a shift in CT radiation exposure range of up to 5cm compared to the
intended radiation exposure range of the planned scan under specific workf
242 in total (17 units US)
GE Medical Systems, LLC 510(k) number 2020-12-10 Class II Process control GE Healthcare has become aware that rotor bearing screws were found loose on one detector in the field, leading to the release of one of the four rotor bearings in the detector. 24 units 2026-08-21
GE Medical Systems, LLC 510(k) number 2020-12-10 Class II Process control GE Healthcare has become aware that rotor bearing screws were found loose on one detector in the field, leading to the release of one of the four rotor bearings in the detector. 12 units 2026-08-21
GE Medical Systems, LLC 510(k) number 2020-08-14 Class II Use error Rotor bearing screws were found loose on
detector.
25 units 2021-05-06
GE Medical Systems, LLC 510(k) number 2020-08-14 Class II Use error Rotor bearing screws were found loose on
detector.
4 units 2021-05-06
GE Medical Systems, LLC 510(k) number 2019-03-20 Class II Device Design During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy. 37 units 2020-10-05
GE Medical Systems, LLC 510(k) number 2019-03-20 Class II Device Design During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy. 31 units 2020-10-05
GE Medical Systems, LLC 510(k) number 2019-03-20 Class II Device Design During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy. 6 units 2020-10-05

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.