Solstat™ Immobilization System
2 catalogue numbers from CHS05, listed by Medtec LLC, United States, under System, Nuclear Magnetic Resonance Imaging. 12 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shanghai (3), Beijing (2), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Chenguang Medical Technologies Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 2 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Shanghai United Imaging Healthcare Co., Ltd. | Shanghai | Shanghai | Manufacturer | 12 |
| Siemens Shenzhen Magnetic Resonance Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| GE Healthcare (Tianjin) Company Limited | Tianjin | Tianjin | Specification developer | 5 |
| GE Healthcare (China) Co., Ltd. – Tianjin | Tianjin | Tianjin | Specification developer | 3 |
| Shenzhen RF Tech Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 2 |
| Shanghai Chenshi Medical Instruments Co., Ltd. | Shanghai | Shanghai | Exporter | 2 |
| MRI Division, Beijing Wandong Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 1 |
| Jiangsu Magspin Instrument Co., Ltd. | Kunshan | Jiangsu | Manufacturer | 1 |
| Xingaoyi Medical Equipment Co., Ltd. | Yuyao | Zhejiang | Manufacturer | 1 |
| Sino Canada Health Engineering Research Institute (Hefei) Ltd. (Scheri) | Hefei | Anhui | Complaint-file establishment | 1 |
Record
| Listed by | Medtec LLC, United States |
|---|---|
| FDA product code | LNH |
| Device type | System, Nuclear Magnetic Resonance Imaging |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1000 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K182079 |
| Record published | 2019-01-07 |
| Record revised | 2019-05-30 (version 2) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date, serial number |
| Sizes | Length 11.35 in; width 9.74 in |
| Distribution end date | 2024-04-05 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CHS05 | Length 11.35 in | In distribution |
| CHS14 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Ingenia | Philips Medical Systems Nederland B.V. | 72 |
| System, Nuclear Magnetic Resonance Imaging | GE Medical Systems, L.L.C. | 40 |
| System, Nuclear Magnetic Resonance Imaging | Medtronic Navigation, Inc. | 23 |
| Uni-frame® Thermoplastic | Medtec LLC | 19 |
| Positioning Cushion | Medtec LLC | 18 |
| Posicast® Thermoplastic | Medtec LLC | 18 |
| System, Nuclear Magnetic Resonance Imaging | GE Healthcare (Tianjin) Company Limited | 16 |
| Invivo | Philips DS North America LLC | 15 |
| Type-S™ Thermoplastic | Medtec LLC | 14 |
| Aperto Lucent | Fujifilm Corporation | 13 |
| MRI Integral “T” with Check Valve for Medrad® Spectris MR Injector | Bayer Medical Care Inc. | 11 |
| PPG Finger Band | IVY Biomedical Systems, Inc. | 11 |
Showing 12 of 478. All products under System, Nuclear Magnetic Resonance Imaging
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K111340 | 2011-06-28 |
| K093738 | 2010-05-14 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Medtec LLC | 510(k) number | 2019-04-15 | Class II | Device Design | There is a potential for movement of the Solstice Tilting Head Fixation System during patient setup and/or treatment. | 28 units | 2020-10-05 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P860010 | 1988-06-12 | INSTRUMENTARIUM ULF MR IMAGING SYSTEM | Palomex Instrumentarium Corp. |
| P860062 | 1988-05-25 | RESONEX RX4000{TM} MAGNETIC RESONANCE IMAGING SYST | Resonex, Inc. |
| P850043 | 1987-12-30 | MAGNISCAN 5000 MRI SYSTEM | Thomson-Cgr Medical Corp. |
| P830074 | 1987-11-25 | GE SIGNA MAGNETIC RESONANCE DIAGNOSTIC IMAGING SYS | General Electric Co. |
| P840063 | 1987-08-11 | GYROSCAN(TM) | Philips Medical Systems Technologies Ltd |
| P840007 | 1987-04-02 | GYREX, MODELS S3500 & S5000 | Elscint, Inc. |
| P830076 | 1986-10-08 | FONAR NMR WHOLE BODY SCANNER BETA 3000 | Fonar Corp. |
| P830052 | 1986-05-28 | NUCLEAR MAGNETIC RESONANCE SCANNER MODELS NMR 1000 | Philips Medical Systems (Cleveland), Inc. |
| P830051 | 1986-04-30 | TESLACON(TM) NMR IMAGING SYSTEM | Technicare Corp. |
| P830053 | 1985-12-18 | DIASONICS NMR IMAGING SYSTEM | Diasonics, Inc. |
| P830081 | 1985-06-06 | MAGNETOM | Siemens Healthcare Limited |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.