Swan-Ganz

Swan-Ganz Hi-Shore True Size Thermodilution Catheters

Registry build 21.09.26
1manufacturer
3catalogue numbers in this listing
2recalls on this code

Who Else Makes It

Registered in Shandong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code DYG
Manufacturer City Province Registered as Device types
Bioxin Medical Co., Ltd. Weihai Shandong Contract manufacturer 8

Record

Regulatory record for Swan-Ganz
Listed by Becton, Dickinson AND Company, United States
FDA product code DYG
Device type Catheter, Flow Directed
Device class Class 2
Regulation 21 CFR 870.1240
Establishment Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Manufacturer
510(k) K233824
Record published 2026-07-24

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: Store in a cool, dry place; Special storage condition: Special Storage Conditions (see IFU)
Packaging Case of 5
Sizes Length 110 cm; outer diameter 2.3 to 2.5 mm

Catalogue Numbers

Catalogue numbers for Swan-Ganz
Catalogue number Size Status
141F7 Recommended Guidewire Size [EN] = 0.025 inch (in) In distribution
131F7P Recommended Guidewire Size [EN] = 0.025 inch (in) In distribution
831F75P Minimum Introducer Size [EN] = 8.5 French (F) In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Arrow Teleflex Medical LLC 115
Transonic Transonic Systems, Inc. 12
Corodyn B. Braun Medical Inc. 10
Venos Occlusion Balloon Catheter Oscor Inc. 9
Swan-Ganz True Size Edwards Lifesciences Technology Sarl 9
Graftmaster Abbott Vascular 9
Swan-Ganz Edwards Lifesciences Technology Sarl 7
Pruitt Occlusion Catheter Lemaitre Vascular, Inc. 6
Swan-Ganz VIP Edwards Lifesciences Technology Sarl 3
Swan Ganz Catheter Edwards Lifesciences Technology Sarl 2
Swan-Ganz Ccombo Edwards Lifesciences Technology Sarl 2
Cook Cook Incorporated 2

Showing 12 of 23. All products under Catheter, Flow Directed

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Swan-Ganz
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Becton, Dickinson AND Company 510(k) number 2026-04-08 Class II Process change control Catheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss. 183

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-04-08 Class II Process change control Catheters may, due to a manufacturing process and material changes, leak/break from the (blue) proximal injectate lumen hub, which may lead to infection, medication loss, and/or blood loss. 53

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker