RayCare

RayCare 3.1 is a software-only oncology information system that supports healthcare professionals in managing cancer care. The filing describes modules for patient clinical data, care…

Registry build 21.09.26

RayCare 3.1 is a software-only oncology information system that supports healthcare professionals in managing cancer care. The filing describes modules for patient clinical data, care administration, clinical notes, workflow and task management, scheduling, and other healthcare-system functions.

Its intended role includes workflow and scheduling, clinical information, planning and treatment management across radiation, medical and surgical oncology. RayCare can transfer, store, convert and display patient data, but the filing states that it is not intended for diagnostic activities.

Clinical and Administrative Workflows

RayCare uses a client interface for user interaction and a server for processing and storage. The summary describes treatment-planning and delivery workflows, electronic patient charts, image review and archiving, and treatment-setup review.

5manufacturers in China registered for this device type
12catalogue numbers in this listing
15510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Fujian (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MUJ
Manufacturer City Province Registered as Device types
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
Masep Medical Science & Technology DEVELOPMENT(SHENZHEN)Co. Shenzhen Guangdong Manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for RayCare
Listed by RaySearch Laboratories AB (publ), Sweden
FDA product code MUJ
Device type System, Planning, Radiation Therapy Treatment
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Complaint-file establishment, Manufacturer
510(k) K200487
Record published 2021-09-30
Record revised 2023-05-18 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date
Distribution end date 2025-11-24

Catalogue Numbers

Catalogue numbers for RayCare
Catalogue number Size Status
5B SP1 In distribution
2024A SP1 In distribution
4.0 In distribution
2024A SP4 In distribution
4.1 Withdrawn
5A SP1 Withdrawn
3.0.1 Withdrawn
5.0 Withdrawn
2.3 Withdrawn
4.1.1 Withdrawn
3.0 Withdrawn
3.1 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
RayStation RaySearch Laboratories AB (publ) 29
System, Planning, Radiation Therapy Treatment Nucletron B.V. 17
Panther TPS Prowess, Inc. 14
Accuray Precision® Treatment Planning System Accuray Incorporated 7
Monaco Elekta Inc. 7
Eclipse Treatment Planning System for External Beam Radiation Therapy Varian Medical Systems, Inc 6
syngo.via RT Image Suite Siemens Healthcare Limited 5
Eclipse Treatment Planning System Varian Medical Systems, Inc 5
Corvus 09 Best Nomos 4
Monaco Elekta Solutions AB 4
XKnife® Integra Lifesciences Corporation 4
Philips Philips Medical Systems (Cleveland), Inc. 4

Showing 12 of 98. All products under System, Planning, Radiation Therapy Treatment

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252109 2025-12-22
K242992 2025-04-17
K240398 2025-04-04
K222312 2023-03-29
K220141 2022-04-15
K211867 2021-09-08
K210645 2021-06-29
K200569 2020-09-24
K200487 2020-06-10
K191384 2019-07-08
K190387 2019-06-19
K180379 2018-04-25
K171536 2017-06-27
K170355 2017-03-02
K160093 2016-04-08

Recalls Naming This Product

7 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of RayCare
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
RaySearch Laboratories AB (publ) 510(k) number 2026-05-20 Class II Under Investigation by firm Beam set delivery note issues in which there is potential data loss if the beam set delivery note is modified simultaneously and/or if a note is updated during a treatment session, the user is not notified of the change. 3 units
RaySearch Laboratories AB (publ) 510(k) number 2026-05-20 Class II Under Investigation by firm Beam set delivery note issues in which there is potential data loss if the beam set delivery note is modified simultaneously and/or if a note is updated during a treatment session, the user is not notified of the change. 3 units
RaySearch Laboratories AB (publ) 510(k) number 2023-09-12 Class II Under Investigation by firm An issue was found in RayCare 5B, 6A, including service packs, where values will not be visible for documents in a read-only state when opened outside the Documents workspace when using document fields configured with single- or multi-selec 2 sytems
RaySearch Laboratories AB (publ) 510(k) number 2023-07-17 Class II Under Investigation by firm An issue was found in Software RayCare 5A, 5B, 6A, including service packs, where an allergy warning against medication substance (drug ingredient) will not be displayed as expected under certain circumstances 1 install
RaySearch Laboratories AB (publ) 510(k) number 2021-06-08 Class II Under Investigation by firm Initial delivery positions will be set incorrectly when having setup beam(s) at the localization point. 5 units 2024-03-20
RaySearch Laboratories AB (publ) 510(k) number 2021-03-03 Class II Software design Patient related messages created in RayCare 3B, RayCare 4A will be lost when upgrading from RayCare 2 to RayCare 3B or later 1 unit
RaySearch Laboratories AB (publ) 510(k) number 2020-07-29 Class II Under Investigation by firm When performing offline image review in RayCare 2C, RayCare 3A and RayCare 3B an offline image review task will guide you to the image viewer with the treatment image related to the fraction and the planning image selected. When starting th

Recalls

38 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 22 units
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 0
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 10 units
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 119
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 0
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 8
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 0
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 0
2025-11-28 Class II Under Investigation by firm Potential for the invalidation for calculated radiation dose does not work as intended for certain Regions of Interest (ROIs). This issue occurs for some ROI(s) which have no contours and either have a material override defined, or are of t 0
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 26
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 13
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 6
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 0
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 1
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 3
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 2
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 3
2025-08-08 Class II Under Investigation by firm DICOM SOP Instance UID and Series Instance UID from RayGateway, i.e. the interface to Accuray’s iDMS, are not guaranteed to be unique. 49
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 1
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 0
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 0
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 0
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 1
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 0
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 1
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 6
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 32
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 0
2025-01-16 Class II Under Investigation by firm Inconsistency in the use of Density uncertainty in the RayStation functions Robust optimization, Robust evaluation and Compute perturbed dose for proton and light ion treatment plans when a HU-to-mass density CT calibration curve used in Ra 5
2024-03-28 Class II Software design Potential for reported SSD to be too high. 66 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 11 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 49 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 213 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 63 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 5 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 128 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 18 units
2024-03-28 Class II Software design Potential for reported SSD to be too high. 9 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer