Zenition
The Zenition 50 with image intensifier is a mobile X-ray imaging and viewing system. It is designed for medical use in healthcare facilities where X-ray imaging is needed
Who Else Makes It
Concentrated in Beijing (2), Shanghai (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GE Hangwei Medical Systems Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| GE Healthcare (China) Co., Ltd. | Beijing | Beijing | Specification developer | 22 |
| Siemens Shanghai, Medical Equipment Ltd. | Shanghai | Shanghai | Contract manufacturer | 10 |
Record
| Listed by | Philips Medical Systems Nederland B.V., Netherlands |
|---|---|
| FDA product code | OXO |
| Device type | Image-Intensified Fluoroscopic X-Ray System, Mobile |
| Device class | Class 2 |
| Regulation | 21 CFR 892.1650 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2019-04-04 |
| Record revised | 2024-01-29 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Latex | Contains natural rubber latex |
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Zenition 50 | In distribution | |
| Zenition 70 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| O-ARM® | Medtronic Navigation, Inc. | 16 |
| Cios Select | Siemens Shanghai, Medical Equipment Ltd. | 3 |
| Smart-C | Turner Imaging Systems, Inc. | 3 |
| Broach Set SPX1 | Ecential Robotics | 2 |
| Image-Intensified Fluoroscopic X-Ray System, Mobile | Ecotron Co., Ltd. | 2 |
| Flourocsan InSight | Hologic, Inc. | 2 |
| Genoray | Genoray Co., Ltd. | 2 |
| 3D Imaging Set SPX1 | Ecential Robotics | 2 |
| Discovery | GE Medical Systems, LLC | 2 |
| OEC | Ge Hualun Medical Systems Co., Ltd. | 2 |
| Cios Alpha | Siemens Healthcare Limited | 1 |
| System, X-RAY, Fluoroscopic, Image-Intensified | Gemss Medical Systems Co., Ltd. | 1 |
Showing 12 of 40. All products under Image-Intensified Fluoroscopic X-Ray System, Mobile
Recalls Naming This Product
5 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Philips Medical Systems Nederland B.V. | UDI-DI | 2025-09-29 | Class II | Process control | Over time some systems may experience loss of imaging functionality and/or poor image quality due to potential corrosion of the Image Intensifier Television (IITV) control board. | 29 units |
| Philips North America LLC | UDI-DI | 2025-02-25 | Class II | Labeling design | A wireless foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation. | |
| Philips North America LLC | UDI-DI | 2025-02-25 | Class II | Labeling design | A wireless foot switch pedal may get stuck in the active position when the user releases the pedal, resulting in the emission of unintended radiation. | |
| Philips Medical Systems Nederland B.V. | UDI-DI | 2024-10-07 | Class II | Under Investigation by firm | Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure. | 986 units (156 US, 29 Canada, 801 ROW) |
| Philips Medical Systems Nederland B.V. | UDI-DI | 2024-10-07 | Class II | Under Investigation by firm | Potential for the Mains Control Unit board fuse may blow out during system start-up or during a procedure. | 2,247 units (582 US, 84 Canada, 1,581 R.O.W.) |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.