Catheterization Table

Catalogue number CAT-860B, listed by Canon Inc., Japan, under Interventional Fluoroscopic X-Ray System. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (2), Guangdong (1).

Chinese manufacturers registered for FDA product code OWB
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8

Record

Regulatory record for Catheterization Table
Listed by Canon Inc., Japan
FDA product code OWB
Device type Interventional Fluoroscopic X-Ray System
Device class Class 2
Regulation 21 CFR 892.1650
Establishment Contract manufacturer, Specification developer, Manufacturer
510(k) K210900
Record published 2025-03-13
Record revised 2026-03-20 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries serial number

Catalogue Numbers

Catalogue numbers for Catheterization Table
Catalogue number Size Status
CAT-860B In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
TrackX Trackx Technology Inc. 86
Trinias Shimadzu Corp. 54
Allura Xper FD Philips Medical Systems Nederland B.V. 21
Azurion Philips Medical Systems Nederland B.V. 19
LessRay Nuvasive, Inc. 16
Intelli-C Accessory Nrt – Nordisk Røntgen Teknik A/S 13
Pulse Nuvasive, Inc. 12
O-ARM® Medtronic Navigation, Inc. 11
Genoray Genoray Co., Ltd. 10
Fujifilm Healthcare Americas Corporation A.T.S. Applicazione Tecnologie Speciali SRL 7
Fujifilm Medical Systems U.S.A. Inc. A.T.S. Applicazione Tecnologie Speciali SRL 6
Stephanix A.T.S. Applicazione Tecnologie Speciali SRL 6

Showing 12 of 122. All products under Interventional Fluoroscopic X-Ray System

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252503 2026-04-30
K232298 2024-04-26
K200887 2020-04-15
K171194 2017-05-24

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Catheterization Table
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Canon Medical System, USA, Inc. 510(k) number 2026-08-04 Class II Process control Due to the fixing screws of ceiling movement gear in ceiling suspended arm that are part of the X-ray interventional systems may become loose. 10 systems
Canon Medical System, USA, Inc. 510(k) number 2025-12-19 Class II Process design It has been discovered that there is a possibility that the fixing screws of the ceiling movement gear in the ceiling suspended arm that are part of the X-ray interventional
systems may become loose. As a result, ceiling lateral movement m
172 units
Canon Medical System, USA, Inc. 510(k) number 2025-09-02 Class II Radiation Control for Health and Safety Act It has been found that when SPOT Fluoro is first turned on, the default ROI is selected and the collimator blades move to the boundary of the ROI, and the static image is overlayed around the ROI,
covering the collimated area. If the custom
8
Canon Medical System, USA, Inc. 510(k) number 2023-11-15 Class II Component change control VAREX changed the manufacturing of the internal board, and the detectors displayed abnormal images. Internal board of the X-ray flat panel detector may display abnormal images, such as horizontal stripes, which may lead to the inability to 1
Canon Medical System, USA, Inc. 510(k) number 2023-06-22 Class II Nonconforming Material/Component The C-arm, used to set the position and angle of the x-ray exposure field, may not function due to the tableside console PWB, which needs replacement. There may be a delay in the procedure, but procedures can continue using the operators co 12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer