Image-Intensified Fluoroscopic X-Ray System, Mobile

1. Line Voltage: 220~230V, 50/60Hz 2. Output Power: 5.0kW 3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA 4. Radiography Mode - kV range:…

Registry build 21.09.26

1. Line Voltage: 220~230V, 50/60Hz 2. Output Power: 5.0kW 3. Fluoroscopy Mode – F-mode: 0.5~10mA – P-mode: 0.5~20mA – Boost mode: 30mA – DS mode: 10~30mA 4. Radiography Mode – kV range: 40~125kV, mA range: 20~100mA, mAs range: 0.8~200mAs 5. X-ray Tube – XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU 6. Detector – VIVIX-D 1212G (VIEWORKS), 12 x 12 inch

3manufacturers in China registered for this device type
2catalogue numbers in this listing

Who Else Makes It

Concentrated in Beijing (2), Shanghai (1).

Chinese manufacturers registered for FDA product code OXO
Manufacturer City Province Registered as Device types
GE Hangwei Medical Systems Co., Ltd. Beijing Beijing Specification developer 22
GE Healthcare (China) Co., Ltd. Beijing Beijing Specification developer 22
Siemens Shanghai, Medical Equipment Ltd. Shanghai Shanghai Contract manufacturer 10

Record

Regulatory record for Image-Intensified Fluoroscopic X-Ray System, Mobile
Listed by Ecotron Co., Ltd., South Korea
FDA product code OXO
Device type Image-Intensified Fluoroscopic X-Ray System, Mobile
Device class Class 2
Regulation 21 CFR 892.1650
Establishment Manufacturer
510(k) K180473
Record published 2018-03-29
Record revised 2018-07-06 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number
Storage Handling environment temperature 10 to 40 °C; Handling environment humidity 30 to 75 % RH; Storage environment temperature -10 to 70 °C; Storage environment humidity 5 to 95 % RH
Sizes Weight 250 kg; width 800 mm; length 1852 mm; height 1650 mm

Catalogue Numbers

Catalogue numbers for Image-Intensified Fluoroscopic X-Ray System, Mobile
Catalogue number Size Status
Anyview-240DR Weight 250 kg In distribution
Anyview-500DR Weight 250 kg In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
O-ARM® Medtronic Navigation, Inc. 16
Cios Select Siemens Shanghai, Medical Equipment Ltd. 3
Smart-C Turner Imaging Systems, Inc. 3
Zenition Philips Medical Systems Nederland B.V. 2
Broach Set SPX1 Ecential Robotics 2
Flourocsan InSight Hologic, Inc. 2
Genoray Genoray Co., Ltd. 2
3D Imaging Set SPX1 Ecential Robotics 2
Discovery GE Medical Systems, LLC 2
OEC Ge Hualun Medical Systems Co., Ltd. 2
Cios Alpha Siemens Healthcare Limited 1
System, X-RAY, Fluoroscopic, Image-Intensified Gemss Medical Systems Co., Ltd. 1

Showing 12 of 40. All products under Image-Intensified Fluoroscopic X-Ray System, Mobile

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer