System, Planning, Radiation Therapy Treatment

Oncentra External Beam 4.5.3/Oncentra Brachy v4.6

Registry build 21.09.26
5manufacturers in China registered for this device type
17catalogue numbers in this listing
1510(k) clearance
1recall

Who Else Makes It

Concentrated in Jiangsu (2), Fujian (1), Guangdong (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code MUJ
Manufacturer City Province Registered as Device types
Philips Healthcare (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 5
Manteia Technologies Co., Ltd. Xiamen Fujian Manufacturer 3
Masep Medical Science & Technology DEVELOPMENT(SHENZHEN)Co. Shenzhen Guangdong Manufacturer 2
Suzhou Linatech Medical Science AND Technology Co., Ltd. Suzhou Jiangsu Manufacturer 2
Varian Medical Systems China Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for System, Planning, Radiation Therapy Treatment
Listed by Nucletron B.V., Netherlands
FDA product code MUJ
Device type System, Planning, Radiation Therapy Treatment
Device class Class 2
Regulation 21 CFR 892.5050
Establishment Contract manufacturer, Specification developer, Manufacturer, Exporter
510(k) K121448
Record published 2018-03-20
Record revised 2018-07-06 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number
Distribution end date 2018-04-30

Catalogue Numbers

Catalogue numbers for System, Planning, Radiation Therapy Treatment
Catalogue number Size Status
170537-08 In distribution
170730 In distribution
170607-00 In distribution
170003-28 In distribution
Oncentra External Beam In distribution
170018-00 In distribution
Oncentra Brachy In distribution
170538-00 In distribution
170537-06 Withdrawn
170537-06 Withdrawn
170537-05 Withdrawn
170003-27 Withdrawn
170003-25 Withdrawn
170003-23 Withdrawn
170537-04 Withdrawn
170730 Withdrawn
170730 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
RayStation RaySearch Laboratories AB (publ) 29
Panther TPS Prowess, Inc. 14
RayCare RaySearch Laboratories AB (publ) 12
Accuray Precision® Treatment Planning System Accuray Incorporated 7
Monaco Elekta Inc. 7
Eclipse Treatment Planning System for External Beam Radiation Therapy Varian Medical Systems, Inc 6
syngo.via RT Image Suite Siemens Healthcare Limited 5
Eclipse Treatment Planning System Varian Medical Systems, Inc 5
Corvus 09 Best Nomos 4
Monaco Elekta Solutions AB 4
XKnife® Integra Lifesciences Corporation 4
Philips Philips Medical Systems (Cleveland), Inc. 4

Showing 12 of 98. All products under System, Planning, Radiation Therapy Treatment

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K132816 2014-06-13

Recalls Naming This Product

6 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of System, Planning, Radiation Therapy Treatment
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Elekta Inc. 510(k) number 2022-12-05 Class II Software design A reconstruction error may occur when using the Catheter Bending functionality in Applicator Modeling or Implant Modeling 336 systems
Elekta Inc. 510(k) number 2021-10-13 Class II Software design Under certain circumstances, there can be a difference between the planned and delivered dose of the two ovoid channels. 1072 devices
Nucletron B.V. 510(k) number 2017-08-10 Class II Software design Incorrect source step size may occur in the software plans 89 customer sites have the affected software 2020-11-20
Elekta Inc. 510(k) number 2016-12-23 Class II Software design Cross profile for Varian 60 degree wedge shows
“horns.”
433 2021-07-16
Elekta Inc. 510(k) number 2015-12-18 Class II Software design When using the option “Tumor Overlap Fraction” in VMAT planning it has been observed that in rare cases the system does include an organ at risk as target volume. This could result in open MLC, and open jaws in areas away from the target v 154 2021-09-15
Elekta Inc. 510(k) number 2015-05-21 Class II Other Incorrect dose calculation for Regions of Interest (ROIs) defined on a secondary image series. 351 2021-07-16

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer