AlignRT Plus

The InBore imaging assembly is optional camera hardware for AlignRT Plus when used with bore-based linear accelerators. It contributes to a video-based three-dimensional surface imaging…

Registry build 21.09.26

The InBore imaging assembly is optional camera hardware for AlignRT Plus when used with bore-based linear accelerators. It contributes to a video-based three-dimensional surface imaging system that captures the patient’s skin surface before and during radiotherapy. Imaging does not require body markers or ionizing radiation.

The wider system combines camera units, processing software and a computer workstation. Surface matching during setup and treatment identifies changes in patient position relative to the prescribed treatment isocenter. The optional camera belongs to that surface-tracking system.

Listed Item

InBore Patient Imaging Assembly – Pinned

Treatment Monitoring Role

AlignRT Plus can supply position monitoring and respiratory gating signals, with user-selected surface points tracked in real time. During radiation delivery, the system can withhold the beam if the patient moves outside user-defined tolerances. The InBore camera extends the hardware configuration for a bore-based treatment environment.

8manufacturers in China registered for this device type
72catalogue numbers in this listing
11510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for AlignRT Plus
Listed by Vision RT Limited, United Kingdom
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Specification developer, Private-label distributor, Complaint-file establishment, Manufacturer
510(k) K203387
Record published 2021-09-23
Record revised 2022-12-15 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Distribution end date 2025-12-23

Catalogue Numbers

Catalogue numbers for AlignRT Plus
Catalogue number Size Status
HD CAM Gen 5 In distribution
AlignRT InBore In distribution
Calibration Cube Mk2 In distribution
InBore Power Repeater In distribution
Workstation Z4 – IGC TB ART In distribution
Real Time Coach In distribution
HP Z2 G9 workstation – AlignRT InBore In distribution
InBore Patient Imaging Assembly In distribution
HP Z2 G9 workstation – SimRT In distribution
Fujitsu M7010X In distribution
GateRT In distribution
DoseRT camera-computer interface box In distribution
HP Z2 G9 workstation – AlignRT Offline In distribution
Patient Data Workstation In distribution
Touchless4D In distribution
Horizon camera In distribution
ART Remote Control In distribution
InBore 60mm Calibration Plate Riser In distribution
Workstation Z2 In distribution
HP Z2 G9 workstation – AlignRT In distribution
OSMS 5.0 – TB 115V In distribution
AlignRT Offline Z2T In distribution
DoseRT workstation In distribution
InBore Fibre Hub In distribution
Real Time Coach In distribution
Mevion Interface Unit In distribution
AlignRT 6.3 In distribution
InBore System Cabinet In distribution
OSMS 5.0 In distribution
AlignRT InBore 7.0 In distribution
Power Distribution Unit In distribution
DoseRT isolation transformer In distribution
InBore Patient Imaging Assembly In distribution
Head Adjuster In distribution
DoseRT (software) In distribution
Calibration Plate In distribution
HD CAM In distribution
Lenovo P340 workstation In distribution
Workstation Z4 – OSMS TB In distribution
OSMS 5.1 115V In distribution
Varian ProBeam Hold – Switch Box In distribution
SimRT 7.2 In distribution
Horizon camera (close range) In distribution
Power Supply Unit (PSU) In distribution
GateCT In distribution
Workstation Z4 – IGC Gen GCT In distribution
Real Time Coach MK2 In distribution
HP Z2 G9 workstation – Patient Data Workstation In distribution
Workstation Z4 – ART In distribution
Workstation Z4 – IGB GEN ART In distribution
Real Time Coach (RTC) MK3 In distribution
Patient Data Workstation Z2T In distribution
SimRT 7.2 system In distribution
DoseRT camera (phase 2) In distribution
Workstation Z4 – OSMS CS In distribution
AlignRT 7.4 In distribution
HP Z2 G9 workstation – upgrades In distribution
Remote Control In distribution
OSMS 5.1 – TB 115V In distribution
AlignRT InBore 6.4 In distribution
OSMS Remote Control In distribution
Calibration Plate Narrow In distribution
Workstation Z4 – IGB CS ART In distribution
MMI 1.0 Breakout Box In distribution
AlignRT Withdrawn
AlignRT 6.0 Withdrawn
AlignRT 6.2 Withdrawn
AlignRT 6.1 Withdrawn
AlignRT Offline Withdrawn
OSMS 6.2 – 115V Withdrawn
DoseRT (software phase 2) Withdrawn
AlignRT Plus 6.x – 115V & 230V Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Vac-Lok™ Cushion Medtec LLC 100
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58
Gold Anchor Naslund Medical AB 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253012 2026-03-18
K243301 2025-05-19
K233622 2024-03-29
K231185 2023-06-23
K212583 2021-11-10
K203387 2021-03-04
K193431 2020-01-03
K181218 2018-08-07
K123371 2013-01-08
K072171 2007-10-01
K052682 2006-01-06

Recalls Naming This Product

5 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of AlignRT Plus
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Vision RT Limited 510(k) number 2018-08-24 Class II Software design RTInterface error in the event of an I/O error between the IGC PCB and the Framegrabber PCB 690 systens 2022-07-08
Vision RT Limited 510(k) number 2016-06-30 Class II Other Vision RT Ltd received three (3) reports from different sites that discovered the following issue, unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up for the Optical Su 47 2017-09-20
Varian Medical Systems, Inc 510(k) number 2016-06-23 Class II Software design Varian Medical Systems has received reports that unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up. This can occur when a user sets a different couch rotation from the 166 OSMS in US, 23 OSMO – International, 2018-08-24
Varian Medical Systems, Inc 510(k) number 2016-06-23 Class II Software design Varian Medical Systems has received reports that unintended changes were made to planned couch
parameters, specifically the couch rotation parameter, during patient set-up. This can occur when a user
sets a different couch rotation from the
21 AlignRT Plus in US, 1 International. 2018-08-24
Vision RT Limited 510(k) number 2014-10-15 Class II Software in the Use Environment Potential failure of AlignRT to assert interlock. 7 (Six Units distribited in the US and One in OUS.) 2016-05-10

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-06-30 Class II Other Vision RT Ltd received three (3) reports from different sites that discovered the following issue, unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up for the Optical Su 47 2017-09-20
2014-11-11 Class II Under Investigation by firm Potential use error when the external Gate Controller is turned ON after the Vision RT software has been opened. 55 2016-05-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer