Steerant™

Guidewire AGWSJ260 260CM Sngl-J TIP

Registry build 21.09.26
10manufacturers in China registered for this device type
3catalogue numbers in this listing
6510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Beijing (4), Jiangsu (3), Guangdong (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DQX
Manufacturer City Province Registered as Device types
Mehow Innovative (Huizhou) Ltd. Huizhou Guangdong Contract manufacturer 11
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Sunny Medical Device (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 11
Lepu Medical Technology (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Beijing Target Medical Technologies Inc. Beijing Beijing Contract manufacturer 7
Suzhou Zenith Vascular Scitech Limited Suzhou Jiangsu Manufacturer 6
Beijing Bywave Sensing Medical Technology Co., Ltd. Beijing Beijing Manufacturer 2
Shanghai Achieva Medical Suzhou Co., Ltd. Suzhou Jiangsu Manufacturer 2
Deepintec Scientific Co., Ltd. Beijing Beijing Manufacturer 2

Record

Regulatory record for Steerant™
Listed by Medtronic, Inc., United States
FDA product code DQX
Device type Wire, Guide, Catheter
Device class Class 2
Regulation 21 CFR 870.1330
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K232570
Record published 2024-03-04

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Storage Special storage condition: Do not expose to organic solvents (such as alcohol), ionizing radiation, or ultraviolet light.
Packaging Pack of 5
Sizes Outer diameter 0.89 mm; outer diameter 0.035 in; length 200 to 260 cm

Catalogue Numbers

Catalogue numbers for Steerant™
Catalogue number Size Status
AGWSJ260 Outer Diameter 0.89 mm In distribution
AGWSJ200 Length 200.0 cm In distribution
AGWDJ260 Outer Diameter 0.035 in In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 625
Cook Cook Incorporated 410
Guidewire Argon Medical Devices, Inc. 173
Medline Industries, Inc. Medline Industries, Inc. 151
Guidewire Galt Medical Corp. 144
Amplatz Cook Incorporated 128
InQwire® Merit Medical Systems, Inc. 120
Angiographic Guide Wire Medtronic, Inc. 94
Glidewire Terumo Corp. 83
Starter™ Guidewire Lake Region Medical Limited 82
INT,Falcon Guide Wire Shanghai Kindly Medical Instruments Co., Ltd. 72
GuideRight™ St. Jude Medical 69

Showing 12 of 525. All products under Wire, Guide, Catheter

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K250075 2025-06-13
K143316 2015-03-11
K140695 2014-06-12
K132623 2013-12-19
K101339 2010-08-31
K100470 2010-04-21

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2013-03-13 Class II Component change control Medtronic has identified an issue involving specific lot numbers of the Medtronic Archer 0.035 inch (0.89mm) Super Stiff Guidewire, Models ARCSJ200W, ARCSJ260W, and ARCDJ260W, where a change in the manufacturing process has been identified 27,682 devices 2014-02-06
2013-03-13 Class II Mixed-up of materials/components Medtronic has identified an issue with a specific lot of the Archer 0.035 inch (0.89mm) Super Stiff Guidewire, model ARCSJ200W, where the PTFE (Teflon) coating has the potential to separate from the wire during in-vivo use. 225 units 2013-11-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer