Interventional Angiography System

Catalogue number INFX-8000V, listed by Canon Inc., Japan, under Interventional Fluoroscopic X-Ray System. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code

Who Else Makes It

Concentrated in Beijing (2), Shanghai (2), Guangdong (1).

Chinese manufacturers registered for FDA product code OWB
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Shanghai United Imaging Healthcare Co., Ltd. Shanghai Shanghai Manufacturer 12
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10
Siemens Shenzhen Magnetic Resonance Ltd. Shenzhen Guangdong Contract manufacturer 8

Record

Regulatory record for Interventional Angiography System
Listed by Canon Inc., Japan
FDA product code OWB
Device type Interventional Fluoroscopic X-Ray System
Device class Class 2
Regulation 21 CFR 892.1650
Establishment Contract manufacturer, Specification developer, Manufacturer
510(k) K081582
Record published 2016-09-01
Record revised 2026-06-10 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries serial number

Catalogue Numbers

Catalogue numbers for Interventional Angiography System
Catalogue number Size Status
INFX-8000V In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
TrackX Trackx Technology Inc. 86
Trinias Shimadzu Corp. 54
Allura Xper FD Philips Medical Systems Nederland B.V. 21
Azurion Philips Medical Systems Nederland B.V. 19
LessRay Nuvasive, Inc. 16
Intelli-C Accessory Nrt – Nordisk Røntgen Teknik A/S 13
Pulse Nuvasive, Inc. 12
O-ARM® Medtronic Navigation, Inc. 11
Genoray Genoray Co., Ltd. 10
Fujifilm Healthcare Americas Corporation A.T.S. Applicazione Tecnologie Speciali SRL 7
Fujifilm Medical Systems U.S.A. Inc. A.T.S. Applicazione Tecnologie Speciali SRL 6
Stephanix A.T.S. Applicazione Tecnologie Speciali SRL 6

Showing 12 of 122. All products under Interventional Fluoroscopic X-Ray System

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252503 2026-04-30
K232298 2024-04-26
K200887 2020-04-15
K171194 2017-05-24

Recalls Naming This Product

9 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Interventional Angiography System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Canon Medical System, USA, Inc. 510(k) number 2026-08-04 Class II Process control Due to the fixing screws of ceiling movement gear in ceiling suspended arm that are part of the X-ray interventional systems may become loose. 10 systems
Canon Medical System, USA, Inc. 510(k) number 2022-01-31 Class II Software design The fluoroscopic dose rate might exceed the conforming value during biplane fluoroscopy. 16 systems
Canon Medical System, USA, Inc. 510(k) number 2021-12-20 Class II Vendor change control Abnormal images such as horizontal stripes may be displayed and recovery may not not be possible by restarting the system. The worst case scenario is an operator who is working without a workable image may remove a catheter from the patient 8
Canon Medical System, USA, Inc. 510(k) number 2021-02-05 Class II Software design The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles. 272 in total
Canon Medical System, USA, Inc. 510(k) number 2020-12-08 Class II Component design/selection System table may tilt because the bolts that fasten the vertical column and the table top tilting drive unit may become loose. Total of all Systems = 145 systems (U.S.)
Canon Medical System, USA, Inc. 510(k) number 2020-03-03 Class II Process control Bolts holding the longitudinal movement of catheterization tables may be loose, which may lead to table surface/top tilting. 46
Toshiba American Medical Systems Inc 510(k) number 2017-12-29 Class II Process control During an examination a device error occurred and the ceiling drive operation was disabled. It was found that the fastening bolts of the driving portion of the ceiling drive loosened cause the error. 29 units 2023-11-29
Toshiba American Medical Systems Inc 510(k) number 2015-08-14 Class II Radiation Control for Health and Safety Act When a fontal DA (Digital Angiography) acquisition was done, scattered x-ray came into the dose meter on the lateral side. As a result, the dose meter sent a minus value to the software. Consequently, the software defined the data as an “ab 4 2016-05-18
Toshiba American Medical Systems Inc 510(k) number 2015-03-11 Class II Device Design The table base rotational brake that holds the table top may not always be engaged when any force or side impact is applied to the table top. 28 units 2015-09-18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer