Nipro AQUALiner™

SUPER ELASTIC HYDROPHILIC Ni-Ti ALLOY GUIDEWIRE

Registry build 21.09.26
10manufacturers in China registered for this device type
28catalogue numbers in this listing
2510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Beijing (4), Jiangsu (3), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DQX
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Beijing Bywave Sensing Medical Technology Co., Ltd. Beijing Beijing Manufacturer 2
Shanghai Achieva Medical Suzhou Co., Ltd. Suzhou Jiangsu Manufacturer 2
Deepintec Scientific Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for Nipro AQUALiner™
Listed by Nipro Medical Corporation, United States
FDA product code DQX
Device type Wire, Guide, Catheter
Device class Class 2
Regulation 21 CFR 870.1330
Establishment Complaint-file establishment, Exporter
Record published 2016-09-16
Record revised 2018-03-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 5, pack of 10
Sizes Length 150 to 260 cm; outer diameter 0.032 to 0.038 in

Catalogue Numbers

Catalogue numbers for Nipro AQUALiner™
Catalogue number Size Status
ALS+35260AS Length 260 cm In distribution
ALS+38260SS Outer Diameter 0.038 in In distribution
ALS+35150SS Length 150 cm In distribution
ALS+35150SR Outer Diameter 0.035 in In distribution
ALS+38150SR Length 150 cm In distribution
ALS+38150SS Outer Diameter 0.038 in In distribution
ALS+38180SR Length 180 cm In distribution
ALS+35260SR Outer Diameter 0.035 in In distribution
ALS+38180AR Outer Diameter 0.038 in In distribution
ALS+35180AR Length 180 cm In distribution
ALS+32150AR Length 150 cm In distribution
ALS+35260AR Length 260 cm In distribution
ALS+35150AR Length 150 cm In distribution
ALS+38150AS Outer Diameter 0.038 in In distribution
ALS+38180SS Length 180 cm In distribution
ALS+32260SR Outer Diameter 0.032 in In distribution
ALS+38180AS Outer Diameter 0.038 in In distribution
ALS+35180SR Outer Diameter 0.035 in In distribution
ALS+35180AS Length 180 cm In distribution
ALS+38260SR Length 260 cm In distribution
ALS+38260AS Length 260 cm In distribution
ALS+35180SS Outer Diameter 0.035 in In distribution
ALS+32260AR Outer Diameter 0.032 in In distribution
ALS+35260SS Length 260 cm In distribution
ALS+38150AR Outer Diameter 0.038 in In distribution
ALS+32150SR Outer Diameter 0.032 in In distribution
ALS+35150AS Outer Diameter 0.035 in In distribution
ALS+38260AR Outer Diameter 0.038 in In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 625
Cook Cook Incorporated 410
Guidewire Argon Medical Devices, Inc. 173
Medline Industries, Inc. Medline Industries, Inc. 151
Guidewire Galt Medical Corp. 144
Amplatz Cook Incorporated 128
InQwire® Merit Medical Systems, Inc. 120
Angiographic Guide Wire Medtronic, Inc. 94
Glidewire Terumo Corp. 83
Starter™ Guidewire Lake Region Medical Limited 82
INT,Falcon Guide Wire Shanghai Kindly Medical Instruments Co., Ltd. 72
GuideRight™ St. Jude Medical 69

Showing 12 of 525. All products under Wire, Guide, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K003394 2001-01-30
K001251 2000-07-07

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2012-07-27 Class II Equipment maintenance Nipro Medical Corporation, Miami, FL recalled their AquaLiner Hydrophilic Guidewire because the wires contain insufficient lubricity which causes them to get stuck in the housing and become nonfunctional. 400 2013-05-25
2012-07-27 Class II Equipment maintenance Nipro Medical Corporation, Miami, FL recalled their AquaLiner Hydrophilic Guidewire because the wires contain insufficient lubricity which causes them to get stuck in the housing and become nonfunctional. 1500 2013-05-25
2012-07-27 Class II Equipment maintenance Nipro Medical Corporation, Miami, FL recalled their AquaLiner Hydrophilic Guidewire because the wires contain insufficient lubricity which causes them to get stuck in the housing and become nonfunctional. 300 2013-05-25
2012-07-27 Class II Equipment maintenance Nipro Medical Corporation, Miami, FL recalled their AquaLiner Hydrophilic Guidewire because the wires contain insufficient lubricity which causes them to get stuck in the housing and become nonfunctional. 100 2013-05-25
2012-07-27 Class II Equipment maintenance Nipro Medical Corporation, Miami, FL recalled their AquaLiner Hydrophilic Guidewire because the wires contain insufficient lubricity which causes them to get stuck in the housing and become nonfunctional. 700 2013-05-25

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer