FindrWIRZ
FindrWIRZ Guide Wire System
10manufacturers in China registered for this device type
3catalogue numbers in this listing
Who Else Makes It
Concentrated in Beijing (4), Jiangsu (3), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Beijing Bywave Sensing Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
| Shanghai Achieva Medical Suzhou Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Deepintec Scientific Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
Record
| Listed by | Atricure, Inc., United States |
|---|---|
| FDA product code | DQX |
| Device type | Wire, Guide, Catheter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1330 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K080364 |
| Record published | 2019-12-23 |
| Record revised | 2020-04-16 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Store in a cool, dry place |
| Packaging | Box, case of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 4005 | In distribution | |
| 40-05 | In distribution | |
| 40-05 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 625 |
| Cook | Cook Incorporated | 410 |
| Guidewire | Argon Medical Devices, Inc. | 173 |
| Medline Industries, Inc. | Medline Industries, Inc. | 151 |
| Guidewire | Galt Medical Corp. | 144 |
| Amplatz | Cook Incorporated | 128 |
| InQwire® | Merit Medical Systems, Inc. | 120 |
| Angiographic Guide Wire | Medtronic, Inc. | 94 |
| Glidewire | Terumo Corp. | 83 |
| Starter™ Guidewire | Lake Region Medical Limited | 82 |
| INT,Falcon Guide Wire | Shanghai Kindly Medical Instruments Co., Ltd. | 72 |
| GuideRight™ | St. Jude Medical | 69 |
Showing 12 of 525. All products under Wire, Guide, Catheter
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Sentreheart, Inc. | 510(k) number | 2016-09-29 | Class I | Under Investigation by firm | A complaint was received on September 27th, 2016 at a medical center in Germany for delamination and flaking of the PTFE lubricious coating on three FindrWIRZ Guidewire System.025 guidewires removed from their packaging hoops. | 132 worldwide distribution (98) of those units in US | 2017-03-01 |