Leksell Stereotactic System
Film Holder Tool
Who Else Makes It
Concentrated in Shaanxi (1), Guangdong (1), Hubei (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| OUR United Corporation | Xian | Shaanxi | Contract manufacturer | 2 |
| Masep Medical Science & Technology DEVELOPMENT(SHENZHEN)Co. | Shenzhen | Guangdong | Manufacturer | 2 |
| OUR SMD Medical (Wuhan) Co., Ltd. | Wuhan | Hubei | Contract manufacturer | 1 |
Record
| Listed by | Elekta Instrument AB, Sweden |
|---|---|
| FDA product code | IWB |
| Device type | System, Radiation Therapy, Radionuclide |
| Device class | Class 2 |
| Regulation | 21 CFR 892.5750 |
| 510(k) | K151159 |
| Record published | 2016-09-24 |
| Record revised | 2022-11-14 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1002964 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| GammaPod™ Breast Immobilization and Localization System | Xcision Medical Systems, LLC | 42 |
| Extend Frame system | Elekta Instrument AB | 23 |
| Clarity® | Elekta Solutions AB | 11 |
| Leksell Gamma Knife Icon | Elekta Instrument AB | 9 |
| Leksell Gamma Knife Perfexion/Icon | Elekta Instrument AB | 9 |
| Leksell Gamma Knife Perfexion/Icon | Elekta Solutions AB | 5 |
| Leksell Gamma Knife Icon | Elekta Solutions AB | 4 |
| GammaBeam | Best Theratronics Ltd. | 2 |
| Leksell Gamma Knife C 4 4C | Elekta Instrument AB | 2 |
| Isorad Detector, 15-25MV (-) 3m | Sun Nuclear Corporation | 2 |
| Leksell GammaPlan | Elekta Solutions AB | 2 |
| 15-25 MV Isorad Detector (3m Cable) | Sun Nuclear Corporation | 2 |
Showing 12 of 33. All products under System, Radiation Therapy, Radionuclide
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K173789 | 2018-03-30 |
| K173791 | 2018-02-09 |
| K160440 | 2016-04-20 |
| K151159 | 2015-10-29 |
| K151561 | 2015-08-04 |
| K133565 | 2014-05-09 |
| K120811 | 2012-05-24 |
| K092083 | 2009-09-22 |
| K063512 | 2007-03-05 |
| K061941 | 2006-08-21 |
| K061540 | 2006-07-05 |
| K051022 | 2005-06-01 |
| K984328 | 1999-05-21 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Elekta Inc. | 510(k) number | 2017-05-23 | Class II | Other | If the gantry module is replaced after original installation the configuration settings may be missing. The identified risk for this issue is electrical safety for technicians doing maintenance on the X-ray generator. | 2 | 2017-10-18 |
| Elekta Inc. | 510(k) number | 2016-04-19 | Class II | Use error | The latches of the frame adapter can be locked even if the locating pins of the frame adapter is not inserted into the corresponding holes in the coordinate frame. | 217 | 2021-07-16 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2018-06-27 | Class II | Software design | The margin tool in Leksell GammaPlan 11.1 systematically overestimates margin in certain areas of the volume. | 52 devices |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.