Vac-Lok™ Cushion

Reusable, non-sterile, 75 x 105cm, 28L, nylon bag with indexing for arms-up positioning safe for use in 1.5T and 3.0T MR environments

Registry build 21.09.26
8manufacturers in China registered for this device type
100catalogue numbers in this listing
20510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (2), Beijing (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code IYE
Manufacturer City Province Registered as Device types
Guangzhou Tian Hong Medical Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 4
Klarity Medical & Equipment (GZ) Co., Ltd. Guangzhou Guangdong Contract manufacturer 3
Elekta Beijing Medical Systems Co., Ltd. Beijing Beijing Contract manufacturer 1
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
OUR United Corporation Xian Shaanxi Contract manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2
Jiangsu Rayer Medical Technology Co., Ltd. Wuxi Jiangsu Manufacturer 1

Record

Regulatory record for Vac-Lok™ Cushion
Listed by Medtec LLC, United States
FDA product code IYE
Device type Accelerator, Linear, Medical
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Specification developer, Manufacturer
510(k) K080072
Record published 2017-08-02
Record revised 2020-05-21 (version 8)

Specifications

Specifications
MRI safety MR Conditional
Prescription Prescription only
Label carries lot or batch number, manufacturing date
Storage Special storage condition: Keep away from sunlight
Sizes Length 50 to 260 cm; length 24 to 49.2 in
Distribution end date 2025-08-14
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Vac-Lok™ Cushion
Catalogue number Size Status
VLPLV02 In distribution
VLF15C In distribution
VLPLV02FC In distribution
VLE225 In distribution
VLG35 In distribution
VLPLV01FC In distribution
VLWGB03 In distribution
VLG40C In distribution
VLARM01C In distribution
VL37 In distribution
VLF15FC In distribution
VLJ20C In distribution
VLB40C In distribution
VLG26C In distribution
VLPLV01C In distribution
VLJ20 In distribution
VLB40 In distribution
VL0008 In distribution
VL14C25 In distribution
VLJ20FC In distribution
VLFBB01FC In distribution
VLA80C In distribution
VLFBB02FC In distribution
VL71FC In distribution
VL0017 In distribution
VLARM01 In distribution
VL0018 In distribution
VLH90C In distribution
VLFBB01C In distribution
VLE225C In distribution
VLTYS02CX In distribution
VLG26FC In distribution
VLFBB01 In distribution
VL04C In distribution
VLG40 In distribution
VLARM02C In distribution
VLPLV01 In distribution
VLPLV02C In distribution
VLTYS01CX In distribution
VLG35FC In distribution
VLG35C In distribution
VLARM01FC In distribution
VLF15 In distribution
VLARM02FC In distribution
VLPLV10C In distribution
VLPLV10FC In distribution
VLWGB03C In distribution
VLG40FC In distribution
MTVL0011 Withdrawn
MTVLH120C Length 200 cm Withdrawn
MTVL0008 Length 90 cm Withdrawn
MTVLARM02 Withdrawn
MTVLB40 Withdrawn
MTVLF15C Withdrawn
VLARM02 Withdrawn
MTVLPLV02FC Length 120 cm Withdrawn
MTVL06C Withdrawn
MTVLFBB01 Withdrawn
MTVLFBB01C Withdrawn
MTVL04 Withdrawn
MTVLG35FC Length 100 cm Withdrawn
MTVLG40 Withdrawn
MTVLE2.25 Withdrawn
MTVLG40C Length 100 cm Withdrawn
MTVLARM01FC Withdrawn
MTVLB40FC Withdrawn
MTVLJ20 Withdrawn
MTVLARM01 Withdrawn
MTVL0017 Length 49.2 in Withdrawn
MTVLFBB02FC Withdrawn
MTVL37 Withdrawn
VL04 Withdrawn
MTVLB40C Length 100 cm Withdrawn
VLPLV03C Withdrawn
MTVLARM01C Length 75 cm Withdrawn
MTVLE2.25C Length 50 cm Withdrawn
MTVLWGB03C Length 91.8 cm Withdrawn
MTVLF15 Length 70 cm Withdrawn
VLH120C Withdrawn
MTVLBRB01C Length 93.8 cm Withdrawn
MTVLTYS02CX Withdrawn
MTVLJ20C Length 70 cm Withdrawn
MTVL27B Length 260 cm Withdrawn
MTVLTYS01CX Length 24 in Withdrawn
MTVLG35C Length 100 cm Withdrawn
MTVL14C25 Withdrawn
MTVLPLV08 Length 25.5 in Withdrawn
MTVL14FC25 Withdrawn
MTVL04C Withdrawn
VLB40FC Withdrawn
MTVLF15FC Withdrawn
MTVLWGB03 Withdrawn
MTVLA80C Length 150 cm Withdrawn
MTVLG35 Length 100 cm Withdrawn
MTVLARM02FC Withdrawn
MTVLARM02C Length 75 cm Withdrawn
MTVLJ20FC Length 29.1 in Withdrawn
MTVL71FC Withdrawn
MTVLFBB01FC Withdrawn
MTVLG40FC Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Klarity Medical Klarity Medical Products, LLC 891
Orfit Industries Orfit Industries NV 680
Aquaplast RT™ Qfix 569
Fibreplast® Qfix 271
Bionix Radiation Therapy Bionix Radiation Therapy, LLC 115
Visicoil IZI Medical Products LLC 86
BodyFIX 3C-Medical Intelligence GmbH 84
AlignRT Plus Vision RT Limited 72
Fibreplast® Assure™ Open View Qfix 72
Accelerator, Linear, Medical PTW-Freiburg Physikalisch-Technische Werkstätten Dr. Pychlau GmbH 71
Thermoplastic Mask IZI Medical Products LLC 58
Gold Anchor Naslund Medical AB 58

Showing 12 of 1,611. All products under Accelerator, Linear, Medical

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K132908 2014-03-04
K974703 1998-03-10
K974700 1998-03-04
K954705 1996-01-05
K952729 1995-09-15
K952189 1995-08-09
K950075 1995-07-13
K951947 1995-07-12
K951679 1995-07-12
K951808 1995-07-06
K951717 1995-06-28
K950866 1995-05-30
K943199 1994-12-07
K944315 1994-11-22
K935411 1994-07-18
K935412 1994-07-18
K942282 1994-07-18
K935300 1994-07-18
K933227 1994-07-18
K935021 1994-04-07

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-05-12 Class II Component design/selection Potential for disengagement of the Varian Style Type-S Extension during patient repositioning. The risk associated with the disengagement of the extension could be a patient fall if the patient is not supported by clinical staff. 171 units 2021-03-25
2019-04-15 Class II Device Design There is a potential for movement of the Solstice Tilting Head Fixation System during patient setup and/or treatment. 28 units 2020-10-05
2009-08-31 Not classified Process control Some of the packages contain the incorrect mask style. 12 boxes 2012-03-07
2008-02-28 Not classified Labeling mix-ups Mislabeled: Fiducial markers were incorrectly labeled. They are marked (0.9x3mm cylindrical) Soft tissue gold markers, but contain (2mm spheres) Bone gold markers. 33/3-marker pouches 2008-07-02
2008-02-28 Not classified Labeling mix-ups Mislabeled: Fiducial markers were incorrectly labeled. They are marked (2mm spheres) Bone gold markers, but contain (0.9x3mm cylindrical) Soft tissue gold markers. 36/3-marker pouches 2008-07-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer