Prelude®

4 catalogue numbers from 10884450208257, listed by Merit Medical Systems, Inc., United States, under Wire, Guide, Catheter. 10 manufacturers in China are registered for this product code.

Registry build 21.09.26
10manufacturers in China registered for this device type
4catalogue numbers in this listing
22510(k) clearances naming this product code
9recalls on this code

Who Else Makes It

Concentrated in Beijing (4), Jiangsu (3), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DQX
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Beijing Bywave Sensing Medical Technology Co., Ltd. Beijing Beijing Manufacturer 2
Shanghai Achieva Medical Suzhou Co., Ltd. Suzhou Jiangsu Manufacturer 2
Deepintec Scientific Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for Prelude®
Listed by Merit Medical Systems, Inc., United States
FDA product code DQX
Device type Wire, Guide, Catheter
Device class Class 2
Regulation 21 CFR 870.1330
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2016-09-24
Record revised 2025-05-12 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 14

Catalogue Numbers

Catalogue numbers for Prelude®
Catalogue number Size Per pack Status
10884450208257 Guide Wire Diameter-0.021″ (0.53 mm) 5 In distribution
10884450208271 Guide Wire Diameter-0.025″ (0.64 mm) 5 In distribution
10884450208240 Guide Wire Diameter-0.021″ (0.53 mm) 5 In distribution
10884450208264 Guide Wire Diameter-0.025″ (0.64 mm) 5 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 625
Cook Cook Incorporated 410
Guidewire Argon Medical Devices, Inc. 173
Medline Industries, Inc. Medline Industries, Inc. 151
Guidewire Galt Medical Corp. 144
Amplatz Cook Incorporated 128
InQwire® Merit Medical Systems, Inc. 120
Angiographic Guide Wire Medtronic, Inc. 94
Glidewire Terumo Corp. 83
Starter™ Guidewire Lake Region Medical Limited 82
INT,Falcon Guide Wire Shanghai Kindly Medical Instruments Co., Ltd. 72
GuideRight™ St. Jude Medical 69

Showing 12 of 525. All products under Wire, Guide, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241521 2024-12-10
K230418 2023-10-28
K201595 2020-10-14
K170532 2017-07-21
K170933 2017-06-22
K170700 2017-04-06
K163575 2017-03-03
K142051 2014-12-17
K141295 2014-12-16
K140608 2014-09-12
K133230 2013-12-12
K131710 2013-07-29
K130588 2013-04-05
K123609 2013-01-16
K122089 2012-09-21
K120644 2012-09-19
K092303 2009-10-27
K072552 2007-12-14
K002289 2000-10-04
K973708 1997-12-19
K936032 1994-03-15
K921702 1992-09-21

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-05-08 Class II Process design Due to unsealed portions of pouches. 5,004
2014-04-14 Class II Process control Merit Medical Systems, Inc. is voluntarily conducting a recall due to a discrepancy between the carton and unit labeling for the Merit Laureate Hydrophilic 0.035″ 260 cm Guide Wire, catalog number LWSTFS35260EX, lot number K556399 (173 unit 186 2014-07-17
2014-04-14 Class II Process control Discrepancy between the carton and unit labeling for the Merit Laureate Hydrophilic 0.035″ 260 cm Guide Wire, catalog number LWSTFS35260EX, which has a straight tip and a stiff shaft. This lot was partially mixed with another lot of Laureat 173 2014-07-17
2010-06-28 Not classified Process control Guidewires have decreased lubricity at the proximal end, inhibiting proper operation. 20 units 2010-10-19
2010-06-28 Not classified Process control Guidewires have decreased lubricity at the proximal end, inhibiting proper operation. 437 units 2010-10-19
2010-06-28 Not classified Process control Guidewires have decreased lubricity at the proximal end, inhibiting proper operation. 199 units 2010-10-19
2010-06-28 Not classified Process control Guidewires have decreased lubricity at the proximal end, inhibiting proper operation. 40 units 2010-10-19
2010-06-28 Not classified Process control Guidewires have decreased lubricity at the proximal end, inhibiting proper operation. 140 units 2010-10-19
2010-06-28 Not classified Process control Guidewires have decreased lubricity at the proximal end, inhibiting proper operation. 128 units 2010-10-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer