Ritus
Dialysis Catheter Accessory,J/Straight Stainless Steel Guidewire,0.035"" x 27.7"" (0.889 mm x 70 cm)
Who Else Makes It
Concentrated in Beijing (4), Jiangsu (3), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Mehow Innovative (Huizhou) Ltd. | Huizhou | Guangdong | Contract manufacturer | 11 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Sunny Medical Device (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 11 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| Suzhou Zenith Vascular Scitech Limited | Suzhou | Jiangsu | Manufacturer | 6 |
| Beijing Bywave Sensing Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
| Shanghai Achieva Medical Suzhou Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 2 |
| Deepintec Scientific Co., Ltd. | Beijing | Beijing | Manufacturer | 2 |
Record
| Listed by | Mozarc Medical US LLC, United States |
|---|---|
| FDA product code | DQX |
| Device type | Wire, Guide, Catheter |
| Device class | Class 2 |
| Regulation | 21 CFR 870.1330 |
| Establishment | Specification developer, Manufacturer |
| 510(k) | K770977 |
| Record published | 2025-11-27 |
| Record revised | 2025-12-10 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Pack of 10 |
| Sizes | Length 27.7 in; outer diameter 0.035 to 0.038 in |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 8817231001 | Length 27.7 in | In distribution |
| 8813796001 | Length 27.7 in | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Arrow | Teleflex Medical LLC | 625 |
| Cook | Cook Incorporated | 410 |
| Guidewire | Argon Medical Devices, Inc. | 173 |
| Medline Industries, Inc. | Medline Industries, Inc. | 151 |
| Guidewire | Galt Medical Corp. | 144 |
| Amplatz | Cook Incorporated | 128 |
| InQwire® | Merit Medical Systems, Inc. | 120 |
| Angiographic Guide Wire | Medtronic, Inc. | 94 |
| Glidewire | Terumo Corp. | 83 |
| Starter™ Guidewire | Lake Region Medical Limited | 82 |
| INT,Falcon Guide Wire | Shanghai Kindly Medical Instruments Co., Ltd. | 72 |
| GuideRight™ | St. Jude Medical | 69 |
Showing 12 of 525. All products under Wire, Guide, Catheter
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Bard Peripheral Vascular, Inc. | 510(k) number | 2024-07-10 | Class II | Under Investigation by firm | Due to guidewires being manufactured incorrectly with the guidewires being mis-assembled within the hoop such that the proximal (stiff) end of the guidewire is located at the distal end of the hoop. Injury could occur if the user attempts t | 625 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.